1. Introduction
1.1 Product Overview
The JIKONG Smart Active Balancer Battery Management System (BMS) is a sophisticated management system designed for large capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote capabilities. This BMS is compatible with various battery chemistries, including lithium iron phosphate (LiFePO4), ternary lithium, and lithium titanate (LTO) battery types.
The protection board utilizes energy transfer active balancing technology, capable of achieving a continuous 2A balance current. This high-current active equalization maximizes battery consistency, extends battery range, and delays battery aging. It is compact, easy to operate, and suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

1.2 Functional Characteristics
The JIKONG JK-B2A8S30P BMS offers a comprehensive set of features to ensure optimal battery performance and safety:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support ACC detection function (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support heating function (Optional)
- Support GPS communication
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection


2. Components and Interfaces
2.1 Packing List
Upon receiving your JIKONG JK-B2A8S30P BMS, please verify that all components are included in the package:
- BMS unit (1)
- NTC temperature sensor (1, 400mm)
- Balance Wires (1 set, 750mm)
- Switch (1, 500mm)
- Pack box (1)
- M6 screws (6)
- GH1.25mm-4P to SM A connector-2.54-2P+2P-150mm+100mm-CAN-485 cable (1)

2.2 Product Appearance and Dimensions
The JK-B2A8S-30P series protection board has dimensions of 182.75mm × 127.26mm × 15.6mm. The casing is made of aluminum alloy, utilizing one-piece molding technology for superior heat dissipation with a high thermal conductivity of <300[W/(m·K)]. The surface is sprayed with a layer of graphite material for uniform and balanced heat transfer.


2.3 Interface Definitions
The BMS features various interfaces for communication, balancing, and control. Refer to the diagram and table below for detailed pin definitions.

P1: XH-10AW-2.54 (Balance with Acquisition interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | B- | Total negative battery |
| 2 | B1 | The first battery positives |
| ... | ... | ... (up to B8 for 8S configurations) |
| 10 | B+ | Protection board power supply, connected to the battery |
P2: A1254WF-2A (Alarm interface - Optional)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | GND | Alarm power negative |
| 2 | VCC | Alarm power supply positive |
P3: A1254WF-4A (Communication interface - Optional)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | CAN L | CAN signal negative terminal |
| 2 | CAN H | CAN signal positive terminal |
| 3 | RS485 A | RS485 signal positive terminal |
| 4 | RS485 B | RS485 signal negative terminal |
P4: 1.25T-4PWT (GPS interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | GND | Power/signal ground |
| 2 | RX | UART RX, 3.3V |
| 3 | TX | UART TX, 3.3V |
| 4 | VGPS | Power output, voltage close to B+ |
P5: HY2.0-4P (Temperature interface - 4 external optional)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | T5A | Fifth temperature sensor pin A |
| 2 | T5B | Fifth temperature sensor pin B |
| ... | ... | ... (up to T1A/T1B for first sensor) |
P7: A1254WF-5A (ACC interface - Optional)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | ACC+ | ACC Positive |
| 2 | ACC- | ACC Negative |
| 3 | NC | Not Connected (Empty) |
| 4 | C_Detect+ | Charger output 12V positive |
| 5 | C_Detect- | Charger output 12V negative |
P8: A1254WF-6A (Display interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | VCC | Display power output |
| 2 | A | Display RS485 signal positive |
| 3 | B | Display RS485 signal negative |
| 4 | GND | Negative terminal |
| 5 | K+ | Activation signal positive |
P9: A1254WF-3A (Parallel interface - Optional)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | P-status | Parallel module status signal |
| 2 | P-EN | Parallel module enable signal, output low level to turn on parallel module |
| 3 | GND | Signal ground |
Heating Wire (16AWG - Orange Yellow - 15CM - Optional)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | HT- | Heater element negative electrode |
D1: Bluetooth connection indicator
- Steady on: Bluetooth is connected to the protection board.
- Blinking: Bluetooth is disconnected.
P-: Connect to external load or negative terminal of charger, equipped with M6 screws.
B-: Connect to the negative battery terminal, equipped with M6 screws.


3. Setup and Activation
3.1 Installation Method
The JK-B2A8S-30P series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always ensure correct polarity and secure connections.

Wiring Steps:
- Connect the balance wires (P1) to the battery cells, ensuring correct order from B- to B1, B2, up to B8, and finally B+.
- Connect the main negative terminal (B-) of the BMS to the battery pack's negative terminal.
- Connect the main positive terminal (P-) of the BMS to the load and charger negative terminals.
- If using the heating function, connect the heating wire (HT-) to the designated terminal and ensure a temperature control switch is in series for secondary protection.
- Connect optional interfaces such as GPS (P4), display (P8), CAN/RS485 (P3), parallel (P9), and ACC (P7) as required.
- Ensure all connections are secure and properly insulated.
3.2 Device Activation
Before powering on the protection board, double-check that the balance cables are properly connected and that P- and B- are correctly wired. Ensure the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a physical power-on switch. It is designed for charging activation. After the battery assembly is complete, connect a charger (with a voltage 2V higher than the battery voltage) to activate the BMS.
Alternatively, if you have an optional display screen or button, you can activate the BMS by connecting the cable to the display interface and pressing the button.
4. Operation and Functions
4.1 APP Operation Instructions
The JIKONG BMS features a mobile APP compatible with Android and iOS operating systems. The APP allows you to monitor battery status, modify working parameters, and control charge/discharge switches via Bluetooth.



4.2 Active Equalization
The BMS employs active equalization to transfer energy from higher-voltage cells to lower-voltage cells, minimizing energy loss. Before using this function, set basic battery parameters in the APP, including cell count, battery capacity, trigger equalization differential pressure (default value can be retained), voltage calibration, and current calibration. The default balance current is 2A, adjustable based on battery capacity (recommended not to exceed 0.2C). If not needed, the balancing switch can be turned off in the APP.

4.3 GPS and Display Interface
The BMS reserves a GPS port for optional GPS devices, meeting location tracking needs. A display interface is also available for connecting JIKONG displays, allowing users to view battery information directly.
4.4 Heating Function (Optional)
The optional heating function uses a resistance heater or heating film to warm the battery at low temperatures, preventing reduced activity and charging/discharging issues. The designed heating current is 20A. Users can control this function via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary safety measure.4.5 Alarm Function (Optional)
The optional alarm function provides external alerts when the BMS detects safety risks such as over-temperature, overcharge, or over-discharge.4.6 Battery Parallel Function (Optional)
This function supports parallel connection of battery packs for energy storage applications. It requires synchronous use with parallel modules and disabling the “charging current limiting” function in the APP.4.7 ACC Detection Function (Optional)
The optional ACC detection function enables discharge. It can be activated by applying 20V-100V between ACC+ and ACC- or by directly short-circuiting them. Charger detection interfaces (C_detect+ and C_detect-) are also provided for enabling charging.4.8 Protection Functions
The BMS includes various protection mechanisms to safeguard the battery:
- Charge Overvoltage Protection: Automatically turns off charging if any cell voltage exceeds the set overcharge protection voltage. Resumes charging when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection: Turns off discharge if any cell voltage falls below the set undervoltage protection voltage. Resumes discharge when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
- Charge/Discharge Overcurrent Protection: Triggers protection if the charging or discharging current exceeds the set continuous current for a specified delay. Resumes operation after a recovery time. (Note: Maximum continuous discharge current should not exceed 300A).
- Over-temperature Protection: Turns off charging/discharging if the temperature exceeds the set over-temperature protection value. Resumes when the temperature drops below the recovery value.
- Low Temperature Protection: Turns off charging if the temperature falls below the set low temperature protection value. Resumes when the temperature rises above the recovery value.
- Short Circuit Protection: Triggers protection if a short circuit is detected. Delay and recovery times can be configured. If a charging short circuit occurs, increasing the delay may resolve issues caused by charger peak current. For discharge short circuits, ensure external wiring is correct and consider increasing delay for loads with large internal capacitance.
4.9 Emergency Switch
The emergency switch function provides a 30-minute window for continued charge/discharge operation in case of over-temperature, over-discharge, over-charge, or cell drop issues. This allows users to safely manage the situation and prevent immediate shutdown, especially in critical scenarios.4.10 Intelligent Sleep
The intelligent sleep function (standard) allows users to enable or disable the BMS from entering a low-power standby state (charging/discharging current less than 1A for 26 consecutive hours) to reduce self-consumption. The BMS can be reactivated via a button or by connecting a charger.4.11 Communication Function
The BMS supports optional CAN and RS485 communication functions. Users can configure the address and communication protocol via the APP based on their specific requirements and scenarios. Refer to the JIKONG Protection Board communication protocol document for details.

5. Specifications
5.1 Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage | 7.5-36 | V |
| Operating power consumption | <1400 | mW |
| Operating temperature | -30-70 | °C |
| Max number of collection strings | 8 | String |
| Maximum balancing current | 2 | A |
| Maximum charging current | 300 | A |
| Maximum discharge current | 300 | A |
| Maximum instantaneous current | 600 | A |
| Maximum internal loop resistance | 0.25 | mΩ |
| Protective plate size | 182.75*127.26*15.6 | mm |
| Finished weight | 541 | g |
5.2 Default Parameters
The following table outlines the default parameter settings for different battery types. These can be adjusted via the APP.
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 2 | 2 | 2 | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 30 | 30 | 30 | S |
| Charging overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | uS |
| Short circuit protection release time | 30 | 30 | 30 | S |
| Charging overtemperature protection temperature | 70 | 70 | 70 | °C |
| Charging overtemperature restore temperature | 60 | 60 | 60 | °C |
| Discharge overtemperature protection temperature | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery temperature | 60 | 60 | 60 | °C |
| Charging low temperature protection temperature | -20 | -20 | -20 | °C |
| Charging low temperature to restore temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature protection temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery temperature | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |
6. Troubleshooting
This section provides general guidance for common issues. For detailed troubleshooting, refer to the APP's diagnostic features and the full PDF manual.
- BMS Not Activating: Ensure the charger voltage is at least 2V higher than the battery voltage. Check all balance wire and main power connections (P- and B-) for correctness and security.
- Balancing Issues: Verify that active equalization is enabled in the APP and that battery parameters (cell count, capacity) are correctly set. Check the trigger equalization differential pressure.
- Protection Triggered Frequently: Review the default parameters in the APP. Adjust overcurrent, overvoltage, or temperature protection thresholds if they are too sensitive for your application, ensuring they remain within safe limits. For short-circuit protection, consider increasing the delay time if false triggers occur with certain loads or chargers.
- Communication Problems (Bluetooth/CAN/RS485): Ensure Bluetooth is enabled on your mobile device and the BMS. For CAN/RS485, check cable connections (P3) and verify the communication protocol and address settings in the APP.
- Heating Function Not Working: Confirm the heating function is enabled in the APP. Check the heating wire connection and the external temperature control switch if installed.
7. User Tips
- Inverter Communication: If you intend to communicate with an inverter, such as a PowMr 4500, ensure the inverter supports CAN or RS485 protocols. An optional P-LINK-CR+RJ45 cable is available for this purpose.
- LCD Display: For direct visual monitoring of battery data, consider purchasing a product model that includes an LCD display. Various sizes (2.3, 3.2, 4.3 inch) are available.
- Cold Weather Operation: In extremely cold environments, utilize the optional heating function to maintain battery activity and prevent performance degradation.
8. Frequently Asked Questions
- Q: Can the BMS communicate directly with the PowMr 4500 inverter?
- A: The JIKONG BMS supports CAN and RS485 communication protocols. For direct communication with specific inverters like PowMr 4500, you must ensure that the inverter is compatible with these protocols. An optional P-LINK-CR+RJ45 cable is available to facilitate inverter communication.
- Q: Is this product original?
- A: Yes, this product is manufactured by JIKONG, a company specializing in active balance power battery management systems, ensuring authenticity and quality.
9. Support and Further Information
For more detailed information, including comprehensive parameter settings and advanced configurations, please refer to the full user manual PDF. You can access the PDF document here: JIKONG JK-B2A8S-30P User Manual (PDF).
For technical support or customized features, please contact JIKONG customer service.