HABOTEST HT93

HABOTEST HT93 Smart Digital Multimeter User Manual

Model: HT93

Brand: HABOTEST

1. Introduction

The HABOTEST HT93 is a new generation of high-performance smart digital multimeter designed for professional electricians, enthusiasts, and general household use. It features an intuitive display and function layout for a clearer and better user experience. This manual provides detailed instructions for the safe and effective operation of your HT93 multimeter.

HABOTEST HT93 Digital Multimeter with features listed
Figure 1: HABOTEST HT93 Smart Digital Multimeter highlighting its key functions.

2. Safety Information

WARNING:

  • This instrument is designed to operate under specific conditions. Improper use may cause damage to the instrument or personal injury.
  • Always be careful during operation. Do not perform operations not described in this manual or disregard safety instructions.
  • Do not use the instrument if it appears damaged or is not functioning correctly.
  • Ensure the battery compartment is securely closed before operation.
  • This instrument is designed according to EN61010-2-030 and EN61010-2-033 CAT III 600V safety standards.
HT93 Package Contents and User Manual Safety Instructions
Figure 2: Excerpt from the user manual showing safety instructions.

3. Package Contents

Please check the package contents upon receipt. If any items are missing or damaged, contact your vendor.

  • 1 x HABOTEST HT93 Smart Multimeter
  • 2 x Test Leads (Red and Black)
  • 1 x User Manual (English)
HT93 Package Contents including multimeter, test leads, and user manual
Figure 3: Contents of the HT93 Smart Multimeter package.

4. Product Overview

Familiarize yourself with the components of the HT93 Smart Digital Multimeter:

Diagram of HT93 Multimeter with labeled parts: NCV Probe, Display Screen, Function Switch Button, Backlight Switch Button, Power On/Off Button, Data Hold Button, Flashlight Switch Button, Input Socket
Figure 4: Labeled diagram of the HT93 Smart Multimeter.
  • NCV Probe: Used for Non-Contact Voltage detection.
  • Display Screen: High-resolution LCD for clear measurement data and function symbols.
  • Function Switch Button (F/*): Cycles through measurement functions.
  • Backlight Switch Button (H/): Activates/deactivates backlight.
  • Power On/Off Button: Turns the device on or off.
  • Data Hold / Flashlight Switch Button: Short press for Data Hold, long press for Flashlight.
  • Input Socket (INPUT): Connects the red test lead.
  • Common Socket (COM): Connects the black test lead.
High-Resolution LCD Display and Probe Storage Slot on HT93 Multimeter
Figure 5: Detail of the high-resolution LCD display and convenient probe storage slot.

5. Setup

5.1 Battery Installation

The HT93 multimeter requires 2 x 1.5V AAA batteries (not included). Follow these steps to install them:

  1. Ensure the multimeter is powered off and test leads are disconnected.
  2. Locate the battery compartment cover on the back of the device.
  3. Use a screwdriver to open the battery compartment.
  4. Insert two AAA batteries, observing the correct polarity (+/-).
  5. Close the battery compartment cover and secure it with the screw.
Battery installation for HT93 Multimeter, showing compartment for 2x1.5V AAA batteries
Figure 6: Battery compartment for 2x1.5V AAA batteries.

5.2 Connecting Test Leads

Connect the red test lead to the "INPUT" socket and the black test lead to the "COM" (Common) socket for most measurements.

6. Operating Modes and Functions

The HT93 features an auto-ranging function, simplifying operation. Press the Power On/Off button to turn on the device. Use the Function Switch Button (F/*) to cycle through different modes if needed.

Icons representing multiple functions of the HT93 Multimeter: Auto Testing, AC/DC Voltage, Resistance, NCV, Live Wire, Data Hold/Two-color Backlight, Flashlight, Continuity Test, Auto Shutdown
Figure 7: Overview of the HT93's multiple functions.

6.1 Auto Range (Auto Testing)

When the instrument is set to AUTO mode, it automatically identifies and measures signals for voltage, resistance, and continuity, simplifying the measurement process.

HT93 Multimeter in Auto Range mode measuring voltage from an outlet
Figure 8: Multimeter operating in Auto Range mode.

6.2 AC/DC Voltage Measurement

The multimeter can measure both AC and DC voltages up to 600V. Connect the test leads to the circuit points you wish to measure. The device will automatically detect AC or DC voltage in Auto mode.

6.3 Non-Contact Voltage (NCV) Detection

In NCV mode, move the instrument's NCV sensing probe gradually closer to the area being tested. The device indicates the presence and strength of an electric field:

  • Weak Electric Field: Green backlight lights up, screen displays "---L".
  • Strong Electric Field: Red backlight lights up, rapid beeping sound, screen displays "---H".
HT93 Multimeter performing NCV detection, showing green and red backlight indications for weak and strong electric fields
Figure 9: Visual representation of NCV detection with backlight indicators.

6.4 Live Wire Detection

Select the LIVE mode. Connect the red test lead to the test point or insert it into the live wire socket. The device indicates live wire presence:

  • Weak Signal: Green backlight illuminates, screen displays "---L".
  • Strong Signal (Live Wire): Red backlight lights up, rapid beeping sound, screen displays "---H".
HT93 Multimeter performing Live Wire Detection, showing red backlight and 'H' indication
Figure 10: Live Wire Detection in action.

6.5 Resistance Measurement

The multimeter can measure the impedance of various resistive components and cables. Connect the test leads across the component to measure its resistance. The device will automatically select the appropriate range.

HT93 Multimeter measuring resistance of a component
Figure 11: Resistance measurement using the HT93 Multimeter.

6.6 Continuity Testing

For resistance measurements less than 50Ω, the instrument will produce an audible beep, and the backlight will turn green, indicating continuity.

HT93 Multimeter performing continuity test, showing green backlight and audible beep
Figure 12: Continuity testing with visual and audible indicators.

6.7 Data Hold / Two-color Backlight

Short press the Data Hold / Flashlight Switch Button to freeze the current reading on the display. Press it again to release. The display features a two-color backlight (green/red) for various indications.

6.8 LED Flashlight Illumination

Long press the Data Hold / Flashlight Switch Button to activate the LED flashlight. This feature is useful for illuminating contact points in dimly lit environments, making probe measurements more convenient.

HT93 Multimeter with LED flashlight illuminated
Figure 13: LED flashlight in use for illuminating work area.

6.9 Auto Shutdown

To conserve battery power, the instrument automatically powers off after approximately 15 minutes of no operation. This feature helps extend battery life.

HT93 Multimeter showing auto shutdown feature
Figure 14: Auto Shutdown feature for battery conservation.

6.10 Low Battery Indication

When the battery voltage drops below the normal operating level, a low battery icon will appear in the top right corner of the screen, reminding the user to replace the batteries.

HT93 Multimeter display showing low battery indication
Figure 15: Low battery indicator on the display.

7. Specifications

FunctionRangeAccuracy
DC Voltage2.000V/20.00V/200.0V/600V±(0.5%+3)
AC Voltage2.000V/20.00V/200.0V/600V±(1.0%+3)
Resistance2000Ω/20kΩ/200kΩ/2MΩ/20MΩ±(1.0%+3)
Counts2000
DisplayHTN
Auto/Manual RangeAuto
Live TestYes
NCVYes
Phase TestYes
ContinuityYes
Data HoldYes
True RMSYes
Bandwidth40~1kHz
Low Battery IndicationYes
Auto Power OffYes
Back LightYes
Work LightYes
Power Supply2 * 1.5V AAA Batteries (Not included)
Product WeightApprox. 97g
Product Size136.2 * 44.5 * 32mm
Safety RatingEN61010-2-030 EN61010-2-033 CAT III 600V
Pollution Level2
Altitude<2000m
Operating Temperature and Humidity0℃~40℃ (<18% RH, <10℃ non-condensing)
Storage Temperature and Humidity-10℃~60℃ (<70% RH, remove the battery)
Temperature Coefficient0.1 accuracy/℃ (<18℃ or >28℃)
Maximum Voltage Allowed Between Measuring End and Earth600V
Over-range Indication"OL" is displayed
Input Polarity Indication"-" sign is automatically displayed
Technical Parameter table for HABOTEST HT93 Smart Multimeter
Figure 16: Detailed technical specifications of the HT93 Multimeter.
Dimensions diagram of HT93 Multimeter: 136.2mm length, 44.5mm width, 32mm thickness
Figure 17: Physical dimensions of the HT93 Multimeter.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the multimeter. Do not use abrasive cleaners or solvents.
  • Storage: When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Battery Replacement: Replace batteries promptly when the low battery indicator appears to ensure accurate measurements.
  • Probe Care: Inspect test leads for any damage before each use. Replace if insulation is cracked or wires are exposed.

9. Troubleshooting

Device does not power on:
Check if batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
Inaccurate readings:
Ensure test leads are properly connected. Check battery level. Verify the correct measurement mode is selected (though Auto mode should handle most). Ensure the operating temperature is within the specified range.
"OL" displayed:
This indicates an over-range condition. The measured value exceeds the maximum range of the selected function. Try a higher range if available, or confirm the circuit is within the device's capabilities.
No continuity beep:
Ensure the resistance is below 50Ω for the continuity beep to activate. Check test leads for proper connection and integrity.

10. User Tips

  • Always double-check your connections before taking a measurement, especially when dealing with live circuits.
  • Utilize the flashlight feature in poorly lit areas to ensure proper probe placement and safety.
  • The auto-ranging feature is convenient, but for critical measurements, understanding the expected range can help confirm accuracy.
  • Keep the probe storage slot on the back of the instrument clear for easy access and to prevent damage to the probes.

11. Warranty and Support

For warranty information or technical support, please refer to the contact details provided by your retailer or the official HABOTEST website. Keep your purchase receipt as proof of purchase.


HABOTEST HT93 Smart Multimeter: All-in-One Auto-Ranging Voltage Tester with NCV and Live Wire Detection

HABOTEST HT93 Smart Multimeter: All-in-One Auto-Ranging Voltage Tester with NCV and Live Wire Detection

0:58 • 1280×1280 • feature_demo
HABOTEST HT93 Smart Multimeter: Auto-Ranging NCV Live Wire Detector with Flashlight

HABOTEST HT93 Smart Multimeter: Auto-Ranging NCV Live Wire Detector with Flashlight

0:58 • 720×720 • feature_demo
HABOTEST HT93 Smart Multimeter: All-in-One Auto-Ranging NCV Live Wire Voltage Tester

HABOTEST HT93 Smart Multimeter: All-in-One Auto-Ranging NCV Live Wire Voltage Tester

0:58 • 720×720 • feature_demo