1. Safety Instructions
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Warning: The charging station must be properly grounded (PE).
- Warning: Do not place flammable, explosive, or combustible materials, chemicals, combustible vapors, or other hazardous materials near the charging station.
- Warning: Keep the charging plug head clean and dry. If dirty, wipe it with a clean and dry cloth. It is strictly forbidden to touch the charging plug core by hand when it is charged.
- Warning: Do not use the charging station if the charging plug or cable is defective, cracked, worn, broken, or exposed.
- Warning: Do not attempt to disassemble, repair, or modify the charging station. Improper operation may cause damage, water leakage, electrical leakage, short circuit, or electric shock. Contact qualified personnel for repairs.
- Warning: Use with caution during thunderstorms.
- Warning: Children should not approach or use the charging station during charging to avoid electric shock.
- Warning: Do not drive the car while it is charging. Ensure the car is stationary. For hybrid cars, turn off the engine before charging.
- Warning: In case of emergency, press the emergency stop button immediately to cut off all input and output power.
- Warning: The use of the charging post is prohibited and the manufacturer should be contacted immediately if:
- The charging station shell is damaged.
- The charging cable is damaged, cracked, frayed, or broken.
- The charging station is struck by lightning.
- There are accidents or fires near the charging station.
- Water is present in the charging station.
- The charging cable is not long enough and an extension cable is needed (extension cables are not recommended unless specified by the manufacturer).
2. Product Overview
The Feyree EV Charger is designed for AC charging of electric vehicles. It features a simple design and is available in Type2, Type1, GB/T, and TS-NACS specifications. The charger supports both swipe card (RFID) and plug-and-play charging methods, incorporating multiple safety protection functions. It is dustproof and waterproof, making it suitable for outdoor operation.
Key Features:
- Dynamic Load Balancing (DLB): Automatically adjusts charging power to prevent electrical system overload by monitoring home appliance power consumption.
- High-Quality Material: Features 99.95% pure copper wire core cable and 5μ silver-plated charging pin for durability, conductivity, and corrosion resistance. TUV certified cable ensures safety.
- Smart App Control (Tuya Smart): Monitor charging status, set start/stop times, adjust charging power/current, and view charging data records via the free mobile app (Android/iOS).
- 8 Intelligent Safety Protections: Includes lightning-proof, leakage (Type B AC30mA + DC6mA), overvoltage, overheat, IP65 waterproof rating, UL94V-0 flame resistance, and overcurrent protection.
- Intelligent Temperature Control System: Ensures safe operation in various weather conditions, with automatic power-off at 85°C and restart at 65°C.
- 2.8-inch Color LCD Screen: Displays real-time charging information such as current, voltage, and power for easy monitoring.
- Schedule Charging: Set charging times during off-peak hours to save on electricity costs.
- Easy Installation: Designed for practical and intuitive wall-mounted installation, suitable for indoor and outdoor use.
Product Dimensions:

3. Specifications
The Feyree EV Charger is available in various power ratings and phase configurations. Below are the detailed specifications for the Type 2 IEC 62196-2 models.
General Specifications (Type 2 IEC 62196-2)
| Feature | 7.6kW 1 Phase | 11kW 3 Phase | 22kW 3 Phase |
|---|---|---|---|
| Charging Type | Type2 IEC62196-2 | ||
| Rated Voltage | 85V-264V | 380V±20% | |
| Rated Current | 8-10-13-16-20-25-32A | 8-10-13-16A | 8-10-13-16-20-25-32A |
| Input Frequency | 50Hz/60Hz | ||
| Charger Plug IP Rating | IP65 | ||
| Charger Box IP Rating | IP66 | ||
| Operating Temperature | -35°C ~ +55°C | ||
| Storage Temperature | -40°C ~ +80°C | ||
| Standby Power | <3W | ||
| Working Humidity | 5%~95% non-condensation | ||
| Cable Length | 5m | ||
| Leakage Protection | Type B AC30mA+DC6mA | ||
| LCD Display | 2.8 inch | ||
| Wireless Support | Wifi | ||
| Touchscreen | No | ||
Cable Specifications:
- 7.6kW 1 Phase: 3G 6mm²+1*0.5mm²
- 11kW 3 Phase: 5G 2.5mm²+1*0.5mm²
- 22kW 3 Phase: 5G 6mm²+1*0.5mm²
Control Box Functions:
- Leakage protection (restart recovery)
- Overvoltage and undervoltage protection (self-test recovery)
- Lightning protection
- Overcurrent protection
- Overheat protection
- Grounding protection
- RFID card function (can be set according to user needs)
- Appointment Time
- WIFI
Product Performance:
- Charging plug according to IEC 62196-2 standard
- Charging control box in accordance with IEC61851 control principle
- Insulation resistance: >1000Ω
- Terminal temperature rise: <50K
- Mechanical life: Charging Plug plugging and unplugging times (Non operating state) >10000 times
- External impact: Charging Station Plug can withstand the 1-meter drop and 2 tons of vehicle crushing
- Altitude: ≤2000m
- With emergency stop function




4. Setup and Installation
Before installation, ensure the area is clear of flammable materials and the equipment casing and cable are undamaged. The emergency stop button should be popped up (rotate clockwise to release if pressed).
Package Contents:

Installation Steps:
- Mounting the Bracket: Use the metal mounting bracket as a template to drill holes in the wall. Insert expansion tubes and secure the bracket with long screws. Refer to the product dimensions for appropriate installation height.
- Mounting the Charger: Hang the charger onto the fixed metal bracket. Secure the charger to the wall using additional screws underneath the charger.
- Install Charging Plug Holder: Install the charging plug holder in a convenient position near the charger.
- Connect Power: Connect the power supply to the charger. Ensure all connections are secure and the charger powers on correctly.
Wiring Diagrams:
Proper wiring is crucial for safe and efficient operation. Consult a qualified electrician for installation.


Installation Video:
This video demonstrates the unboxing, component overview, single-phase wiring diagram, and basic operation of the charger.
5. Operating Instructions
5.1. Charging Steps
- Standby Status: When the charging station is in standby mode, the LCD interface will display the device as ready for charging. The indicator light on the wallbox will be green and always on.

Charger in standby mode, ready for use. - Waiting for Card Swipe Status: Park your car, take the charging plug from its holder, and insert it into the electric vehicle connector. Ensure the plug is securely inserted. The device will then enter identity verification status.
- Start-up Device: Use an RFID card to authorize the charging station. Tap the RFID card on the induction area to start.

Using an RFID card to start charging. - Start Charging: Once authorized, the device will begin charging. The LCD interface will display charging status and parameters. The indicator light (for Wi-Fi function only) will show a green breathing effect.
- Stop Charging:
- The charging station will automatically stop charging when the vehicle is fully charged.
- In case of emergency, manually press the Emergency Stop button to cut off power.
- An RFID card can also be used to authorize stopping the charging process.
5.2. Key Operation Instructions
The charger features four buttons (O, A, D, T) for various settings and navigation.
- How to Set the Charging Current: When the charging plug is not inserted, press button 'A' on the panel to adjust the charging current. After using the RFID card to turn on charging, the device will output the corresponding current. The current setting range depends on the maximum charging power of your station:
- 7.6kW and 22kW versions: 8-10-13-16-20-25-32A
- 11kW version: 8-10-13-16A

Adjusting charging current using button 'A'. - How to Set Time Delay Charging: When the charging plug is not inserted, press button 'D' on the panel to set the delayed charging time. After swiping the card and turning on the charger, the device will start charging after the set delay. The delay can be set from 0 to 15 hours (each touch increases by one hour).

Setting delay time using button 'D'. - How to Set the Timing Charging: Press button 'T' on the panel to modify the timing charging. After swiping the card and turning on the charger, the device will charge for the set duration. After the time runs out, the charger will stop. The duration can be set from 0 to 15 hours (each touch increases by one hour).

Setting charging time using button 'T'.
5.3. Menu Navigation
- Accessing the Menu Page: Long press the 'O' button for 5 seconds to enter the settings menu. If your charger has an RFID function, you will need to swipe the RFID card after pressing for 5 seconds to enter the menu.
- Menu Page Basic Key Operation: Use the icon areas on the panel to navigate:
- Upward shift (increase parameter)
- Downward shift (decrease parameter)
- Enter (select option)
- Back (return to previous screen)
Note: When the charging plug is inserted, it is not possible to access charging plan and load balance settings. Unplug the charging plug to operate these functions.

Accessing the settings page and using RFID card. - Menu Options:
- Charge Plan: Adjust current, set delay start, set charge time.
- RFID Manage: Add or delete RFID cards.
- Charge Log: View the last 10 charging statuses for fault diagnosis.
- Setting:
- Hotkeys: Turn on/off the lock button to prevent unauthorized operation.
- CardID Check: Cancel or restart RFID card use.
- Reset Wifi: Clear network configuration.
- Ground Check: Turn on/off grounding (PE) detection.
- About Device: View device information (e.g., power, firmware version).
6. Dynamic Load Balancing (DLB)
The DLB function is an intelligent charging system that dynamically adjusts the charging station's power output based on the household's total circuit load. This prevents overloading and ensures electrical safety.
Working Principle:
- Total Current: Sets the maximum current capacity per phase (e.g., 80A) for the home circuit. Adjustable from 8A to 99A. Exceeding this value will trip the circuit breaker.
- CT Sensor: A monitoring device installed on the home main circuit that collects real-time total current data from all household electrical devices, including the charger.
- Charging Current: The real-time current used by the charger.
- Home Appliance: Total load of home appliances in the maximum load circuit, excluding the charging station. Calculated as "CT Sensor" - "Charging Current".
- Standby Current: Calculated as "Total Current" - "CT Sensor".
DLB Scenarios (Single Phase):

DLB Scenarios (Three Phase):

7. Smart App Control
The Feyree EV Charger can be controlled and monitored via the Smart Life (recommended) or Tuya Smart app. This requires the charger to have WiFi and Bluetooth functionality.
7.1. App Connection Steps:
- Download App: Download the "Smart Life" or "Tuya Smart" app from your mobile phone's app store.
- Enable Wireless: After downloading, open the app and ensure your phone's WiFi and Bluetooth are enabled.
- Add Device: Select "Add Device" in the app and follow the on-screen instructions to add your new charger. You will need to connect to your home WiFi network.
- Device Added: Once successfully added, the device will appear in your app.

7.2. App Features:
- Real-Time Monitoring: View charging status, voltage, current, power, and energy consumption.
- Remote Control: Start/stop charging, set delay times, and schedule charging.
- Adjust Current: Remotely adjust the charging current.
- Charging Schedule: Set weekly charging plans to utilize off-peak electricity hours and save money.

Setting charging periods to save money using the Tuya app. - Offline Control: The app can be used via Bluetooth hotspot if WiFi is unavailable (within 10 meters).

App connectivity via WiFi or Bluetooth hotspot.
8. Maintenance
- Regularly inspect the charging station and cable for any signs of damage, cracks, or wear.
- Keep the charging plug head clean and dry.
- Ensure the emergency stop button is functional and not stuck.
- For optimal performance and safety, ensure the charger is installed in a location that allows for proper heat dissipation. The unique waterproof and breathable membrane helps dissipate heat faster and extends the product's lifespan.

Unique waterproof and breathable membrane for heat dissipation. - The charger is designed for indoor/outdoor use in various climates, with sunscreen prevention and resistance to rainy environments.

Suitable for indoor/outdoor use in various climates.
9. Troubleshooting
This section provides solutions for common issues. If the problem persists, contact customer support.
| Fault Name | Reason for Failure | Recommendations |
|---|---|---|
| Over Voltage | AC input voltage is too high |
|
| Under Voltage | AC input voltage is too low |
|
| Over Current | AC input current is too high |
|
| Over TEMP | Charger internal temperature greater than 85°C |
|
| Elec leakage | Leakage is greater than the specified values (TypeA: AC20mA/AC30mA, TypeB: AC30mA+DC6mA) |
|
| Leakage self check | The sensor for detecting leakage is abnormal |
|
| PE Fault | Poor grounding or incorrect wiring |
|
| Err:cp | Charging plug CC/CP connection abnormality |
|
| Err:Reset | Reset button is pressed |
|
| Err:LoadBalance | Standby current + charging current < 8A |
|
Charging Status and Indicator Light:
| Charging Status | Green Light | Blue Light | Red Light | Description |
|---|---|---|---|---|
| Ready | Ever-bright | / | / | Power-up for self-test or reset |
| Connect | Flashing | / | / | Detection point 1 voltage is 9 ± 0.8 V. |
| Charging | / | Breathing | / | Detection point 1 voltage is 6 ± 0.8 V, relay closed |
| Finish | / | Ever-bright | / | Charging finished |
| Err:CP | / | / | Flash 1 time (0.5S) | Detection point 1 voltage is 9.8V<U<11.2V; 6.8V<U<8.2V; 12.8V<U or U<5.2V; relay opened |
| Under Voltage | / | / | Flash 2 time (0.5S) | Single-phase: voltage <85V, Three-phase: <304V |
| Over Voltage | / | / | Flash 3 time (0.5S) | Single-phase: voltage > 264V, Three-phase: > 457V |
| Elec Leakage | / | / | Flash 4 time (0.5S) | Relay is opened, it will be closed if re-powered after troubleshooting. |
| Over Current | / | / | Flash 5 time (0.5S) | The line current keeps at le+2<I≤le+4 for 5 seconds, the relay is opened, then restarted automatically after 10 seconds. It will permanently disconnect after three repetitions. At I> le+4, the relay is disconnected and the charging is finished. |
| Over Temp | / | / | Flash 6 time (0.5S) | Temperature > 85°C, the relay is opened. When the temperature is < 65 °C, charging restarts. |
| Err:Reset | / | / | Flash 7 time (0.5S) | Emergency stop button is pressed, the relay is opened, and it is allowed to close only after the fault is solved. |
| Err:LoadBalance | / | / | Flash 9 time (0.5S) | Standby current + charging current < 8A |
10. User Tips
- Review Instructions Thoroughly: Some users have noted that instructions can be unclear. Take your time to understand all steps, especially for app connection and Dynamic Load Balancing settings.
- Monitor Absorption Detection: If precise monitoring of energy absorption is critical for your use case, pay close attention to the charger's display and app data, as some users have found the absorption detection to be not very precise.
- App Connectivity: If you experience issues with the Smart Life (Tuya) app connection, ensure your home WiFi is stable and try re-pairing the device. Refer to the app connection steps in this manual.
- Power Compatibility: For 22kW chargers, ensure your electrical system supports 3 phases at 220V if you intend to use it at full power. Consult an electrician if unsure.
11. Warranty and Support
Two-Year Warranty:
Feyree offers a two-year warranty for original Feyree products.
Lifetime Technical Support:
For any product-related issues, please contact Feyree customer service. Providing pictures and videos can help expedite assistance.
E-mail: tina@feyree.com
Exclusions:
The warranty does not cover:
- Any product damage resulting from failure to follow recommended guidelines.
- Damage caused by unauthorized disassembly or repair by a non-designated service center.
- Products not purchased as original Feyree products.
- Any modifications or do-it-yourself alterations carried out without guidance from a licensed electrician.
12. FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and uses can radiate radio frequency energy, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user's authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirements. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antennas.