Danfoss AK-CC525A 084B8019 Danfoss AK-CC55C 084B4081 Electronic Expansion Valve Controller AK-CC55S 084B4082 AK-CC550 084B8020

Danfoss Electronic Expansion Valve Controller User Manual

Installation, Operation, and Maintenance Guide for AK-CC Series Controllers

1. Product Overview

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Danfoss Electronic Expansion Valve Controller. This device is engineered for precise control of electronic expansion valves within commercial air conditioning and refrigeration systems, ensuring optimal performance and energy efficiency.

1.1 Key Features

  • Versatile Compatibility: Compatible with multiple Danfoss AK-CC series models, including AK-CC525A (084B8019), AK-CC55C (084B4081), AK-CC55S (084B4082), and AK-CC550 (084B8020).
  • Commercial Application: Specifically designed for robust and reliable performance in high-demand commercial environments.
  • CE Certified: Bears CE certification, affirming compliance with European safety, health, and environmental protection standards.
  • Chemical-Free: Manufactured without high-concerned chemicals, promoting an eco-friendly choice for your HVAC needs.
  • Durable Construction: Crafted from high-quality, resilient materials to ensure long-lasting performance and reliability in demanding conditions.

2. Specifications

Feature Description
BrandDanfoss
Model NumbersAK-CC525A (084B8019), AK-CC55C (084B4081), AK-CC55S (084B4082), AK-CC550 (084B8020)
TypeElectronic Expansion Valve Controller, Air Conditioning Fitting, Air Conditioner Parts
ApplicationCommercial
CertificationCE
OriginMainland China
Power Supply (AK-CC550)230V AC, 50/60Hz, 5VA
Relay Output (AK-CC550)5(3)A
Power Supply (AK-CC55S/C)115-230V AC, 50/60Hz
Relay Output (AK-CC55S)8(6)A
Relay Output (AK-CC55C)8(6)A SSR 0.5A
Chemical ContentNone (High-concerned chemicals)

3. Setup and Installation

Proper installation is critical for the optimal performance, safety, and longevity of the controller. Always ensure all power to the system is disconnected before beginning any installation or wiring procedures.

3.1 Unpacking

Carefully remove the controller from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. Verify that all expected components are present. The package typically contains:

  • Electronic Expansion Valve Controller (specific model)
  • Installation Guide (refer to manufacturer's documentation for detailed instructions)
  • Mounting accessories (if applicable)
Danfoss AK-CC550 controller and packaging
Figure 3.1: Danfoss AK-CC550 (084B8020) controller and its packaging. The box indicates "Case Controller", "230V AC 50/60Hz", "PV19", "Singlepack 1 pcs", and "MADE IN SLOVAKIA". The controller itself is labeled "AK-CC 550 No. 084B8020 230V AC 50/60Hz 5VA Relay output 5(3)A".
Danfoss AK-CC55S controller and packaging
Figure 3.2: Danfoss AK-CC55S (084B4082) controller and its packaging. The box indicates "Case Controller", "115-230V AC", "Single Coil", "PV04", "Singlepack 1 pcs", and "MADE IN DENMARK". The controller itself is labeled "AK-CC55 Single Coil No. 084B4082 115-230V AC 50/60Hz Relay output 8(6)A".
Danfoss AK-CC55C controller and packaging
Figure 3.3: Danfoss AK-CC55C (084B4081) controller and its packaging. The box indicates "Case Controller", "115-230V AC", "PV02", "Singlepack 1 pcs", and "MADE IN DENMARK". The controller itself is labeled "AK-CC55 Compact No. 084B4081 115-230V AC 50/60Hz Relays 8(6)A SSR 0.5A".

3.2 Mounting

Mount the controller securely within a suitable electrical enclosure. Ensure the enclosure provides adequate ventilation to prevent overheating and protects the unit from moisture, dust, and extreme temperatures. Always adhere to local electrical codes and safety regulations during mounting.

3.3 Wiring Connections

Carefully follow the specific wiring diagrams provided for your controller model. Ensure all electrical connections are tight, secure, and correctly terminated. Incorrect wiring can lead to severe malfunction, damage to the unit, or electrical hazards.

Wiring diagram for Danfoss AK-CC550 controller
Figure 3.4: Terminal layout for Danfoss AK-CC550 controller. Key terminals include "Application 1", "Supply" (L, N), "AKV", "Alarm", "Comp", "Defrost", "Fan", "Light", "ADAP-KOOL®", "DI3", "PV19 SW.51", "230V AC", "Ethernet", and "Modbus".
Wiring diagram for Danfoss AK-CC55S controller
Figure 3.5: Terminal layout for Danfoss AK-CC55S controller. Key terminals include "115-230V AC" (L, N), "AKV", "DO2", "DO3", "DO4", "DO5", "DO6", "DI3", "PV04", "Display 1", "Display 2", "Option Module", and "Modbus".
Wiring diagram for Danfoss AK-CC55C controller
Figure 3.6: Terminal layout for Danfoss AK-CC55C controller. Key terminals include "115-230V AC" (L, N), "DO1", "SSR", "DO2", "DO3", "DO4", "PV02", "Display", and "Modbus".

Warning: Always consult a qualified electrician or HVAC technician for installation and wiring to prevent electrical shock, system damage, or voiding of warranty.

4. Operating Instructions

Once properly installed and wired, the controller is ready for operation. Specific programming and configuration details may vary significantly by model and the requirements of your particular refrigeration or air conditioning system. Always refer to the detailed product documentation provided by Danfoss for advanced settings and parameter adjustments.

4.1 Power On

After completing all wiring and safety checks, apply power to the unit. The display (if present on your model) should illuminate, indicating that the controller is active and performing its initial self-check.

4.2 Basic Operation

The controller automatically manages the electronic expansion valve based on its programmed parameters to optimize the refrigeration system's performance. It continuously monitors various system inputs (e.g., temperature, pressure) to adjust the valve opening. Monitor system pressures and temperatures to ensure correct operation and verify system stability.

4.3 Display and Navigation

Most Danfoss AK-CC series controllers feature a digital display and navigation buttons (typically 'SET', 'Up', 'Down', 'Enter') for viewing operational parameters, alarm statuses, and making necessary adjustments. Consult the specific model's user manual for detailed menu navigation, parameter descriptions, and adjustment procedures.

5. Maintenance

Regular and proactive maintenance is essential to ensure reliable operation, extend the lifespan of your controller, and maintain system efficiency.

  • Cleaning: Keep the controller's exterior free from dust, dirt, and debris. Use a soft, dry, lint-free cloth for cleaning. Avoid using abrasive cleaners, solvents, or any liquids that could seep into the unit.
  • Electrical Connections: Periodically inspect all electrical connections for tightness and any signs of corrosion or wear. Loose connections can lead to intermittent operation or system failure.
  • Firmware Updates: Check the official Danfoss website periodically for any available firmware updates. These updates may include performance enhancements, bug fixes, or new features. Follow the manufacturer's instructions carefully when performing updates.
  • Environmental Conditions: Ensure the operating environment for the controller remains within the specified temperature and humidity ranges. Protect the unit from direct sunlight, excessive heat, and high moisture levels.

6. Troubleshooting

This section provides basic troubleshooting steps for common issues. For complex problems, or if the issue persists after attempting these solutions, contact qualified service personnel or Danfoss technical support.

Problem Possible Cause Solution
Controller not powering on No power supply to the unit; incorrect wiring; tripped circuit breaker; internal component failure. Verify power supply to the controller. Check all power connections and ensure the circuit breaker is not tripped. Re-check wiring against the installation diagram. If the problem persists, contact technical support.
Electronic expansion valve not responding or operating incorrectly Incorrect valve connection; faulty sensor providing incorrect readings; programming error in controller parameters; mechanical issue with the valve itself. Inspect valve wiring for correct connections and integrity. Verify sensor readings on the controller display. Review and correct controller programming parameters. Check the valve for mechanical obstructions or damage.
Error code displayed on the unit Indicates a system fault, sensor issue, communication error, or other operational anomaly. Refer to the specific model's user manual for a comprehensive list of error codes and their corresponding troubleshooting steps. Address the root cause indicated by the code.
Inconsistent system performance (e.g., fluctuating temperatures) Improper controller tuning; sensor calibration issues; external system factors (e.g., refrigerant charge, airflow). Review and fine-tune controller parameters (e.g., superheat settings). Check sensor calibration. Investigate other components of the refrigeration system.

7. User Tips

  • Always ensure the power supply voltage and frequency match the controller's specifications (e.g., 115-230V AC or 230V AC, 50/60Hz) to prevent damage.
  • For optimal performance and longevity, install the controller in a location with stable temperature and humidity, away from direct heat sources, excessive vibration, or corrosive atmospheres.
  • Regularly back up any custom configurations or operational parameters, especially before performing firmware updates or significant system changes.
  • When replacing a controller, ensure the new unit is the correct model and has compatible firmware for seamless integration with your existing system.
  • Keep a record of all installation dates, maintenance activities, and any parameter changes made to the controller for future reference and troubleshooting.

8. Warranty and Support

For detailed warranty information, technical support, or service inquiries related to your Danfoss Electronic Expansion Valve Controller, please contact your authorized Danfoss distributor or visit the official Danfoss website. When contacting support, please have your purchase receipt, the specific product model number, and any relevant error codes readily available to facilitate faster and more efficient service.

Related Documents - AK-CC525A 084B8019 Danfoss AK-CC55C 084B4081 Electronic Expansion Valve Controller AK-CC55S 084B4082 AK-CC550 084B8020

Preview Danfoss AK-CC55 Single Coil Installation Guide
Installation guide for the Danfoss AK-CC55 Single Coil EEV controller. This document provides essential information on setup, wiring, technical specifications, operation, and troubleshooting for refrigeration and HVAC systems.
Preview Danfoss AK-CC55: Руководство пользователя для контроллера холодильного оборудования
Подробное руководство пользователя от Danfoss для контроллера холодильного оборудования AK-CC55. Охватывает функции, применение, технические характеристики и схемы подключения.
Preview Danfoss AK-PC 781A Capacity Controller: User Guide for Refrigeration Systems
Comprehensive user guide for the Danfoss AK-PC 781A capacity controller, detailing its features for refrigeration systems, including compressor and condenser control, heat recovery, and CO2 gas pressure management.
Preview Danfoss AK-PC 781A: Kapacitetsregulator med värmeåtervinningsfunktion - Användarguide
Användarguide för Danfoss AK-PC 781A kapacitetsregulator med värmeåtervinningsfunktion. Lär dig om installation, konfiguration och drift av detta avancerade styrsystem för kylapplikationer.
Preview Danfoss AK-PC 782A User Guide: Transcritical CO2 Booster Control
User guide for the Danfoss AK-PC 782A pack controller, detailing its application in transcritical CO2 booster systems, configuration, operation, and regulating functions for compressors and condensers.
Preview Kapacitetsregulator med varmegenvindingsfunktion AK-PC 781A
Comprehensive user guide for the Danfoss AK-PC 781A capacity regulator, a key component in ADAP-KOOL® refrigeration control systems. This manual details its application in compressor and condenser regulation, including advanced features like heat recovery, oil management, and CO2 pressure control. It covers system design, module overview, mounting, wiring, configuration via AK-Service Tool, and detailed operational functions for optimizing refrigeration performance and energy efficiency.