1. Product Overview
The UGREEN US3000 is a 12000mAh, 120W Uninterruptible Power Supply (UPS) designed to provide continuous power and protection for your Network Attached Storage (NAS) devices and hard disks. It features automatic identification, seamless power switching, and multiple safety protections to safeguard your valuable data against sudden power outages.


2. Safety Features
The US3000 UPS is equipped with a 9-fold safety shield to ensure stable power output and protect your devices even in adverse environments. These protections include:
- Overcharge Protection
- Over-discharge Protection
- Overcurrent Protection
- Short Circuit Protection
- Overvoltage Protection
- Over-temperature Protection
- Reverse Connection Protection
- Surge Protection
- Lightning Protection

3. Setup Instructions
Please follow these steps carefully to set up your UGREEN US3000 UPS with your NAS device.
Turn off NAS Device
Before connecting, ensure the NAS device you intend to connect is powered off and its original power adapter is unplugged.
Important Note:
Before turning off the NAS device, please stop all data transfer tasks to avoid data loss.
Connect to Mains Power
Connect the DC IN port of the US3000 UPS to the original power adapter of your NAS, and then plug the NAS power adapter into a wall socket.

Figure 4: Connecting UPS to Mains Power Connect NAS Device
Connect the DC OUT port of the US3000 UPS to the power input port of your NAS device. Also, connect a data communication cable (USB) from the UPS to the NAS data transfer port.

Figure 5: Connecting UPS to NAS Device 
Figure 6: UGREEN UPS connected to NAS Initial Activation and Binding
The product defaults to an energy-saving mode at the factory. Before use, it needs to be powered on to exit this mode. After product activation, it enters the charging state, and the white light will flash.
After connecting the power adapter, UPS, and AToC communication cable, power on the NAS. Then, access the UGREEN Cloud mobile/PC client, navigate to the Control Panel, select "Hardware and Power," and enter the "Uninterruptible Power System" section to complete the US3000 binding process.
Important Note:
This product does not include a power adapter. Please use the original power adapter that came with your UGREEN NAS device.
4. Operating Instructions
The UGREEN US3000 UPS is designed for automatic and seamless operation to protect your data.
- Automatic Identification: The UPS automatically identifies the power status and switches to battery backup when needed.
- Seamless Power Supply: In the event of a power failure, the UPS immediately activates to supply power to the NAS with 0s interruption, ensuring continuous operation.
- Data Protection: This immediate power supply ensures that data transmission is completed and provides sufficient time to save and safely shut down the NAS, protecting data integrity and hard disk safety.
- APP Control: Utilize the UGREEN Cloud mobile/PC client for strategic control over NAS power on/off functions.


5. Maintenance
- Proper Shutdown: When not using the product, always turn off the NAS device first, and then turn off the US3000 UPS. This sequence prevents data loss and potential NAS hard disk damage due to abrupt power interruption.
- Battery Longevity: To ensure optimal performance and longevity of the internal lithium battery, it is recommended to use the product within 3 months after purchase. Long-term storage without use may affect the battery's quality.

6. Troubleshooting
The US3000 UPS is designed to prevent common issues related to power interruptions. Here are some points to consider:
- Power Outage Impact: Sudden power failures can lead to data loss (unsaved data) and file system corruption, making files inaccessible or causing errors. The US3000 UPS is specifically designed to mitigate these risks by providing immediate backup power.
- Charging Indicator: If the white light on the device is flashing, it indicates that the product is in the charging state.
- No Power Adapter Included: Remember that the UPS does not come with its own power adapter. Always use the original power adapter supplied with your NAS device for proper operation.
- Energy-Saving Mode: If the device is not responding after initial setup, ensure it has been powered on to exit the factory default energy-saving mode.

7. Specifications
| Feature | Detail |
|---|---|
| Model Name | US3000 120W DC UPS |
| Model Number | 45617 |
| Battery Type | Lithium-ion battery |
| Power Input Interface | DC 5525 |
| Input | 12V-10A / 19V-7.9A / 20V-7A |
| Output | 12V-10A 120W Max |
| Voltage Conversion Time | 0s |
| Output Power | 120W Max |
| Rated Battery Energy | 43.2Wh (14.4V 3000mAh) |
| Rated Battery Capacity | 12000mAh (4x3000mAh) |
| USB Port | Data communication |
| Package Length | 45 cm |
| Package Width | 25 cm |
| Package Height | 30 cm |
| Package Weight | 3.8 kg |

8. User Tips
- Always ensure your NAS is properly shut down before disconnecting the UPS to prevent data corruption.
- For optimal battery health, try to use the UPS within three months of purchase and avoid prolonged periods of inactivity.
- If you experience any issues, double-check all cable connections and ensure the NAS power adapter is correctly connected to the UPS.
- Familiarize yourself with the UGREEN Cloud client for advanced control and monitoring of your UPS and NAS.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official UGREEN website or contact your retailer directly. Keep your purchase receipt as proof of purchase for any warranty claims.