TIMEMORE Black Mirror Basic 3

Contents

TIMEMORE Black Mirror Basic 3 Digital Coffee Scale User Manual

Model: Black Mirror Basic 3

Brand: TIMEMORE

1. Introduction

Thank you for choosing the TIMEMORE Black Mirror Basic 3 Digital Coffee Scale. This sleek, smart, and lightweight weighing platform is designed to enhance your coffee brewing experience with precision and ease. It features a high-precision pressure sensor, multiple brewing modes, and a long-lasting battery, making it an essential tool for both beginners and experienced baristas.

TIMEMORE Black Mirror Basic 3 scale with text 'Weigh better. Sleeker. Smarter. Our most sophisticated scale yet.'
The TIMEMORE Black Mirror Basic 3 Digital Coffee Scale.
Key features of the Black Mirror Basic 3 scale including Coffee-to-Water Ratio, Improved Accuracy, Multifunction Switch, Real Time Flow Rate, 3 Timer Modes, 24h Long Battery Life, 0.1g Accuracy at ≤1kg.
Key features of the Basic 3 scale.

2. Safety Precautions & Important Notices

Please read the following notices carefully before using your Basic 3 scale:

  1. Use Basic 3 on a flat and stable surface to ensure accurate readings.
  2. Always use the included silicone pad to protect the surface of the Basic 3 and its internal components from heat, especially during brewing.
  3. Avoid fully depleting the battery. If the Basic 3 detects that its battery is fully depleted, it may require a low-current charge via a computer USB port before a standard adapter can be used.
  4. Using Basic 3 while charging may result in decreased accuracy. For best results, charge the device fully before use.
  5. When the timer is not activated, Basic 3 will idle for three minutes before entering standby mode. When the timer is activated, Basic 3 will idle for up to fifteen minutes before entering standby mode.
  6. To minimize the risk of water damage, avoid allowing liquid to enter the charging port or any gaps in the scale body. The device is IPX3 certified, meaning it is splash-resistant for brief periods only. Do not use for extended periods in high-temperature, high-humidity environments.
  7. Basic 3 is calibrated to exact specifications. Unauthorized disassembly may compromise its reliability and usability.
  8. Basic 3 was designed to brew great coffee. It is not intended for trade or commercial use.
Important notices for using the TIMEMORE Basic 3 scale, covering surface stability, silicone pad use, battery care, charging accuracy, idle/standby modes, water damage prevention, calibration, and intended use.
Important notices for safe and proper use.

3. Product Overview

3.1. Components and Controls

The Basic 3 features three capacitive touch keys and a multifunction slider for intuitive control.

Diagram showing the location of Mode/Power Button, Timer Button, Ratio Display, and Tare Button on the TIMEMORE Basic 3 scale.
Control buttons on the Basic 3 scale.
  • Mode / Power Button: Located on the side, this button is used to turn the scale on/off and switch between modes.
  • Timer Button: Controls the timer function.
  • Ratio Display: Shows the coffee-to-water ratio.
  • Tare Button: Used to zero out the weight.

3.2. Display Indicators

The LED display provides clear, easy-to-read information about your brewing process.

Diagram labeling the display indicators on the TIMEMORE Basic 3 scale: Time, Flow Rate, Weight, Ratio, Battery indicator, Sound indicator, Pourover mode indicator, Espresso mode indicator, and OZ indicator.
Display indicators and their meanings.
  1. Time: The maximum elapsed time is 59 minutes and 59 seconds (59:59).
  2. Flow Rate: The current pour rate, displayed in grams per second.
  3. Weight: Shows weights up to 2kg.
  4. Ratio: Can be turned on or off in both Regular and Pourover modes.
  5. Battery indicator: Displays the approximate charge remaining.
  6. Sound indicator: Indicates that audio feedback is enabled.
  7. Pourover mode indicator: Lights up when in Pourover mode.
  8. Espresso mode indicator: Lights up when in Espresso mode.
  9. OZ indicator: Indicates that the selected unit of measurement is ounces. By default, Basic 3 uses grams for weight measurements.

3.3. Design Features

  • LED Display: Clear, easy-to-read display with gentle lighting that is easy on the eyes.
  • Droplet-Inspired Design: Deep channels on the silicone mat catch and guide away spills.
  • Dual-Function Silicone Pad: Raised edges keep items stable. Flip the mat upside down to provide a cradle for your portafilter.
  • IPX3 Certified: A water-resistant design pairs with a precision-fit silicone seal to keep moisture out. Note: Splash-resistant for brief periods only.
  • Lightweight: At just 300g, Basic 3 is portable and fits anywhere.
Images showing the LED display, droplet-inspired design, and dual-function silicone pad of the TIMEMORE Basic 3 scale.
Visual overview of key design features.
Image highlighting the silicone gasket for IPX3 certification on the TIMEMORE Basic 3 scale.
IPX3 Certified for splash resistance.

3.4. Internal Technology

  • High-Precision Pressure Sensor: Accurate to 0.1g for fast and reliable weighing, even at heavy weights.
  • Electromagnetic Shield: A specialized shield protects against interference from magnetic catch cups or other electromagnetic sources, ensuring superior accuracy.
Exploded view diagram of the TIMEMORE Basic 3 scale showing internal components and electromagnetic shielding.
Internal components and electromagnetic shielding for accuracy.
TIMEMORE Basic 3 scale displaying weight with three coffee beans, illustrating its sensitivity.
High precision for accurate measurements.

4. Setup

4.1. Initial Charging

The Basic 3 is equipped with a 1600 mAh battery, providing up to 24 hours of continuous screen-on time. It takes approximately 3.5 hours to fully charge via USB-C. Ensure the device is fully charged before its first use for optimal performance.

Diagram showing the 1600 mAh battery, 24h screen-on time, 3.5h to full charge, and Type-C charging for the TIMEMORE Basic 3 scale.
Battery specifications and charging information.

4.2. Placement

Place the scale on a flat and stable surface. Use the included silicone pad on the weighing platform to protect it from heat and spills.

5. Operating Instructions

5.1. Power On/Off and Mode Switching

Use the multifunction slider on the side of the scale to toggle power and switch between modes. The modes cycle in the following order: Regular, Pourover, Espresso.

Image showing a hand operating the multifunction slider on the side of the TIMEMORE Basic 3 scale to switch modes.
Multifunction slider for power and mode selection.
Close-up of the multifunction slider on the TIMEMORE Basic 3 scale, showing 'M' for Mode, 'I' for Power On, and 'O' for Power Off.
Detail of the multifunction slider.

5.2. Overview of Brewing Modes

The Basic 3 offers three distinct timer modes optimized for different brewing methods:

  • Espresso Mode: Features Flow Rate, Auto Timer, and Auto Tare/Auto Wake.
  • Pourover Mode: Features Coffee-to-Water Ratio, Live Flow Rate, Auto Tare, and Intelligent Weight Detection.
  • Standard Mode: Features Coffee-to-Water Ratio, Live Flow Rate, Manual Timer, and Intelligent Weight Detection.
Diagram illustrating the three timer modes of the TIMEMORE Basic 3 scale: Espresso, Pourover, and Standard, along with their respective features.
Three timer modes for various brewing styles.

5.3. Pourover Mode

In Pourover mode, the scale assists with precise coffee-to-water ratio and live flow rate monitoring.

Diagram showing the steps for Pourover Mode on the TIMEMORE Basic 3 scale, including activating ratio function, placing brew gear, starting timer, and real-time ratio updates.
Pourover Mode instructions.
  1. Slide the side switch towards 'M' to enter Pourover mode. The Pourover icon will appear.
  2. Place your brew gear and coffee on the scale. Short-press the Timer button to start a 3-second countdown.
  3. After the countdown, the timer will show '---:---' and the weight will reset to [0.0]. Once you begin pouring, the scale will start the timer. Note: To account for the bloom, the timer will only stop automatically if the brew lasts more than 40 seconds.
  4. If you place the brewing equipment back on the scale after a short break, short-press the Timer button once to resume timing and weighing. Press it again to pause. Long-press the Timer button to reset the display and start a new pourover session.
Diagram showing the display in Pourover Mode with Elapsed Time, Pourover Mode Indicator, Flow Rate, Weight, and Coffee-to-Water Ratio labeled.
Pourover Mode display overview.

5.4. Espresso Mode

In Espresso mode, the scale automatically wakes from standby and tares when it detects a weight change greater than 50g.

Diagram showing the steps for Espresso Mode on the TIMEMORE Basic 3 scale, including entering the mode, automatic tare, and real-time display of weight, time, and flow rate.
Espresso Mode instructions.
  1. Slide the side switch towards 'M' to enter Espresso mode. The Espresso icon will appear, and the timer area will display: ESP.
  2. After 1 second, the scale is ready to use. Place your cup on the platform. Once detected, the scale will automatically tare.
  3. When a steady espresso flow is detected, the timer starts automatically, displaying weight, time, and flow rate in real time.
  4. When the brew is complete, remove the cup to stop the timer. The final values will blink on the display. Place the cup or wait 10 seconds for the scale to automatically reset.
Diagram showing the display in Espresso Mode with Elapsed Time, Flow Rate, and Weight labeled, and indicating when Espresso Mode is enabled.
Espresso Mode display overview.

5.5. Using the Ratio Function

The ratio function helps you achieve a consistent coffee-to-water ratio.

Diagram showing how to use the Ratio Function on the TIMEMORE Basic 3 scale, including turning on, taring, activating ratio display, adding coffee, and the display showing the ratio.
Instructions for using the Ratio Function.
  1. Turn on the scale. Place your pourover equipment on the platform and rinse the coffee filter. Then, press the Tare button to reset the weight to zero. Long-press the Ratio button to activate the coffee-to-water ratio display.
  2. Add ground coffee. Press the Ratio button to record coffee weight. The Ratio display blinks three times, then shows 1:0.0. Weight resets to 0.
  3. You are now ready to begin brewing. Press the Timer button to start the timer, short-press it to pause, long-press to reset it.
  4. During brewing, the ratio display will update in real time based on the amount of water added.

5.6. Toggling Units

By default, Basic 3 uses grams for weight measurements. To toggle between units (grams and ounces), quick press the Tare button 6 times.

6. Maintenance

  • Cleaning: Wipe the scale with a soft, damp cloth. Do not use abrasive cleaners or immerse the scale in water.
  • Water Damage Prevention: As the scale is only splash-resistant (IPX3), avoid direct exposure to water or using it in high-humidity environments for extended periods. Ensure no liquid enters the charging port or any gaps in the scale body.
  • Storage: Store the scale in a dry place away from extreme temperatures.

7. Troubleshooting

  • Scale stuck on starting screen: If the display remains fully lit or unresponsive, try turning the scale off and on again using the side slider. If the issue persists, ensure the battery is adequately charged.
  • Decreased accuracy during charging: As noted in the precautions, using the scale while charging may affect accuracy. For critical measurements, ensure the scale is fully charged and disconnected from power.
  • Scale enters standby too quickly: If the timer is not activated, the scale enters standby after three minutes. If the timer is active, it enters standby after fifteen minutes. This is normal behavior to conserve battery.
  • Inaccurate readings: Ensure the scale is placed on a flat, stable surface and that the silicone pad is correctly positioned. Avoid placing items that exceed the maximum load range (2000g).
  • Battery not charging: If the battery is fully depleted, it might require a low-current charge from a computer USB port before a standard adapter can be used.

8. Specifications

Technical specifications for the TIMEMORE Black Mirror Basic 3 scale, including dimensions, weight, accuracy, battery capacity, and load range.
Technical specifications of the Basic 3 scale.
AttributeValue
BrandTIMEMORE
ProductBlack Mirror Basic 3 Weighing Platform
ColorBlack / White
Weight~300g
Accuracy0.1g
Battery1600mAh
Dimensions140mm * 120mm * 20mm
Load Range0.2g - 2000g
Accuracy Variances0.5g (0.2-500g), 1g (500-1000g), 3g (1000-2000g)

*Though manufactured to meet stringent standards, individual units may vary.

9. User Tips

  • For better contrast and readability, some users prefer the black version of the scale.
  • The scale's precision is highly regarded, especially for espresso and pour-over methods.
  • The filter mode (Pourover mode) is particularly useful for timing and flow rate control.
  • The battery life is generally excellent, lasting 1-2 weeks for regular use.
  • Utilize the brew ratio measurement feature to consistently achieve your desired coffee flavor.

10. Warranty & Support

The Basic 3 comes with a limited one-year manufacturer's warranty. This warranty does not cover damage caused by wear and tear, misuse, or attempts to disassemble the device. For support or warranty claims, please refer to the contact information provided at the point of purchase or on the official TIMEMORE website.

A user manual in PDF format is available for download: View User Manual (PDF)


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.