Olylife P90

Contents

Olylife P90 Terahertz PEMF Foot Massager Instruction Manual

Model: P90

1. Important Safety Warnings

This product is not a medical device and should not be used for disease treatment!

General Safety Guidelines:

  • Before using the instrument, please read this manual carefully and keep it in a safe place for future reference and inquiry.
  • Install, use, and operate the device correctly according to the instructions in this manual.
  • Do not disassemble or modify any parts of the machine.
  • Except for authorized personnel, it is strictly forbidden to open the cover and disassemble the main unit.
  • It is strictly forbidden for non-professionals to carry out repairs and modifications without authorization.
  • If there is any malfunction during operation, please contact support.

People Prohibited from Using this Device:

  • Patients with heart disease and high blood pressure.
  • Pregnant women and epilepsy patients.
  • Individuals with hypertension and diabetes.
  • Customers who are allergic to light.
  • People who have been working under strong light for a long time or have recently sunburned skin.
  • Customers undergoing short-term skin resurfacing.
  • Customers who are taking antioxidant or hormonal drugs.

2. Product Overview

The Olylife P90 is a high-end beauty instrument that combines advanced 808 semiconductor laser hair removal technology and YAG laser technology.

Key Advantages:

  • Laser Technology: Utilizes a world-class vertical stack laser with a long service life.
  • Efficient Cooling: Features an efficient and stable refrigeration system for continuous 24-hour operation. The contact sapphire cooling system ensures comfortable treatment by efficiently conducting cooling to the skin.
  • Smart Temperature Control: An intelligent water temperature control system prevents excessive water temperature, protecting the handle.
  • YAG Laser Handle: Provides a highly homogeneous light spot and uniform energy distribution for consistent and safe treatment effects.

The 808 nm semiconductor laser hair removal system uses a unique long pulse width laser to penetrate the epidermis to the hair follicle. The laser energy is preferentially absorbed by melanin in the hair, causing the hair to lose its ability to regenerate. The system's sapphire dynamic cooling technology anesthetizes the epidermis quickly, preventing burns and ensuring a painless, fast, and permanent hair removal effect.

The Picocare & Picowon technology treats pigmented diseases by finely smashing pigment with fast and powerful energy, which is then removed via lymphatic drainage. This shortens treatment times, reduces side effects, and improves success rates without damaging the dermis.

The device also incorporates the principle of selective photothermolysis, where shorter laser action times limit energy spread to surrounding tissues, protecting normal skin. The picosecond laser's ultra-short pulse width minimizes photothermal effects, enhancing the photomechanical effect for stronger curative results on pigmented lesions with shorter treatment times. Picosecond lasers break down pigment particles more thoroughly with less damage to surrounding tissue.

Magnetic Levitation Foot Massager with benefits
Magnetic Levitation Foot Massager highlighting whole body physiotherapy, major therapeutic effects, and major physiological muscles.
Boundless Energy Infusing the Entire Body
Benefits of the device including improving the body, relieving pain, strengthening resistance, and draining moisture.
Diagram showing how the foot massager relaxes the whole body
Diagram illustrating various benefits such as chill repellent, dehumidification, regulating sub-health, relaxing muscles, improving immunity, activating energy, and relieving pain.

3. Applications

3.1. 808 Semiconductor Laser:

  • Hair Removal: Effectively removes excess hair from various body parts, including armpits, beard, lip, bun, bikini line, and limbs.
  • Skin Rejuvenation: Helps shrink pores and whiten skin.

3.2. YAG Picosecond Laser:

  • 532 Laser Head: Suitable for treating red or tan tattoos, eyebrow tattoos, lip liner, eyeliner, and effectively lightens red or tan birthmarks and various superficial spots.
  • 1064 Laser Head: Effectively removes dark tattoos, eyebrow tattoos, lip tattoos, eyeliner, and traumatic pigmentation and freckles.
  • 755 Honeycomb Picosecond: Treats sunburn, freckles, chloasma, age spots, dry spots, dermal spots, and other stubborn pigmentation spots, including red and black moles.
  • 1320nm Black Face Baby Head: Used for skin rejuvenation, whitening, and shrinking pores.
Image showing various foot troubles the device can solve
The device aims to solve foot troubles and enhance blood circulation, addressing issues like fatigue from long hours at work, obesity-related discomfort, pain from extended standing/sitting, cold feet, sleep difficulties, and is suitable for elderly users.
Before and After Use comparison for foot conditions
Comparison of foot conditions before and after using the device, showing improvements from cold feet and poor blood flow to warm feet, improved immunity, and better circulation.

4. Specifications

General Product Parameters:

Parameter Value
Product Name Magnetic levitation energy meter
Supply Voltage 110V (AC220V; AC110V customizable)
Rated Frequency 50HZ
Power Supply 300W
Net Weight 3.30KG
Gross Weight 4.45KG
Material ABS (Shell material: metal)
Assembly Required No
Batteries Included No
Electronic No
Department Unisex-adult
Application Foot
Item Type Massage & Relaxation
Origin Mainland China
Product parameters diagram with dimensions
Product dimensions: 41cm (16.1in) length, 37.5cm (14.7in) width, 11cm (4.33in) height. Note: There is an error of 1-3cm for manual measurement.

808 Semiconductor Laser Specifications:

  • Laser Type: Semiconductor laser
  • Laser Wavelength: 808nm, 755nm, 1064nm
  • Working Frequency: 1-10Hz
  • Semiconductor Laser Power: 2000W

YAG Laser Specifications:

  • Laser Power: 500W
  • Output Frequency: 1-10Hz continuously adjustable
  • Maximum Single Pulse Output Energy: ≥1500mJ
  • Laser Wavelength: 1064nm, 532nm, 1320nm (755nm optional)
  • Operating Language: English

Cooling System:

  • Semiconductor refrigeration + water cooling + air cooling constant temperature cooling
  • Handle Temperature: -10 to -5°C

5. Setup

5.1. Unboxing and Initial Check:

  1. Carefully remove the instrument and accessories from the box. Retain packaging material for future transport or storage.
  2. Check the attachments against the provided attachment list (see below).
  3. Inspect for any mechanical damage.

Attachment List:

  • 1x Host unit
  • 1x 808 Laser Handle
  • 1x YAG Laser Handle
  • 2x Handle Brackets
  • 1x Water Injection Funnel
  • 1x Power Cord
  • 1x Foot Switch
Product packaging and included accessories
The product package includes the main device, remote control, instruction manual, and power cords with various plug types.

5.2. Installing Handle Bracket and Handles:

  1. Install the handle bracket onto the main unit.
  2. Attach the handles to the instrument and place them on the stand. Ensure the handle socket is fully tightened to prevent water leakage or block water flow.

5.3. Instrument Water Injection:

  1. Take out the water injection funnel and connect it to the water injection hole on the back of the instrument.
  2. Inject pure water or distilled water until water flows out of the overflow port. Do not use tap water or other types of water.

5.4. Power Connection:

  1. Connect the power cord to the device and a suitable power outlet.
  2. Plug the foot switch cable into the foot interface.
Side view of the device showing power input and switch
The side of the device features the power plug input and the main power switch.

6. Operating Instructions

6.1. Start-up Operation:

  1. Connect the power cord and turn on the main switch of the instrument.
  2. Turn on the emergency stop switch and then the key switch.

6.2. Interface Introduction:

After booting, the device will display the main interface with options. Click 'START' to enter the function selection interface.

  • Click 'DIOOE LASER' to enter the 808 operation interface.
  • Click 'PICOSECOND' to enter the small picosecond operation interface.
Close-up of the device's control panel
The control panel features buttons for Time, Energy, Start, and Return, along with indicators for energy levels (H, M, L).
Video demonstrating the basic operation of the device, including power-on, setting time and energy levels, and starting a session.

6.3. 808 Laser Operation Steps:

  1. Shave: Before operation, shave the treatment area, leaving 1-2mm of hair to facilitate light absorption.
  2. Apply Cold Gel: Apply a thin layer of cold gel to the operation part. The thickness should not be excessive, as it may affect the treatment effect.
  3. Adjust Treatment Parameters: Select appropriate treatment parameters based on the customer's skin color, hair thickness, and hair removal site. Adjust parameters according to the customer's comfort level.
  4. Operation Process:
    • Fit the handle probe to the skin to avoid light leakage and slowly slide it to operate.
    • Energy Adjustment: Start from the system's default energy. Reduce energy if the operator feels excessive heat; a slight thermal expansion indicates effective treatment.
    • Operation Time: Approximately 10-15 minutes for legs, 5-10 minutes for arms, 5 minutes for armpits, and 3 minutes for lip hair (for reference only; specific time depends on hair changes and treatment area size). The clinical endpoint is observed as redness, bulging of hair follicles, slightly curled hair, and thermal swelling of hair follicles.
  5. Post-Operation Cooling: After treatment, use the handle probe to cool the treated area for 3-5 minutes, or allow it to cool naturally.
  6. Clean Skin: Remove the gel and apply a hydrating product or body lotion.

6.4. YAG Laser Operation Steps:

  1. Parameters: Select the treatment band (755-1064-532). After selecting the mode, adjust the value.
  2. Energy Adjustment (mJ): The energy adjustment range is 100-2000mJ for 1064 mode, 100-2000mJ for 532 mode, and 100-2000mJ for 755nm. Gradually increase the treatment energy for 755 band, 532 band, and 1064 band up to 2000mJ.
  3. Wavelength Conversion: Click 1064nm to enter the 1064 operation wavelength interface, 532nm for 532nm, and 755nm for 755nm. Click 1064nm to enter the 1320 working wavelength interface.
  4. Frequency (Hz): Select frequency from 1, 2, ..., 10 Hz.
  5. Important Note: All parameter adjustments can only be made when the foot switch is disconnected. Any parameter adjustment while the pedal is depressed is not allowed. The footswitch is not allowed during setup.
  6. Treatment: After setting parameters, align the articulated arm's output port with the treatment area. Control the distance between the output port and the treatment part to adjust the spot diameter. Step on the foot switch to begin treatment.
  7. Operation Indications: This instrument is mainly used to remove skin exogenous and endogenous blue, black, and brown pigment lesions such as tattoos, eyebrow tattoos, freckles, butterfly spots, age spots, dermal spots, and for skin whitening and brightening.
  8. Treatment Interval: Treatments should be spaced 1-2 months apart to allow pigment particles to be absorbed.
  9. Number of Treatments: Multiple treatments are typically required for ideal results. The number varies based on pigment concentration, depth, composition, laser dose, and individual absorption. Exogenous pigments usually require more than 3 treatments, and endogenous pigments more than 5 treatments.

7. Maintenance

7.1. Instrument Maintenance Precautions:

  • Replace purified water or distilled water every 1 month.
  • Place the instrument in a clean, ventilated room with a temperature of 5-40°C and humidity not exceeding 80%, avoiding direct sunlight.
  • During use, ensure the instrument's vents are not blocked, and maintain at least a 5cm gap around the instrument.
  • Do not move the instrument far. Before transportation, drain all water from the instrument, tightly block all water holes, and use the original shock-absorbing packaging.

8. Troubleshooting

If you encounter any issues or malfunctions with your Olylife P90 device, please refer to the following general guidelines:

  • Check Power: Ensure the device is properly plugged in and the main power switch is on.
  • Water Level: Verify that the water level is adequate and that pure or distilled water is used.
  • Connections: Confirm all handles and the foot switch are securely connected.
  • Error Messages: Note any error codes or messages displayed on the screen.
  • Contact Support: If the problem persists after basic checks, please contact the seller or authorized service center for assistance. Do not attempt to repair the device yourself, as this may void the warranty and cause further damage.

9. User Tips

  • For optimal results, maintain a consistent treatment schedule as recommended for your specific application.
  • Always perform a patch test on a small, inconspicuous area before full treatment, especially when adjusting energy levels or using a new application mode.
  • Keep the treatment area clean and dry before applying gel and starting a session.
  • Hydrate your skin regularly, especially after laser treatments, to support recovery and maintain skin health.
  • Store the device in a cool, dry place away from direct sunlight to prolong its lifespan.

10. Warranty and Support

The instrument is guaranteed for 12 months from the date of purchase (with the receipt). Faults (non-artificial phenomena) will be repaired free of charge during the warranty period. For issues beyond the warranty period, maintenance will be provided, and the cost of spare parts and consumables will be charged according to company regulations (transportation costs are borne by the customer).

Free maintenance and warranty services are not provided for failures caused by the following personal reasons:

  • Failures caused by unauthorized disassembly and modification of this product.
  • Malfunctions caused by the use of hand tools not provided by the company.
  • Failures caused by careless use, beating, or falling.
  • Malfunction due to lack of reasonable maintenance.

For further assistance or to view the original user manual in PDF format, please refer to the User Manual (PDF).


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.