TahLiTech LT-300S

Rate this product if you’ve used it
Contents

TahLiTech LT-300S Multi-function Network Cable Tester

Model: LT-300S

1. Introduction

Thank you for purchasing the TahLiTech LT-300S Multi-function Network Cable Tester. This device is designed for efficient maintenance and installation of network cables, offering a comprehensive suite of testing capabilities. Please read this user manual carefully before use to ensure correct and safe operation.

1.1 Safety Precautions

  • Always comply with local electrical regulations when using this device. Avoid areas where electrical devices are prohibited (e.g., hospitals, gas stations).
  • Use only manufacturer-provided accessories to prevent damage and ensure safety.
  • Do not expose the device to humid, dusty, or high-temperature environments (above 50°C).
  • Use only batteries that meet the specified requirements.
  • Do not use this device to detect live power lines (e.g., 220V AC lines) as it may damage the device or pose a safety risk.
  • Avoid operating communication lines during thunderstorms to prevent lightning strikes.
  • The accessories are for use with this device only.
  • Avoid severe collisions or shaking during transportation and use.
  • Do not use the device in environments containing flammable gases.
  • When using the red laser source (Visual Fault Locator), do not look directly into the light as it may cause permanent eye damage. Turn off the laser and cover it with a protective cap when not in use.
  • Do not disassemble or repair the device yourself. Contact technical support if necessary.

2. Key Features

  • Display: 3-inch screen, 48*65mm.
  • Cable Tracing: Anti-interference digital cable tracer, supports UTP/STP shielded cable modes.
  • UTP/Continuity Test: Tests network cable sequence, detects open circuits, short circuits, and cross-connections. Also checks RJ45 connector crimping.
  • Cable Length Measurement: Measures open/short-circuited network cables from 1 to 600 meters with an accuracy of Cable length x 3% ± 1m.
  • Port Flashing: Quickly locates ports on switches or routers and identifies port speeds (100/1000M).
  • PoE Testing: Detects PoE power supply protocols (IEEE802.3BT/AT/AF/Non-standard), power supply voltage, line pair, pair polarity, and real-time power (0-90W) when connected to a PD load device.
  • PD Power Detection: Detects standard or non-standard PoE, supports 24V and 48V PoE.
  • Optical Power Meter (Optional): Supports wavelengths 850/980/1270/1300/1310/1490/1550/1577/1625/1650nm. Power range: -70 to +6dBm.
  • Visual Fault Locator (Optional): 10mW power output, 650nm wavelength, stable and pulse modes. Emits visible red laser to detect fiber optic breaks, cracks, bends, and other faults.
  • Power Source: Powered by 3.7V 2000mAh lithium-ion rechargeable batteries for both Emitter and Receiver.

3. Included Accessories

  • Emitter Unit
  • Receiver Unit (Cable Tracer)
  • RJ45 Cable
  • RJ11 Cable
  • Alligator Clip Cable
  • Screws, Screwdriver
  • RJ45 to BNC Connector (for models with VFL and OPM)
  • Type-C Charger Cable
  • User Manual
  • Tool Bag

4. Product Overview

4.1 Emitter Interfaces and Functions

Emitter Interfaces: Top view showing OPM port, LED, VFL port, Type-C charging port. Side view showing Pair/Con/Scan, Port flash/Length, PoE In, PoE Out ports.

Image: Emitter Interfaces: Top view showing OPM port, LED, VFL port, Type-C charging port. Side view showing Pair/Con/Scan, Port flash/Length, PoE In, PoE Out ports.

No.Description
1Port Indicators
2Power On/Off Button
3Left Direction Key
4Settings Key (Backlight, Auto Shutdown, Optical Power Calibration)
5REF Key (Optical Power Difference)
6Main Function Switch Key
7LED Light Key
8Right Direction Key
9Confirm Key
10HOLD Key (Optical Power Lock)
11Optical Power Meter Port (OPM) (Optional)
12LED Light
13Visual Fault Locator Port (VFL) (Optional)
14USB Type-C Charging Port
15UTP/Continuity Test/Cable Tracing Port
16Port Flashing/Length Test Port
17PoE Input Port
18PoE Output Port (Loopback output from PoE input, not powered by device)

4.2 Receiver Interfaces and Functions

Receiver Unit with Power Indicator, Earphone Jack, PD Powered Test Port, USB 5V Charging Port, Power Button, SNCV/Silent Key, 100M/1000M Indicator, UTP Cable Sequence/Signal Strength Indicator, Shielded Layer Continuity Indicator, Mode Indicator, Sensitivity Knob, Mode Button, LED Switch, UTP Cable Test Port.

Image: Receiver Unit with Power Indicator, Earphone Jack, PD Powered Test Port, USB 5V Charging Port, Power Button, SNCV/Silent Key, 100M/1000M Indicator, UTP Cable Sequence/Signal Strength Indicator, Shielded Layer Continuity Indicator, Mode Indicator, Sensitivity Knob, Mode Button, LED Switch, UTP Cable Test Port.

No.Description
1LED Light
2Power Indicator
3Earphone Jack
4PD Powered Test Port (Flashing: standard PoE; Constant: non-standard PoE)
5USB 5V Charging Port
6Power Button (Long press to turn on/off; Red light when charging, off when fully charged)
7SNCV/Silent Key (Long press for silent mode, short press for SNCV in SCAN+NCV mode)
8100M/1000M Indicator
9UTP Cable Sequence/Signal Strength Indicator
10Shielded Layer Continuity Indicator
11Mode Indicator
12Sensitivity Knob
13MODE Button (Short press to switch SCAN/NCV/UTP mode; Set automatic shutdown time)
14LED Switch
17UTP Cable Test Port

5. Initial Setup

5.1 Battery Connection

The tester has a built-in lithium-ion rechargeable battery. The battery cable inside the battery compartment is disconnected for safety during transportation. Before using the product, it is necessary to connect the battery cable.

Battery Connection: Image showing the unenergized state with disconnected battery cable and energized state with connected battery cable.

Image: Battery Connection: Image showing the unenergized state with disconnected battery cable and energized state with connected battery cable.

5.2 Power On/Off

Press and hold the power button for 2 seconds to turn the device on or off.

Attention: If the Emitter displays “Lo” and the battery icon is low, the battery needs to be charged. If the receiver's 1-8 signal indicators keep flashing or the power indicator light is red, the Receiver needs to be charged.

6. Operating Instructions

6.1 Setting Backlight Time and Auto Shutdown

Emitter Automatic Shutdown Setting

In the power-on state, press the Settings key (Settings key icon) to enable and switch between auto shutdown or backlight timeout options. Use the Left or Right keys to set the time.

  • Auto shutdown can be set from 0 to 240 minutes (0 means auto shutdown is off).
  • Backlight timeout can be set from 0 to 60 seconds (0 means the backlight stays on).

Press the Confirm key to save settings. Press the Menu key to exit without saving.

Automatic Shutdown Time Setting on Emitter

Image: Automatic Shutdown Time Setting on Emitter, showing PWR Min and BL settings.

Receiver Automatic Shutdown Setting

In the shutdown state, press and hold the receiver MODE button, then press the Power key to turn on and enter the shutdown time setting mode. The "straight, Cross, Other" and sequence indicator lights will flash.

Press the MODE key to modify the shutdown time. One line sequence indicator light represents 10 minutes. If the 1-3 indicator lights are on, it indicates that the current automatic shutdown time is set to 30 minutes. This can be set from 10-90 minutes. If all indicator lights are not on, automatic shutdown is turned off.

After setting up, press the Power key to save and exit the setting mode.

6.2 Cable Tracing

Connect the network or telephone cable to the "Wire Mapping/Continuity Test/Cable Tracing" port on the Emitter. Press the Menu key to switch to the cable tracing function (default on startup). The receiver can then be used for cable tracing.

Adjust the sensitivity knob on the receiver. When scanning the target cable, the closer the receiver's probe, the stronger the signal and the louder the sound.

Press and hold the "SNCV" key on the receiver to enter or exit silent mode.

Use the Left and Right keys to switch between UTP and STP modes. UTP is for unshielded network cables, and STP is for shielded network cables.

Digital Scanning for Cable Tracing

Image: Digital Scanning for Cable Tracing, showing various cable types (Network, Telephone, Coaxial, RVV Power, Elevator, Video Cable) and the receiver tracing a cable bundle.

Quickly verify the tracking result: After finding the cable, connect the network cable to the receiver's “UTP” port for pair line detection. When the "Straight/Cross/Other" indicator is on, it verifies the matching cable.

Note: The UTP port of the emitter and receiver can withstand a maximum of 60V. The wire can be traced directly in connection with a PoE switch.

6.3 NCV Mode (Non-Contact Voltage)

Turn on the receiver, press the “Mode” button. The "NCV" indicator will turn red, allowing simultaneous cable tracing and NCV scan.

When the probe detects nearby AC voltage, the “NCV” indicator will flash on the receiver and emit a beeping alarm. The 1-5 indicators on the panel will flash to indicate the current NCV scan signal strength. Different signal strengths will result in different beeping frequencies and light flashing frequencies.

Cable Scan + NCV (Live Wire Detection)

Image: Cable Scan + NCV (Live Wire Detection), illustrating detection of live wires and identification of neutral/live wires with visual and audible alerts.

When the receiver is in "SCAN + NCV" mode, press the "SNCV/Silent" key to increase scan sensitivity. This can be used to trace plastic water pipes or high-voltage wires inside walls (not effective for iron pipes).

Note: This function only works in "SCAN + NCV" mode. For safety, before working with wires, always verify that they are de-energized with an additional voltage tester.

Live/Neutral Wire Detection Mode

Touch the receiver's probe to the live/neutral wires in an electrical box or the live/neutral holes in wall sockets or power strips. The indicator lights and beeping alarm will help distinguish between live and neutral wires.

  • Live Wire: The indicator flashes quickly, and the beep is rapid.
  • Neutral Wire: The indicator does not light up or flashes slowly, with no beep or a slow beep.

6.4 UTP/Continuity Test

UTP Test

Connect the network or telephone cable to the "CONT/SCAN" port on the Emitter, and the other end to the UTP port on the receiver (the receiver must be powered on).

On the Emitter, press the Menu key to switch to the "CONT" (continuity) function mode to perform the wire mapping test.

The 1-8 and S sequence indicators on the screen will display the network cable sequence.

  • 1Gbps/100Mbps: Indicates whether the cable can be used for 1000M or 100M Ethernet networks. A straight-through connection will be displayed with a "|", and a crossed connection will be displayed with a jumping indicator. The receiver can also display this information.
  • 255: Receiver number, which can be customized.
Continuity Test - Gigabit Straight-Through Cable

Image: Continuity Test - Gigabit Straight-Through Cable, showing the display for a normal gigabit straight-through cable connection.

The receiver's network cable type indicator can quickly determine if the cable is normal. If it shows "Straight" or "Cross", the cable is normal. When testing the sequence, a "beep" indicates a connected pair, and a "buzz" indicates a short-circuit pair (all short-circuit pairs will light up simultaneously).

After the 8 indicators stop flashing, the receiver will beep to indicate the cable type: one "buzz" sound for straight-through, two "buzz" sounds for cross, and three "buzz" sounds for other or incorrect connections.

Quick Test Single Side Cable Crystal Connector Crimping Test

Image: Quick Test Single Side Cable Crystal Connector Crimping Test, showing normal and disconnected states for crystal head crimping.

Continuity Test (RJ45 Connector)

The continuity test checks the connection of the RJ45 connector or the cable within 10cm of the port (note: the receiver tests up to 1 meter).

In Continuity test mode, connect the network cable to the "CONT/SCAN" port on the Emitter. The "1-8, S" indicators will show the continuity test results. If the indicators light up, the RJ45 connector is properly crimped. If an indicator light is off, the corresponding pin of the RJ45 connector is abnormal.

Note: In Wire Pairing/Crimping or cable tracing function, if a wire pairing short circuit or abnormal detection occurs without physical connections, press the Settings key in the continuity test interface, then press the Power key to reset the continuity test function.

6.5 Length Measurement

Measure the length of open/short-circuited network cables from 1 to 600 meters. Ensure the other end of the cable is not connected to any device or powered on. Insert the cable into the "Length/Flash" port on the left side of the Emitter.

On the Emitter, press the Menu key to switch to the "Length" function mode, then press the Confirm key to start the length measurement.

Network Cable Length Measurement (Max 600M)

Image: Network Cable Length Measurement, showing the display indicating cable length up to 600M.

After the testing is completed, the results for each twisted pair will be displayed on the screen.

Switching Numerical Unit

Press the Settings key to switch the numerical unit. Use the Left or Right keys to switch between meters (m) and feet (Ft). The flashing unit indicates the current selection. Press the Confirm key to save the unit.

6.6 Port Flashing

Connect the network cable to the "Flash" port on the Emitter, and the other end to a switch or router.

On the Emitter, press the Menu key to switch to the "Flash" function mode. The device will automatically start the test.

The device will send a flashing signal. If the connection is normal, the switch port icon on the screen will flash at a certain frequency. If the connection is not normal (e.g., the cable is not properly connected), the switch port will not change. The switch or router port will flash at a fixed frequency, making it easy to identify the target port and avoid unplugging the wrong cable.

Port Flash - Finding Target Cable

Image: Port Flash - Finding Target Cable, showing network port indicators blinking regularly on a switch and the tester display.

Port Rate Detection

The port rate is automatically detected simultaneously when port flashing.

Possible reasons for abnormal results:

  1. The wrong port was connected to the Emitter.
  2. The network cable is faulty or not properly connected.
  3. The ports of the switch or router are faulty.
  4. The instrument is faulty.

6.7 PoE Detection

The PoE detection function is used to detect the PoE power supply protocol, line pairs, voltage, and real-time power when connected to a PD load device. It supports IEEE802.3bt/at/af and non-standard protocols.

Connect the network cable to the "PoE Input" port on the Emitter, and the other end to a PoE switch or power supply.

On the Emitter, press the Menu key to switch to the "PoE" function mode. The device will automatically start the test.

PoE++ (90W) PoE Test

Image: PoE++ (90W) PoE Test, illustrating PoE voltage detection, real-time power, and pair detection when connected to a PoE switch and a camera.

PD powered detection: The PD interface at the bottom of the receiver, when connected to the PoE switch or power supply, will show an indicator light if there is PoE voltage output. The 1236 and 4578 indicator lights indicate that the cable pair is powered. When both indicators are on, it indicates that both pairs are powered.

6.8 Optical Power Meter (Optional)

Connect the fiber optic cable to the "OPM" port on the Emitter, and the other end to an optical terminal or fiber optic transceiver.

Optical Power Meter (Wavelength Support)

Image: Optical Power Meter, showing support for various wavelengths and connection to an optical fiber device.

Function Key Description

  • HOLD: Lock display
  • REF: Difference measurement
  • Left/Right Keys: Wavelength choice
  • Confirm Key: Switch the unit

Operating Instructions

  1. When an optical signal is detected, the optical power detection value of the meter will change.
  2. Press the Left or Right keys to select the wavelength. If the measurement wavelength is not at the calibration wavelength point, select a similar calibration wavelength point.

Lock Display Function

When measuring, press HOLD. The display content will be locked and will not change. The HOLD button light will be on for easy reading. Press the HOLD button again to cancel the lock.

Difference Measurement Function (Optical Fiber Loss Measurement)

When measuring, press REF. The "REF" button lights up. The instrument automatically stores the current value and then displays the difference between the new measurement value and that value. Press the difference display button again to cancel the difference display and return to the real measurement display state.

User Self-Calibrated Optical Power Values

When measuring, first select the current laser wavelength, then hold down the Settings key for 2 seconds. The optical power value will flash, indicating entry into self-calibration mode. Use the Left or Right keys to select the new optical power value. Press the Confirm key to save changes and exit. Press the Menu key to exit without saving changes. In self-calibration mode, press and hold the Settings key again for 2 seconds to restore the factory calibrated optical power value and exit calibration mode.

6.9 Visual Fault Locator (Optional)

Connect the fiber optic cable to the "VFL" universal connector on the top of the device. On the Emitter, press the Menu key to switch to the "VFL" function mode.

By default, the red laser source outputs 10mW at a wavelength of 650nm.

Press the Left or Right keys to turn on/off and switch between stable and pulse modes (1Hz, 2Hz).

Visual Fault Locator (Wavelength 650nm)

Image: Visual Fault Locator, showing the VFL port and the red laser output for detecting fiber faults.

⚠️ Note: The emission laser source is a high-intensity laser light source. Do not look at the laser emission port with your eyes or aim at your eyes, which may cause eye damage.

7. Technical Specifications

Technical Specifications Table for LT-300S

Image: Detailed Technical Specifications Table for the LT-300S Network Cable Tester.

CategoryItemSpecification
ProductModelMulti-function Network Cable Tester LT-300S
Display3.0-inch HD display (48*65mm)
Cable Tracing/Wire Mapping/Continuity TestTransmit SignalDigital signal (rejects noise and false signals)
Cable TypesRJ45 twisted pair, RJ11 telephone cable, BNC video cable, low-voltage metal cables
UTP Cable TestTests 2+ wires in network cable. Displays connection sequence, Gigabit/100M, cable number. Receiver identifies via indicator lights.
Continuity TestEmitter: Min. recognition length 10cm
Receiver: Min. recognition length 1m
Short Circuit DetectionSupports network cable short circuit detection
Length MeasurementCable LengthMeasures open/short-circuited network cables from 1 to 600 meters. Accuracy: Cable length x 3% ± 1m
Port FlashingFunctionQuickly locates ports connected to Ethernet switches and other devices.
PoE TestingFunctionSupports IEEE802.3BT/AT/AF and non-standard protocol detection. Displays power supply voltage, pins, polarity. PoE input voltage loop-through output. Real-time power (0-90W).
PD Power DetectionDetects standard or non-standard PoE, supports 24V and 48V PoE.
Optical Power Meter (*optional)Wavelength (nm)850/980/1270/1300/1310/1490/1550/1577/1625/1650nm
Power Range (dBm)-70 to +6dBm
Visual Fault Locator (*optional)FunctionEmits visible red laser to detect fiber optic breaks, cracks, bends, and other faults.
Power SupplyEmitter Battery3.7V 2000mAh lithium-ion rechargeable battery
Receiver Battery3.7V 2000mAh lithium-ion rechargeable battery
GeneralWorking Temperature-10℃ to +50℃
Working Humidity30%-90%
Dimensions (Emitter/Receiver)Emitter: 142mm x 64mm x 30mm / 0.2Kg
Receiver: 218mm x 48mm x 32mm / 0.15Kg

The above data is for reference only. Specifications may change without prior notice.

8. User Tips

  • For accurate cable length measurements, ensure the cable is disconnected from all devices and power sources.
  • When using the cable tracing function, start with maximum sensitivity on the receiver and gradually decrease it to pinpoint the cable more precisely.
  • Always check battery levels before starting extensive testing to avoid interruptions.

9. Troubleshooting

9.1 General Issues

  • Device not powering on: Ensure the battery cable is properly connected inside the compartment. Charge the device if the battery indicator shows low power.
  • Inaccurate cable length measurement: Verify that the cable is completely disconnected from all network devices and power sources.
  • Port Flashing shows abnormal results: Check if the correct port is connected to the Emitter, inspect the network cable for faults or improper connections, and ensure the switch/router ports are functional.

9.2 Continuity Test Issues

  • RJ45 connector pin not crimped properly: If an indicator light is off during the continuity test, the corresponding pin is abnormal. Re-crimp the connector.
  • Wire pairing short circuit/abnormal detection without physical connections: Press the Settings key in the continuity test interface, then press the Power key to reset the continuity test function.

10. Support

For detailed technical inquiries or if you encounter any issues during use, please contact our technical support team. Do not attempt to disassemble or repair the device yourself, as this may void any applicable warranty.

A detailed user manual is also available in PDF format for download: User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?