Universal Photovoltaic System Charger SA Series MPPT Solar Charge Controller

Contents

MPPT Solar Charge Controller User Manual

Model: SA Series

1. Introduction

Thank you for choosing the SA Series MPPT Solar Charge Controller. This intelligent controller is designed for photovoltaic systems, offering efficient and stable power generation with advanced Maximum Power Point Tracking (MPPT) technology. It supports various battery types and provides multiple layers of protection to ensure safe and reliable operation.

MPPT Solar Charge Controller with protection features listed

Figure 1: MPPT Solar Charge Controller highlighting protection features (Overheating, Overvoltage, Overcurrent, Overload, Undervoltage protection).

Key Features:

  • Intelligent MPPT charging for optimal power extraction.
  • Automatic identification of 12V/24V/36V/48V system voltage.
  • Compatible with a wide range of batteries: Ternary Lithium, Lithium Iron Phosphate, and Lead-Acid (Gel, Sealed, Flooded).
  • Multiple protection functions: Overheating, Overvoltage, Overcurrent, Overload, Undervoltage, Power failure, Lightning, Short circuit.
  • LCD backlight display for clear monitoring of system status.
  • Dual USB output for charging external devices.
  • Multiple operating modes: Charging, Light control, Test, Universal control, Manual control, Timing control, Light control + delay control.

2. Specifications

The SA Series MPPT Solar Charge Controller is available in various current ratings. Below are the general specifications and model-specific parameters.

Solar controller instruction manual with general specifications

Figure 2: General specifications for SA Series controllers.

General Specifications (SA Series)
ParameterValue
Input Voltage12V/24V/36V/48V; 96V (Auto-adapted)
Working Current60A / 80A / 100A / 120A / 150A
Working Temperature-25℃ ~ 55℃

Model-Specific Parameters

Detailed product parameters for SA48150A model

Figure 3: Detailed parameters for SA48150A model.

SA48150A Model Parameters
ParameterValue
Model NumberSA48150A
Overall Dimensions (Box Size)70 x 240 x 186 mm
Net Weight900g
Maximum Current Load120±10% 150±10%
Maximum Charging Current120±10% 150±10%
Appearance CharacteristicsBlue plastic shell + aluminum heat dissipation bottom plate

Other models like SA4840A, SA4860A, SA4880A, SA48100A, SA48120A have similar characteristics with varying current ratings and potentially different physical dimensions. For example, SA4880A/SA48100A have dimensions of 187x67x195mm and a net weight of 810g.

3. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your solar charge controller. Please follow these steps carefully.

3.1 Connection Method

Wiring diagram for solar system connection

Figure 4: Connection diagram showing solar panel, battery, and DC load connections.

The controller features multiple wiring ports, including dual USB interfaces, solar panel terminals, battery terminals, and load terminals. The enlarged wiring ports can connect up to 16mm wire.

Detailed product wiring diagram with labeled terminals

Figure 5: Detailed wiring diagram with labels for Dual USB interface, Solar + pole, Solar - polarized, Battery + pole, Battery - terminal, DC output port, Load - pole, Load + pole.

3.2 Connection Sequence

It is critical to connect the components in the correct order to prevent damage to the controller or other system components.

  1. Connect the battery first: Ensure the battery has sufficient voltage for the controller to identify the correct battery type (12V/24V/36V/48V auto-adaptation).
  2. Connect to the solar panel: Use a 15-23V solar panel for a 12V battery, a 30-40V solar panel for a 24V battery, a 45-60V solar panel for a 36V battery, and a 60-90V solar panel for a 48V battery. The voltage difference may cause overheating and damage to the controller if not within the recommended range. The total photovoltaic panel power should not exceed 80% of the controller's full load power.
  3. Connect the load at the end: Ensure correct battery voltage identification before connecting the load.

Note: If connecting to an inverter, connect the inverter directly to the battery terminals, not to the load terminals of the controller.

3.3 Installation Precautions

  • Install the controller as close to the battery as possible to avoid voltage drop caused by excessively long wires, which may affect normal voltage judgment.
  • This controller is suitable for all types of lead-acid batteries (including flooded, sealed, and gel) and lithium batteries (ternary lithium, lithium iron phosphate). For lithium batteries, manual adjustment of the overcharge voltage may be required. Do not use other battery types (such as nickel-metal hydride batteries).
  • This controller can only use photovoltaic panels as charging sources. Do not use DC or other power sources as charging sources.
  • The controller will generate heat when running. Please install the controller on a flat and well-ventilated surface to ensure proper heat dissipation.

4. Operating Instructions

The controller features an LCD display and intuitive buttons for easy operation and monitoring.

4.1 Display Interface and Buttons

Detailed description of LCD display icons and buttons

Figure 6: LCD display icons and button functions (RESET, MENU, ON/OFF).

  • Battery Icon: Shows battery charge status and voltage indication. Horizontal bars indicate charging status; static bars indicate current battery voltage. Displays battery voltage and discharge current, alternating every 5 seconds.
  • Solar Panel Icon: When displayed, it means the solar panel is charging. If flashing, charging has stopped.
  • Load Icon: When lit, the load is turned on. If flashing, discharge is stopped.
  • Time Display: Shows controller temperature, battery level percentage, or time in a 24-hour cycle for light control + delay mode.
  • Mode Control Area: Displays the currently selected operating mode.
  • Normal/Fault Status Display Area: "OK" indicates normal operation. "Fault" flashes for battery voltage abnormality, discharge current abnormality, or controller over-temperature. If controller temperature exceeds 75℃, "fault" flashes.

Buttons:

  • RESET (S1): Numerical "addition" adjustment and mode adjustment.
  • MENU (S2): Set/confirm button.
  • ON/OFF (S3): Numerical "subtraction" adjustment and forced start/stop. Long press to display solar panel voltage value.

4.2 Operating Mode Selection and Adjustment

Briefly press the "MENU" (S2) button to enter the operating mode selection. The corresponding mode icon will begin to flash. Briefly press the "RESET" (S1) button to switch between operating modes. Then, briefly press the "MENU" (S2) button again to close the mode selection.

Examples of different operating modes on the LCD display

Figure 7: Visual representation of the 6 available operating modes.

There are 6 mode options:

  1. Charging Mode: Under no circumstances can it be discharged.
  2. Light Control Mode: When the controller detects night, it will delay 10 minutes to start discharging. When the controller detects daytime, it will delay 10 minutes to stop discharging.
  3. Light Control + Delay Mode: When the controller detects night, it will delay 10 minutes to start discharging. When the controller detects daytime, it will delay 10 minutes to stop discharging according to the time set by the user.
  4. General Control Mode: In the absence of faults, the system remains in a constant discharge state.
  5. Manual Mode: Press the "ON/OFF" button to start or stop discharging.
  6. Timing Control Mode: Timing to turn on the discharge, timing to turn off the discharge.

Adjusting Delay Stop Time (Light Control + Delay Mode): When this mode is selected and confirmed, the delay stop time parameters will automatically pop up. Use S1 or S3 to adjust the value, and press S2 to confirm. Long press S2 to reset.

Adjusting Start and Stop Times (Timer Mode): Once you've selected "Timer" mode, the start time parameters will automatically pop up. Use S1 or S3 to adjust the values, and press S2 to confirm. Press and hold S2 to reset.

4.3 Charging Protection Parameters

The controller incorporates various charging protection mechanisms based on battery voltage.

Table of charging protection parameters for different battery voltages

Figure 8: Charging protection parameters including overvoltage recovery and high voltage protection thresholds.

Charging Protection Parameters
VoltageOvervoltage Recovery ChargingStart High Voltage Protection
12V13V14.8V
24V26V29.6V
36V39V44.8V
48V52V59.2V

Important:

  • When using a 12V battery, it can be charged if the battery voltage is lower than 13V, but it cannot be charged if the voltage is higher than 14.8V.
  • When using a 24V battery, it can be charged if the battery voltage is lower than 26V, but it cannot be charged if the voltage is higher than 29.6V.
  • When using a 36V battery, it can be charged if the battery voltage is lower than 39V, but it cannot be charged if the voltage is higher than 44.8V.
  • When using a 48V battery, it can be charged if the battery voltage is lower than 52V, but it cannot be charged if the voltage is higher than 59.2V.

Discharge Current Protection: When the discharge current is greater than 100%-150% of the rated current, the current protection will start immediately.

5. Maintenance

To ensure the longevity and optimal performance of your MPPT Solar Charge Controller, consider the following general maintenance guidelines:

  • Regular Inspection: Periodically check all wiring connections to ensure they are secure and free from corrosion.
  • Cleaning: Keep the controller's exterior clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Ventilation: Ensure the installation area remains well-ventilated to allow for proper heat dissipation. Do not obstruct the cooling fins.
  • Environmental Conditions: Avoid exposing the controller to extreme temperatures, direct sunlight, or excessive moisture.

Warning: Do not attempt to open or repair the controller yourself. Refer to qualified personnel for any servicing needs.

6. Troubleshooting

This section provides common failure phenomena, possible reasons, and methods of exclusion to help you diagnose and resolve issues.

Troubleshooting table for common product issues

Figure 9: Troubleshooting guide with failure phenomena, possible reasons, and solutions.

Troubleshooting Guide
Failure PhenomenonPossible ReasonsMethod of Exclusion
Sunny but not chargingPhotovoltaic panel open circuit or reverse connectionReconnect the photovoltaic panel
The load indicator is not litThe mode is set incorrectlyReset
Load indicator flashes slowlyThe battery voltage is too lowRecharge
Load indicator flashesLoad overcurrentReduce the load power
The controller does not light upBattery voltage too low/reverse connectionReplace battery/check reverse polarity

7. Warranty and Support

For any issues or further assistance during your usage, please do not hesitate to contact our customer service team. We are here to help you every step of the way.

Please refer to your purchase documentation for specific warranty terms and conditions. Keep your proof of purchase for warranty claims.