1.1 Product Overview

The JIKONG Smart Active Balancer Battery Management System (BMS) is a sophisticated management system designed for large capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote capabilities. This BMS is compatible with various battery chemistries, including lithium iron phosphate (LiFePO4), ternary lithium, and lithium titanate (LTO) battery types.

The protection board utilizes energy transfer active balancing technology, capable of achieving a continuous 2A balance current. This high-current active equalization maximizes battery consistency, extends battery range, and delays battery aging. It is compact, easy to operate, and suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

JIKONG JK-B2A8S30P BMS with key features listed
Figure 1: JIKONG JK-B2A8S30P BMS highlighting V19 version, Li-ion/LiFePO4/LTO support, Heat/CANBUS/RS485, 2A Active Balance, 4S-8S 300A, and LCD options.

1.2 Functional Characteristics

The JIKONG JK-B2A8S30P BMS offers a comprehensive set of features to ensure optimal battery performance and safety:

  • LED Bluetooth status indicator
  • APP Bluetooth remote operation
  • Battery capacity calculation
  • High precision voltage acquisition (±3mV)
  • High precision current acquisition
  • Support information screen display
  • Accurate time logging
  • Support RS485 (Optional)
  • Support CAN (Optional)
  • Support ACC detection function (Optional)
  • Support parallel function (Optional)
  • Support alarm function (Optional)
  • Support heating function (Optional)
  • Support GPS communication
  • Charge overcurrent protection
  • Charge overvoltage protection
  • Charge over temperature protection
  • Low temperature protection during charge
  • Discharge overcurrent protection
  • Discharge undervoltage protection
  • Discharge over temperature protection
  • Short circuit protection
Diagram showing functional characteristics of the JIKONG BMS
Figure 2: Detailed list of functional characteristics and protections.
Various application scenarios for the JIKONG BMS
Figure 3: Wide range of application scenarios for the JIKONG BMS, including E-bikes, forklifts, drones, and RV energy storage.

2. Components and Interfaces

2.1 Packing List

Upon receiving your JIKONG JK-B2A8S30P BMS, please verify that all components are included in the package:

  • BMS unit (1)
  • NTC temperature sensor (1, 400mm)
  • Balance Wires (1 set, 750mm)
  • Switch (1, 500mm)
  • Pack box (1)
  • M6 screws (6)
  • GH1.25mm-4P to SM A connector-2.54-2P+2P-150mm+100mm-CAN-485 cable (1)
Diagram showing all items included in the JIKONG BMS packing list
Figure 4: Contents of the JIKONG BMS package.

2.2 Product Appearance and Dimensions

The JK-B2A8S-30P series protection board has dimensions of 182.75mm × 127.26mm × 15.6mm. The casing is made of aluminum alloy, utilizing one-piece molding technology for superior heat dissipation with a high thermal conductivity of <300[W/(m·K)]. The surface is sprayed with a layer of graphite material for uniform and balanced heat transfer.

Diagram showing the dimensions of the JIKONG JK-B2A8S-30P BMS
Figure 5: Dimensions of the JK-B2A8S-30P BMS unit.
Exploded view of the JIKONG BMS showing aluminum alloy shell and internal components
Figure 6: Exploded view illustrating the aluminum alloy shell and internal structure for heat dissipation.

2.3 Interface Definitions

The BMS features various interfaces for communication, balancing, and control. Refer to the diagram and table below for detailed pin definitions.

Diagram of JIKONG JK-B2A8S-30P BMS with labeled interfaces P1 through P9
Figure 7: Schematic diagram of the JK-B2A8S-30P connector interfaces.

P1: XH-10AW-2.54 (Balance with Acquisition interface)

Pin NumberNameDefinition
1B-Total negative battery
2B1The first battery positives
......... (up to B8 for 8S configurations)
10B+Protection board power supply, connected to the battery

P2: A1254WF-2A (Alarm interface - Optional)

Pin NumberNameDefinition
1GNDAlarm power negative
2VCCAlarm power supply positive

P3: A1254WF-4A (Communication interface - Optional)

Pin NumberNameDefinition
1CAN LCAN signal negative terminal
2CAN HCAN signal positive terminal
3RS485 ARS485 signal positive terminal
4RS485 BRS485 signal negative terminal

P4: 1.25T-4PWT (GPS interface)

Pin NumberNameDefinition
1GNDPower/signal ground
2RXUART RX, 3.3V
3TXUART TX, 3.3V
4VGPSPower output, voltage close to B+

P5: HY2.0-4P (Temperature interface - 4 external optional)

Pin NumberNameDefinition
1T5AFifth temperature sensor pin A
2T5BFifth temperature sensor pin B
......... (up to T1A/T1B for first sensor)

P7: A1254WF-5A (ACC interface - Optional)

Pin NumberNameDefinition
1ACC+ACC Positive
2ACC-ACC Negative
3NCNot Connected (Empty)
4C_Detect+Charger output 12V positive
5C_Detect-Charger output 12V negative

P8: A1254WF-6A (Display interface)

Pin NumberNameDefinition
1VCCDisplay power output
2ADisplay RS485 signal positive
3BDisplay RS485 signal negative
4GNDNegative terminal
5K+Activation signal positive

P9: A1254WF-3A (Parallel interface - Optional)

Pin NumberNameDefinition
1P-statusParallel module status signal
2P-ENParallel module enable signal, output low level to turn on parallel module
3GNDSignal ground

Heating Wire (16AWG - Orange Yellow - 15CM - Optional)

Pin NumberNameDefinition
1HT-Heater element negative electrode

D1: Bluetooth connection indicator

  • Steady on: Bluetooth is connected to the protection board.
  • Blinking: Bluetooth is disconnected.

P-: Connect to external load or negative terminal of charger, equipped with M6 screws.

B-: Connect to the negative battery terminal, equipped with M6 screws.

Protective Board 2P-CAN/485 Cable specification and wiring diagram
Figure 8: Specification and wiring diagram for the optional 2P-CAN/485 communication cable.
LCD display options with dimensions and cable lengths
Figure 9: Available LCD display options (2.3 inch, 3.2 inch, 4.3 inch) with their respective dimensions and cable lengths.

3. Setup and Activation

3.1 Installation Method

The JK-B2A8S-30P series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always ensure correct polarity and secure connections.

Wiring diagram for JIKONG JK-B2A8S-30P BMS
Figure 10: General wiring diagram for the JK-B2A8S-30P BMS, showing connections for load, charger, heating wire, temperature probe, and balance wires.

Wiring Steps:

  1. Connect the balance wires (P1) to the battery cells, ensuring correct order from B- to B1, B2, up to B8, and finally B+.
  2. Connect the main negative terminal (B-) of the BMS to the battery pack's negative terminal.
  3. Connect the main positive terminal (P-) of the BMS to the load and charger negative terminals.
  4. If using the heating function, connect the heating wire (HT-) to the designated terminal and ensure a temperature control switch is in series for secondary protection.
  5. Connect optional interfaces such as GPS (P4), display (P8), CAN/RS485 (P3), parallel (P9), and ACC (P7) as required.
  6. Ensure all connections are secure and properly insulated.

3.2 Device Activation

Before powering on the protection board, double-check that the balance cables are properly connected and that P- and B- are correctly wired. Ensure the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.

The protection board does not have a physical power-on switch. It is designed for charging activation. After the battery assembly is complete, connect a charger (with a voltage 2V higher than the battery voltage) to activate the BMS.

Alternatively, if you have an optional display screen or button, you can activate the BMS by connecting the cable to the display interface and pressing the button.

4. Operation and Functions

4.1 APP Operation Instructions

The JIKONG BMS features a mobile APP compatible with Android and iOS operating systems. The APP allows you to monitor battery status, modify working parameters, and control charge/discharge switches via Bluetooth.

QR code for JIKONG BMS mobile APP download
Figure 11: Scan this QR code to download the JIKONG BMS mobile APP. Android Version 7 or higher is required.
Screenshots of JIKONG BMS APP interface showing various settings and controls
Figure 12: JIKONG BMS APP interface for monitoring and control, including modifying PVD, charge/discharge ON/OFF, balance ON/OFF, and emergency ON/OFF.
Multi-screen display options for JIKONG BMS data
Figure 13: Data can be viewed via mobile APP, PC software, or optional JIKONG 4.3LCD display.

4.2 Active Equalization

The BMS employs active equalization to transfer energy from higher-voltage cells to lower-voltage cells, minimizing energy loss. Before using this function, set basic battery parameters in the APP, including cell count, battery capacity, trigger equalization differential pressure (default value can be retained), voltage calibration, and current calibration. The default balance current is 2A, adjustable based on battery capacity (recommended not to exceed 0.2C). If not needed, the balancing switch can be turned off in the APP.

Diagram explaining active balancing process in battery cells
Figure 14: Active Balancing (Lossless Balancing) mechanism, showing energy transfer between cells to achieve voltage balance.

4.3 GPS and Display Interface

The BMS reserves a GPS port for optional GPS devices, meeting location tracking needs. A display interface is also available for connecting JIKONG displays, allowing users to view battery information directly.

4.4 Heating Function (Optional)

The optional heating function uses a resistance heater or heating film to warm the battery at low temperatures, preventing reduced activity and charging/discharging issues. The designed heating current is 20A. Users can control this function via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary safety measure.4.5 Alarm Function (Optional)

The optional alarm function provides external alerts when the BMS detects safety risks such as over-temperature, overcharge, or over-discharge.4.6 Battery Parallel Function (Optional)

This function supports parallel connection of battery packs for energy storage applications. It requires synchronous use with parallel modules and disabling the “charging current limiting” function in the APP.4.7 ACC Detection Function (Optional)

The optional ACC detection function enables discharge. It can be activated by applying 20V-100V between ACC+ and ACC- or by directly short-circuiting them. Charger detection interfaces (C_detect+ and C_detect-) are also provided for enabling charging.4.8 Protection Functions

The BMS includes various protection mechanisms to safeguard the battery:

  • Charge Overvoltage Protection: Automatically turns off charging if any cell voltage exceeds the set overcharge protection voltage. Resumes charging when all cell voltages drop below the recovery voltage.
  • Discharge Undervoltage Protection: Turns off discharge if any cell voltage falls below the set undervoltage protection voltage. Resumes discharge when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
  • Charge/Discharge Overcurrent Protection: Triggers protection if the charging or discharging current exceeds the set continuous current for a specified delay. Resumes operation after a recovery time. (Note: Maximum continuous discharge current should not exceed 300A).
  • Over-temperature Protection: Turns off charging/discharging if the temperature exceeds the set over-temperature protection value. Resumes when the temperature drops below the recovery value.
  • Low Temperature Protection: Turns off charging if the temperature falls below the set low temperature protection value. Resumes when the temperature rises above the recovery value.
  • Short Circuit Protection: Triggers protection if a short circuit is detected. Delay and recovery times can be configured. If a charging short circuit occurs, increasing the delay may resolve issues caused by charger peak current. For discharge short circuits, ensure external wiring is correct and consider increasing delay for loads with large internal capacitance.

4.9 Emergency Switch

The emergency switch function provides a 30-minute window for continued charge/discharge operation in case of over-temperature, over-discharge, over-charge, or cell drop issues. This allows users to safely manage the situation and prevent immediate shutdown, especially in critical scenarios.4.10 Intelligent Sleep

The intelligent sleep function (standard) allows users to enable or disable the BMS from entering a low-power standby state (charging/discharging current less than 1A for 26 consecutive hours) to reduce self-consumption. The BMS can be reactivated via a button or by connecting a charger.4.11 Communication Function

The BMS supports optional CAN and RS485 communication functions. Users can configure the address and communication protocol via the APP based on their specific requirements and scenarios. Refer to the JIKONG Protection Board communication protocol document for details.

Icons representing various communication and control interfaces
Figure 15: Rich interface options including CAN, RS485, Bluetooth, NTC, Soft Switch, SOC Indicator, Key Switch, and Active Equalizer.

5. Specifications

5.1 Basic Parameters

ParameterValueUnit
Supply voltage7.5-36V
Operating power consumption<1400mW
Operating temperature-30-70°C
Max number of collection strings8String
Maximum balancing current2A
Maximum charging current300A
Maximum discharge current300A
Maximum instantaneous current600A
Maximum internal loop resistance0.25mΩ
Protective plate size182.75*127.26*15.6mm
Finished weight541g

5.2 Default Parameters

The following table outlines the default parameter settings for different battery types. These can be adjusted via the APP.

ParameterLi-ion (Default)LiFePO4 (Default)LTO (Default)Unit
Balancing initial voltage332V
Maximum balancing current222A
Unit overcharge voltage4.23.62.7V
Overcharge protection recovery4.183.552.65V
Monomer undervoltage protection2.822.61.8V
Undervoltage protection recovery2.852.651.85V
Automatic shutdown voltage2.82.51.7V
SOC-0% voltage2.92.61.85V
SOC-100% voltage4.183.52.65V
Trigger balancing differential pressure0.010.010.01V
Charging overcurrent protection delay303030S
Charging overcurrent protection release time606060S
Discharge overcurrent protection delay300300300S
Discharge overcurrent protection release time606060S
Short-circuit protection delay555uS
Short circuit protection release time303030S
Charging overtemperature protection temperature707070°C
Charging overtemperature restore temperature606060°C
Discharge overtemperature protection temperature707070°C
Discharge overtemperature recovery temperature606060°C
Charging low temperature protection temperature-20-20-20°C
Charging low temperature to restore temperature-10-10-10°C
MOS Overtemperature protection temperature100100100°C
MOS Overtemperature protection recovery temperature808080°C
Device address000/

6. Troubleshooting

This section provides general guidance for common issues. For detailed troubleshooting, refer to the APP's diagnostic features and the full PDF manual.

  • BMS Not Activating: Ensure the charger voltage is at least 2V higher than the battery voltage. Check all balance wire and main power connections (P- and B-) for correctness and security.
  • Balancing Issues: Verify that active equalization is enabled in the APP and that battery parameters (cell count, capacity) are correctly set. Check the trigger equalization differential pressure.
  • Protection Triggered Frequently: Review the default parameters in the APP. Adjust overcurrent, overvoltage, or temperature protection thresholds if they are too sensitive for your application, ensuring they remain within safe limits. For short-circuit protection, consider increasing the delay time if false triggers occur with certain loads or chargers.
  • Communication Problems (Bluetooth/CAN/RS485): Ensure Bluetooth is enabled on your mobile device and the BMS. For CAN/RS485, check cable connections (P3) and verify the communication protocol and address settings in the APP.
  • Heating Function Not Working: Confirm the heating function is enabled in the APP. Check the heating wire connection and the external temperature control switch if installed.

7. User Tips

  • Inverter Communication: If you intend to communicate with an inverter, such as a PowMr 4500, ensure the inverter supports CAN or RS485 protocols. An optional P-LINK-CR+RJ45 cable is available for this purpose.
  • LCD Display: For direct visual monitoring of battery data, consider purchasing a product model that includes an LCD display. Various sizes (2.3, 3.2, 4.3 inch) are available.
  • Cold Weather Operation: In extremely cold environments, utilize the optional heating function to maintain battery activity and prevent performance degradation.

8. Frequently Asked Questions

Q: Can the BMS communicate directly with the PowMr 4500 inverter?
A: The JIKONG BMS supports CAN and RS485 communication protocols. For direct communication with specific inverters like PowMr 4500, you must ensure that the inverter is compatible with these protocols. An optional P-LINK-CR+RJ45 cable is available to facilitate inverter communication.
Q: Is this product original?
A: Yes, this product is manufactured by JIKONG, a company specializing in active balance power battery management systems, ensuring authenticity and quality.

9. Support and Further Information

For more detailed information, including comprehensive parameter settings and advanced configurations, please refer to the full user manual PDF. You can access the PDF document here: JIKONG JK-B2A8S-30P User Manual (PDF).

For technical support or customized features, please contact JIKONG customer service.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.