1. Introduction
The HTI HT-H100 is a high-precision professional handheld infrared thermal imaging device designed for a wide range of applications. This thermal imager provides clear and sharp thermal images, making it an ideal tool for various inspection, maintenance, and detection tasks.
Its powerful functionality and multiple color palette options allow for effective visualization of temperature differences, suitable for diverse scenarios including:
- Inspection of electrical equipment and circuits
- Mechanical equipment maintenance
- Search for concealed fire-fighting supplies
- Search and rescue of accident victims
- Nighttime safety patrol
- Thermal pipeline and heating equipment inspection
- Medical care, fire protection, archaeology, transportation, agriculture, geology, smelting, and electronic manufacturing.

2. Product Overview
The HT-H100 features a compact, handheld design with an intuitive interface. Below is a diagram illustrating the key components and their functions.

Key Components:
- Center Point Temperature: Displays the temperature at the center of the screen.
- Emissivity: Adjustable parameter for accurate temperature measurement.
- Center Point Temperature Cursor: Visual indicator for the center temperature.
- 2.4-Inch LCD Display: For viewing thermal images and menu options.
- Minimum Temperature (MIN): Displays the lowest temperature detected in the current view.
- Maximum Temperature (MAX): Displays the highest temperature detected in the current view.
- Confirm/Menu Button: Used to confirm selections and access the main menu.
- Power Button: Turns the device on/off.
- Back Button: Navigates back in menus or cancels an action.
- Handheld Area: Ergonomic grip for comfortable use.
- TYPE-C Port (with Protective Cover): For charging and data export.
- Fill Light: Provides illumination for visible light images.
- Infrared Thermal Imaging Sensor: Captures thermal data.
- Image Capture Button: Takes a snapshot of the current thermal image.
- Battery Compartment: Houses the rechargeable lithium battery.
3. Specifications
The following table details the technical specifications of the HTI HT-H100 thermal imager:
| Feature | Specification |
|---|---|
| Model | HT H100 |
| Detector Type | Vox |
| Infrared Thermal Resolution | 96x96 ISR (240x240) |
| Field Angle | 50° (H) x 50° (V) |
| NETD | ≤60mK@25°C, F#1.0 |
| Measuring Range | -20°C ~ 550°C (-4°F ~ 1022°F) |
| Spectral Range | 8 ~ 14μm |
| Pixel Spacing | 12μm |
| Frame Rate | ≤25Hz |
| Focal Length | 1.35mm |
| Emissivity | 0.01 ~ 1.00 adjustable (default 0.95) |
| Measurement Accuracy | ±2°C or ±2% (maximum) |
| Temperature Measurement Resolution | 0.1°C |
| Menu Language | English, Chinese, Italian, German |
| Temperature Measurement Mode | Center point/max temperature/min temperature |
| Color Palette | Rainbow/Iron red/Red heat/White heat/Black heat |
| Display Screen | 2.4 inches (240x320) |
| Image Display Mode | Infrared |
| Device Storage | Built-in 128M FLASH (approx. 50M available for user) |
| File Format | JPG |
| Image/Video Export | USB connection computer export |
| Visible Light Resolution | 640x480 |
| Battery Type | Chargeable lithium battery (18650) |
| Battery Capacity | 1000mAh |
| Working Time | ≥3 hours |
| Operating Temperature | -5°C to +40°C |
| Storage Temperature | -10°C to +50°C |
| Relative Humidity | 10%-85%RH (non-condensing) |
| Product Size | 208mm x 60.9mm x 75.9mm |
| Product Weight | 233.8g |

4. Setup
4.1 Battery Installation and Charging
The HT-H100 comes with a built-in rechargeable 18650 lithium battery. Ensure the battery is sufficiently charged before first use.
- Locate the Battery Compartment on the device (refer to Figure 2).
- If the battery is not pre-installed, insert the 18650 lithium battery into the compartment, ensuring correct polarity.
- Close the battery compartment securely.
- To charge the device, open the protective cover of the TYPE-C port.
- Connect the device to a power source using a standard USB Type-C cable. The charging indicator (if present) will show the charging status.
- A full charge provides approximately 3 hours of working time.
4.2 Initial Power On
After ensuring the battery is charged, press and hold the Power Button until the 2.4-inch LCD Display illuminates. The device will perform a self-check and then display the thermal imaging interface.
5. Operating Instructions
5.1 Power On/Off
- To Power On: Press and hold the Power Button until the screen turns on.
- To Power Off: Press and hold the Power Button until the device shuts down.
5.2 Navigation and Menu
- Use the Confirm/Menu Button to enter the main menu or confirm a selection.
- Use the Back Button to return to the previous screen or cancel an action.
- Navigate through menu options using the directional buttons (often integrated with Confirm/Menu or Back buttons, or separate arrows if available).
5.3 Selecting Color Palettes
The HT-H100 offers five different color palettes to visualize thermal data, allowing you to choose the most appropriate display for your specific application and environment. These can be switched freely via the menu.
- Rainbow: Provides a full spectrum of colors, often good for general use.
- Iron Red: Highlights hotter areas in red/yellow and cooler areas in blue/purple.
- Red Heat: Emphasizes hot spots with shades of red.
- White Heat: Displays hotter objects as white and cooler objects as black.
- Black Heat: Displays hotter objects as black and cooler objects as white.

5.4 Adjusting Emissivity
Emissivity is a crucial parameter for accurate temperature measurement. It can be adjusted from 0.01 to 1.00. The default value is set at 0.95. Adjusting emissivity based on the material being inspected ensures more accurate readings.
Refer to the table below for common material emissivity values:
| Substance | Heat Radiation | Substance | Heat Radiation |
|---|---|---|---|
| Bitumen | 0.90-0.98 | Black Cloth | 0.98 |
| Concrete | 0.94 | Human Skin | 0.98 |
| Cement | 0.96 | Foam | 0.75-0.80 |
| Sand | 0.90 | Charcoal Powder | 0.96 |
| Soil | 0.92-0.96 | Lacquer | 0.80-0.95 |
| Water | 0.92-0.96 | Matte Paint | 0.97 |
| Ice | 0.96-0.98 | Black Rubber | 0.94 |
| Snow | 0.83 | Plastics | 0.85-0.95 |
| Glass | 0.90-0.95 | Wood | 0.90 |
| Ceramics | 0.90-0.94 | Paper | 0.70-0.94 |
| Marble | 0.94 | Chromium Oxide | 0.81 |
| Gypsum | 0.80-0.90 | Copper Oxide | 0.78 |
| Mortar | 0.89-0.91 | Iron Oxide | 0.78-0.82 |
| Brick | 0.93-0.96 | Textile | 0.90 |

5.5 Capturing Images and Data Export
- Image Capture: Press the Image Capture Button to save the current thermal image. Images are saved in JPG format to the internal 128M FLASH memory.
- Data Export: Connect the device to a computer using a USB Type-C cable. The device will appear as a removable storage device, allowing you to transfer saved JPG images.
6. Maintenance
Proper maintenance ensures the longevity and accuracy of your HTI HT-H100 thermal imager. Pay special attention to lens cleaning.
6.1 General Cleaning
- The outer shell of the product should be cleaned with a damp cloth or diluted soapy water.
- Do NOT use abrasives, isopropanol, or solvents for cleaning the outer shell.
6.2 Lens Maintenance
The infrared lens has a fine anti-reflection coating and requires careful handling. Use professional light for lenses and screens, or specialized lens cleaning agents.
- Carefully clean the infrared lens. Avoid applying force to prevent damaging the anti-reflective coating.
- For cleaning, use a commercial lens cleaning solution (containing alcohol) and a piece of lint-free cloth or tissue.
- Alternatively, compressed air tanks or dry nitrogen ion guns (if applicable) can be used to blow particles off the surface of the lens.
- To clean with a cloth:
- Soak the lint-free cloth in alcohol.
- Twist off excess liquid from the cloth or gently apply a lint-free cloth onto a dry cloth.
- Perform circular motion on the surface of the lens for wiping, and then discard the cloth strip.
- To repeat the above steps, use a new cloth strip dipped in liquid to wipe.

7. Troubleshooting
This section provides solutions to common issues you might encounter with your HTI HT-H100 thermal imager.
- Device does not power on:
- Ensure the battery is fully charged. Connect the device to a charger and wait for a few minutes before attempting to power on again.
- Check if the battery is correctly installed in its compartment.
- Image is blurry or unclear:
- Clean the infrared lens according to the maintenance instructions (Section 6.2). Dust or smudges on the lens can significantly affect image quality.
- Ensure the device is within its specified operating temperature range (-5°C to +40°C).
- Inaccurate temperature readings:
- Verify that the emissivity setting is correct for the material being measured (refer to Section 5.4).
- Ensure there are no obstructions between the thermal imager and the target object.
- Check if the device is operating within its specified temperature measurement accuracy range.
- Device freezes or becomes unresponsive:
- Try restarting the device by holding down the Power Button.
- If the issue persists, allow the battery to fully discharge and then recharge it before attempting to use the device again.
- Cannot export images to computer:
- Ensure the USB Type-C cable is securely connected to both the device and the computer.
- Check if the computer recognizes the device as a removable storage drive. Try a different USB port or cable if necessary.
If you encounter problems not listed here or if the suggested solutions do not resolve the issue, please refer to the support information in Section 8.
8. Warranty and Support
We strive to provide high-quality products and excellent customer service. If you encounter any quality issues with the product or experience problems during use, please contact the seller directly before initiating any disputes or leaving negative feedback. We will do our best to resolve your concerns and assist you.
For further assistance or to access the official user manual in PDF format, please refer to the following resource: