1. Introduction
The HABOTEST HT93 is a new generation of high-performance smart digital multimeter designed for professional electricians, enthusiasts, and general household use. It features an intuitive display and function layout for a clearer and better user experience. This manual provides detailed instructions for the safe and effective operation of your HT93 multimeter.

2. Safety Information
WARNING:
- This instrument is designed to operate under specific conditions. Improper use may cause damage to the instrument or personal injury.
- Always be careful during operation. Do not perform operations not described in this manual or disregard safety instructions.
- Do not use the instrument if it appears damaged or is not functioning correctly.
- Ensure the battery compartment is securely closed before operation.
- This instrument is designed according to EN61010-2-030 and EN61010-2-033 CAT III 600V safety standards.

3. Package Contents
Please check the package contents upon receipt. If any items are missing or damaged, contact your vendor.
- 1 x HABOTEST HT93 Smart Multimeter
- 2 x Test Leads (Red and Black)
- 1 x User Manual (English)

4. Product Overview
Familiarize yourself with the components of the HT93 Smart Digital Multimeter:

- NCV Probe: Used for Non-Contact Voltage detection.
- Display Screen: High-resolution LCD for clear measurement data and function symbols.
- Function Switch Button (F/*): Cycles through measurement functions.
- Backlight Switch Button (H/): Activates/deactivates backlight.
- Power On/Off Button: Turns the device on or off.
- Data Hold / Flashlight Switch Button: Short press for Data Hold, long press for Flashlight.
- Input Socket (INPUT): Connects the red test lead.
- Common Socket (COM): Connects the black test lead.

5. Setup
5.1 Battery Installation
The HT93 multimeter requires 2 x 1.5V AAA batteries (not included). Follow these steps to install them:
- Ensure the multimeter is powered off and test leads are disconnected.
- Locate the battery compartment cover on the back of the device.
- Use a screwdriver to open the battery compartment.
- Insert two AAA batteries, observing the correct polarity (+/-).
- Close the battery compartment cover and secure it with the screw.

5.2 Connecting Test Leads
Connect the red test lead to the "INPUT" socket and the black test lead to the "COM" (Common) socket for most measurements.
6. Operating Modes and Functions
The HT93 features an auto-ranging function, simplifying operation. Press the Power On/Off button to turn on the device. Use the Function Switch Button (F/*) to cycle through different modes if needed.

6.1 Auto Range (Auto Testing)
When the instrument is set to AUTO mode, it automatically identifies and measures signals for voltage, resistance, and continuity, simplifying the measurement process.

6.2 AC/DC Voltage Measurement
The multimeter can measure both AC and DC voltages up to 600V. Connect the test leads to the circuit points you wish to measure. The device will automatically detect AC or DC voltage in Auto mode.
6.3 Non-Contact Voltage (NCV) Detection
In NCV mode, move the instrument's NCV sensing probe gradually closer to the area being tested. The device indicates the presence and strength of an electric field:
- Weak Electric Field: Green backlight lights up, screen displays "---L".
- Strong Electric Field: Red backlight lights up, rapid beeping sound, screen displays "---H".

6.4 Live Wire Detection
Select the LIVE mode. Connect the red test lead to the test point or insert it into the live wire socket. The device indicates live wire presence:
- Weak Signal: Green backlight illuminates, screen displays "---L".
- Strong Signal (Live Wire): Red backlight lights up, rapid beeping sound, screen displays "---H".

6.5 Resistance Measurement
The multimeter can measure the impedance of various resistive components and cables. Connect the test leads across the component to measure its resistance. The device will automatically select the appropriate range.

6.6 Continuity Testing
For resistance measurements less than 50Ω, the instrument will produce an audible beep, and the backlight will turn green, indicating continuity.

6.7 Data Hold / Two-color Backlight
Short press the Data Hold / Flashlight Switch Button to freeze the current reading on the display. Press it again to release. The display features a two-color backlight (green/red) for various indications.
6.8 LED Flashlight Illumination
Long press the Data Hold / Flashlight Switch Button to activate the LED flashlight. This feature is useful for illuminating contact points in dimly lit environments, making probe measurements more convenient.

6.9 Auto Shutdown
To conserve battery power, the instrument automatically powers off after approximately 15 minutes of no operation. This feature helps extend battery life.

6.10 Low Battery Indication
When the battery voltage drops below the normal operating level, a low battery icon will appear in the top right corner of the screen, reminding the user to replace the batteries.

7. Specifications
| Function | Range | Accuracy |
|---|---|---|
| DC Voltage | 2.000V/20.00V/200.0V/600V | ±(0.5%+3) |
| AC Voltage | 2.000V/20.00V/200.0V/600V | ±(1.0%+3) |
| Resistance | 2000Ω/20kΩ/200kΩ/2MΩ/20MΩ | ±(1.0%+3) |
| Counts | 2000 | |
| Display | HTN | |
| Auto/Manual Range | Auto | |
| Live Test | Yes | |
| NCV | Yes | |
| Phase Test | Yes | |
| Continuity | Yes | |
| Data Hold | Yes | |
| True RMS | Yes | |
| Bandwidth | 40~1kHz | |
| Low Battery Indication | Yes | |
| Auto Power Off | Yes | |
| Back Light | Yes | |
| Work Light | Yes | |
| Power Supply | 2 * 1.5V AAA Batteries (Not included) | |
| Product Weight | Approx. 97g | |
| Product Size | 136.2 * 44.5 * 32mm | |
| Safety Rating | EN61010-2-030 EN61010-2-033 CAT III 600V | |
| Pollution Level | 2 | |
| Altitude | <2000m | |
| Operating Temperature and Humidity | 0℃~40℃ (<18% RH, <10℃ non-condensing) | |
| Storage Temperature and Humidity | -10℃~60℃ (<70% RH, remove the battery) | |
| Temperature Coefficient | 0.1 accuracy/℃ (<18℃ or >28℃) | |
| Maximum Voltage Allowed Between Measuring End and Earth | 600V | |
| Over-range Indication | "OL" is displayed | |
| Input Polarity Indication | "-" sign is automatically displayed | |


8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the multimeter. Do not use abrasive cleaners or solvents.
- Storage: When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears to ensure accurate measurements.
- Probe Care: Inspect test leads for any damage before each use. Replace if insulation is cracked or wires are exposed.
9. Troubleshooting
- Device does not power on:
- Check if batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
- Inaccurate readings:
- Ensure test leads are properly connected. Check battery level. Verify the correct measurement mode is selected (though Auto mode should handle most). Ensure the operating temperature is within the specified range.
- "OL" displayed:
- This indicates an over-range condition. The measured value exceeds the maximum range of the selected function. Try a higher range if available, or confirm the circuit is within the device's capabilities.
- No continuity beep:
- Ensure the resistance is below 50Ω for the continuity beep to activate. Check test leads for proper connection and integrity.
10. User Tips
- Always double-check your connections before taking a measurement, especially when dealing with live circuits.
- Utilize the flashlight feature in poorly lit areas to ensure proper probe placement and safety.
- The auto-ranging feature is convenient, but for critical measurements, understanding the expected range can help confirm accuracy.
- Keep the probe storage slot on the back of the instrument clear for easy access and to prevent damage to the probes.
11. Warranty and Support