1. Product Introduction
This module is a 3.2-inch graphical LCD display specifically designed for energy storage battery management systems (BMS). It features a 128x64 resolution dot-matrix blue screen LCD and has a built-in TTL communication interface. Users can view key parameters such as current battery voltage, current, and state of charge (SOC) via buttons, and also configure the protection board's CAN/RS485 protocol settings through the buttons.
Important Note: This 3.2-inch V19 Display is only compatible with JKBMS PB Series models: JK-PB1A16S10PV19, JK-PB1A16S15PV19, JK-PB2A16S15PV19, JK-PB2A16S20PV19, and JK-PB2A16S30PV19. It cannot be used with other BMS models.

2. Specifications
| Attribute | Value |
|---|---|
| Brand Name | JIKONG |
| Type | LIFEPO4 Battery BMS Display |
| Model | LCD-12864-TTL |
| Display Size | 3.2 inch |
| Resolution | 128x64 dot-matrix |
| Display Color | Blue screen |
| Communication Interface | TTL |
| Usage Scenario | Power BMS |
| Balance Function | Active Balanced BMS |
| Charge and Discharge Port | Common Port BMS |
| Charging Current | 10A |
| Function | Short Circuit Protection |
| Origin | Mainland China |
2.1 Mechanical Dimensions

3. Setup and Connection
3.1 Packing List
Ensure all components are present:
- 1 x 3.2 Inch Display
- 1 x Cable (50 cm)

3.2 Interface and Cables
The display module features two main interfaces:
- P1 Activation Switch Interface (GH1.25-6P)
- P2 User Interface (HY2.0-6P)

3.3 Connection Diagram
Connect one end of the provided cable to the user interface (P2) of the display screen and the other end to the TTL communication interface of the protection board. There is no need to distinguish the direction of the cable for connection.

3.4 Interface Pin Definition
| Connector | Pin No. | Description |
|---|---|---|
| P1 Activation Switch Interface (GH1.25-6P) | 1 | VIN: Connect to 12V power supply |
| 2 | RXD: Connect to protection board TX | |
| 3 | TXD: Connect to protection board RX | |
| 4 | GND: Ground connection | |
| 5 | K+: Connect to the positive terminal of the switch | |
| 6 | K-: Connect to the negative terminal of the switch | |
| P2 User Interface (HY2.0-6P) | 1 | K-: Connect to the negative terminal of the switch |
| 2 | K+: Connect to the positive terminal of the switch | |
| 3 | GND: Ground connection | |
| 4 | TXD: Connect to protection board RX | |
| 5 | RXD: Connect to protection board TX | |
| 6 | VIN: Connect to 12V power supply |
4. Key Operation and Display Instructions
4.1 Button Functions
The display features four buttons for navigation and control:
- K1: Power button / Menu button
- K2: Confirm button
- K3: Down / Up button
- K4: Back button

4.2 Initial Startup
After correctly connecting the display to the protection board, press the K1 power button to activate the protection board. To shut down the protection board, long press K1. The initial display interface after startup will show the main menu:
- GROUP
- PACKS
- SETTING
- ABOUT
4.3 Viewing Battery Group Information (GROUP)
From the main menu, use K3 to move the cursor to the “GROUP” option, then press K2 to display relevant information of the current battery group. This includes parameters like Voltage (Vtg), Current (Cur), State of Charge (SOC), and Capacity (CAP).

4.4 Viewing Individual Cell Information (PACKS)
Press K4 to return to the previous menu. From the main menu, select the “PACKS” option using K3 and press K2 to display the voltage of each cell in the current battery pack. Only 4 cells are displayed per page; press K3 to switch to the next page to view more cells.
4.5 Protocol Settings (SETTING)
From the main menu, select “SETTING” using K3 and press K2 to enter the protocol settings page. Here, you can use K3 to choose between setting the CAN or RS485 protocol. Press K2 to confirm your selection. Continue using K3 for navigation and K2 for confirmation to complete the protocol configuration.
4.6 About Information (ABOUT)
From the main menu, select “ABOUT” using K3 and press K2 to enter the About page. This page displays the current software version information of the display module (e.g., Ver:1.10).
5. Maintenance
- Keep the display clean and free from dust and moisture.
- Avoid exposing the device to extreme temperatures or direct sunlight for prolonged periods.
- Do not use harsh chemicals or abrasive cleaners on the screen or casing. Use a soft, dry cloth for cleaning.
- Ensure all cable connections are secure to prevent intermittent operation.
6. Troubleshooting
6.1 Common Issues
- Display not turning on:
- Check if the display cable is securely connected to both the display (P2) and the BMS TTL communication interface.
- Ensure the BMS is powered on and providing 12V to the display's VIN pin.
- Press the K1 power button firmly.
- Incorrect data displayed:
- Verify that the display is compatible with your specific JKBMS PB Series model (refer to Product Introduction).
- Check the communication cable for damage or loose connections.
- Ensure the correct protocol (CAN/RS485) is configured in the 'SETTING' menu if applicable.
- Buttons unresponsive:
- Ensure the display is powered on.
- Gently press the buttons to check for any physical obstruction.
7. User Tips
- For optimal readability, install the display in a location with adequate lighting but away from direct glare.
- When navigating menus, a short press on K3 moves the cursor, and a short press on K2 confirms the selection. K4 always acts as a 'Back' button.
- Regularly check the 'ABOUT' section to note the software version, which can be helpful for support inquiries.
8. Warranty and Support
For warranty information and technical support, please refer to the official JIKONG Smart BMS Store or contact your point of purchase. Keep your purchase receipt as proof of purchase.
A user manual in PDF format is available for download: JIKONG 3.2-inch Lattice Screen Operation and Maintenance Manual (PDF)