1. Safety Summary
This section contains important safety instructions that must be followed for operating, power, and storage environments. To ensure your safety, please read the following instructions before operation to ensure that the power supply is used in the best working environment.
1.1. Safety Guide
- Do not place heavy objects on the casing.
- To avoid severe impact or improper disposal that could cause damage to the machine, handle with care.
- Measures to prevent electrostatic discharge should be taken when connecting the instrument.
- Do not block or isolate the fan vent.
- Please do not open the machine unless you are a professional.
1.2. Power and Fuse Safety
- AC Input Voltage: 220V±10% 50Hz (for 110V input or 100V/220V manual switching models).
- The ground wire of the power cord must be connected to the ground to avoid electric shock.
- Ensure to use the correct fuse model before startup.
- To prevent fire, the fuse conforming to the model and rated value should be replaced.
- Before replacing the fuse, first cut the power to troubleshoot the causes for damaging the fuse.
1.3. Cleaning
- Firstly, cut the power before cleaning.
- Wet a soft cloth with warm detergent and water. Do not spray the detergent directly onto the machine.
- Do not use chemical or cleaning agents containing abrasive products, such as benzene, toluene, xylene, and acetone.
2. Product Overview
This series of DC regulated power supplies features a single output with an LED digital display. It can simultaneously display voltage, current, and power. The unit is portable and compact, allowing for continuous adjustment of voltage and current.
2.1. Main Features
- LED Digital Display: Virtually displays power output voltage, current, and power.
- Automatic Switching Regulator: Features an automatic switching regulator and flow regulator.
- Flexible Control: More flexible control with an output control switch.
- Multiple Protection: Includes over-voltage, over-current, over-power, and over-temperature protection. Protection thresholds can be set with special computer software.
- User-Friendly Interface: Convenient and fast operation interface.
- Low Noise Cooling: Temperature-controlled fan speed instrument ensures low noise and long fan life.

Figure 1: Main Features of the DC Power Supply

Figure 2: Built-in Protection Features
2.2. Product Video Overview
Video 1: Product overview, showing internal assembly and basic operation.
3. Setup and First Use
3.1. Front and Rear Panel Diagram

Figure 3: Front Panel Controls and Displays

Figure 4: Rear Panel Components
3.2. Connecting Power
- Input Power Demand: Refer to the specifications section for details on input power requirements.
- Check the Fuse: The proper fuse has been installed when the instrument is delivered. Please use the correct fuse model before startup.
- Connect Power Supply Line: Use the power cord supplied to connect the instrument to the AC power supply.
⚠️ In order to avoid electric shock, please confirm that the instrument has been properly grounded.
3.3. Power-on Check
Press the power switch on the front panel to connect the power. The backlight of the ON/OFF key will display red, indicating the power output is in the off status. Press the ON/OFF key again, and the backlight will display green, indicating the power output is now active.
4. Operating Instructions
4.1. Output Check
The output check ensures the instrument correctly responds to front panel operations and outputs the rated value. This includes checking the voltage output under channel load and the current output under short circuit conditions.
- Output Switch: To open the power output, press the ON/OFF key; the backlight will turn green. To close the output, press the key again; the backlight will turn red.
- Voltage Output Check:
- When the instrument is in empty load, open the power key and confirm the constant current knob is set to 0.
- Press the ON/OFF key to open the output. When the backlight turns green, the channel is in constant voltage output status (CV light is on). Check whether the voltage is adjusted to the maximum rated value from 0.
- Power Output Check:
- Open the power key.
- Adjust the power knob to set the output voltage to 3-5V, then press the ON/OFF key to cut the output.
- Use one wire to connect the output terminal of the front panel.
- Press the ON/OFF key to open the voltage. When the backlight turns green, the channel will be in constant current output status (CC indicator is on). Check whether the current is adjusted to the maximum rated value from 0.
4.2. Constant Voltage Output (CV Mode)
The power supply provides two kinds of power output modes: constant voltage output (CV) and constant current output (CC).
Under CV mode, the output voltage is directly controlled by two knobs for coarse and fine adjustment. For example, if the voltage is set to 16V, the current is set to the maximum rated value, and the load is 8Ω/300W. Since 16V/8Ω = 2A, which is less than the maximum rated value, the constant voltage outputs 16V and 2A power supply.
Operation Steps for CV Mode:
- Connect the Output Lead: Connect the instrument output terminal to the load as shown in the diagram below.
- Open Power Supply: Press the power key, and the instrument will enter the working status.
- Voltage Setting: Adjust the fine and coarse voltage adjustment knobs to set the desired voltage (e.g., 16V).
- Current Setting: Adjust the fine and coarse current adjustment knobs to set the constant current value as the maximum rated value.
- Open Output: Press the ON/OFF key (backlight will turn green), and the instrument will work under the constant voltage output mode.

Figure 5: Output Lead Connection Diagram
Hint: Under CV mode, if the load changes cause the output current to exceed the setting value, the instrument will switch to CC mode according to the set current, and the output voltage will be reduced proportionally. At this time, the current setting value will be increased, and CV output will be recovered.
4.3. Constant Current Output (CC Mode)
For example, if the voltage is set to 16V, the current is set to the maximum rated value of 5A (for model MY-305). The access load is 1Ω/300W. Because 1.5A = 5V < 16V and 16V/1Ω = 16A > 5A, the channel constant current will output 5V and 5A power.
Operation Steps for CC Mode:
- Connect Output Lead: Connect the instrument output terminal to the load in the mode shown in Figure 5.
- Open Power Supply: Press the power key, and the starting instrument will enter the working status.
- Voltage Setting: Adjust the fine and coarse voltage adjustment knobs to set the desired voltage (e.g., 16V).
- Current Setting: Adjust the fine and coarse current adjustment knobs to set the constant current value as the maximum rated value.
- Open Output: Press the ON/OFF key (backlight will be green), and the instrument will work under the constant current output mode.
⚠️ Incorrect connection may cause damage to the product or equipment connected to this product.
Hint: Under CC mode, if the load changes cause the output voltage to exceed the setting value, the instrument will switch to CV mode according to the current voltage, and the output current will be reduced proportionally. At this time, the voltage setting value may be increased, and CC output will be recovered.
5. Maintenance
5.1. Regular Check
During product use, to ensure the product achieves the best working conditions, please perform regular checks:
- Check if the power supply input socket is burned.
- Check if the power supply output terminal is loose.
5.2. Replacement of Fuse
- Take the power cord and remove the fuse box with a small screwdriver.
- Replace the fuse with one of the correct specifications.

Figure 6: Fuse Replacement Procedure
Fuse Specifications:
- 220V: F5A/250V
- 110V: F10A/250V (F5A/250V for 150W type)
6. Troubleshooting
For common issues, please refer to the "Operating Instructions" section for proper setup and connection. Ensure all cables are securely connected and the correct voltage/current settings are applied. If the device does not power on, check the fuse as described in the "Maintenance" section.
Hint: Please restart after shutdown. Ensure the interval between two startups is greater than 5 seconds.
7. Specifications
7.1. Performance Indicators
Voltage Output:
- Output voltage: 0V - maximum rated voltage
- Power effect: ≤0.1%+1mV
- Load effect: ≤0.1%+5mV
- Ripple noise: ≤30mVrms
Current Output:
- Output current: 0V - maximum rated voltage
- Power effect: ≤0.1%+5mA
- Load effect: ≤0.1%+5mA
- Ripple noise: ≤10mArms
Display Resolution:
- Voltage resolution: three-position: 10mV, four-position: 1mV
- Current resolution: three-position: 10mA, four-position: 1mA
- Power resolution: three-position: 10mW, four-position: 1mW
7.2. Operating Environment
- Indoor use
- Elevation: <2000m
- Environmental temperature: 5°C ~ 40°C
- Relative humidity: <80%
7.3. Storage Environment
- Environmental temperature: 5°C ~ 30°C
- Relative humidity: 60%
7.4. Power Input
AC 220V±10%, 50Hz (110V input or 100V/220V manual switching)
7.5. Product Size and Weight
- Dimensions: 265(D) x 125(W) x 145(H) mm
- Weight: About 2kg

Figure 7: Product Dimensions
8. Declaration of Toxic and Hazardous Substances
The following table indicates the presence of toxic or hazardous substances in the product components, according to SJ/T11363-2006 standards.
| Part Name | Lead (Pb) | Mercury (Hg) | Cadmium (Cd) | Hexavalent Chromium (Cr(VI)) | Polybrominated Biphenyls (PBB) | Polybrominated Diphenyl Ethers (PBDE) |
|---|---|---|---|---|---|---|
| Printed Circuit Module | X | O | O | O | O | O |
| Transformer | X | O | O | O | O | O |
| Connecting Line | X | O | O | O | O | O |
| Hardware Box | X | O | O | O | O | O |
| Power Line | X | O | O | O | O | O |
| Electric Material | O | O | O | O | O | O |
| Rubber Panel | O | O | O | O | O | O |
| Packing Material | O | O | O | O | O | O |
O: Indicates that the content of poisonous and harmful materials in the homogeneous materials is less than the limit specified in SJ/T11363-2006.
X: Indicates that the content of poisonous and harmful materials in the homogeneous materials exceeds the limit specified in SJ/T11363-2006.
9. Warranty and Support
9.1. Warranty Service
Thank you for choosing this power supply. Our company strictly implements the national three-warranty policy. If a product quality problem is not caused by artificial factors, you may repair, exchange, or return the product against the invoice or three-warranty certificate. If the project exceeds the warranty period, we will only charge for replacement parts.
Conditions Exempted from Warranty:
- Exceeding the effective term of the three-warranty period.
- Altering the three-guarantee certificate without authorization.
- Damages caused by improper use, maintenance, or safeguarding of the product.
- Product damages due to natural disasters, grid faults, or other force majeure causes.
- Accessories are not within the warranty scope.
- The product model or number on the three-guarantee certificate is not consistent with the physical commodity.
Products to be repaired should be packed and transported properly. In case of damage or missing items during transport, our company will not assume any responsibility.
The warranty card should be affixed with the seal of the after-sales unit and the date to ensure your rights. A blank warranty card template is provided in the original PDF manual for your reference.
For a complete warranty card and additional details, please refer to the official user manual PDF: View User Manual (PDF)
10. User Tips
- Power Plug Compatibility: This device is designed for 220V operation with a manual switch for 100V/220V. Please ensure you have the correct plug adapter for your region (e.g., European plug if applicable) and verify the voltage setting before connecting to power.