1. Introduction

The Marposs Q4124015000 is a high-precision Tool Eye Q Setter Head, part of the advanced A90K series tool-setting touch probes. This robust industrial device is engineered for critical applications in CNC lathes and machining centers, providing accurate tool length presetting and reliable tool integrity checks. Its compact design and high repeatability make it an essential component for maintaining precision in manufacturing processes. The probe is commonly integrated into Doosan OEM machines and features a standard 6-pin interface for connectivity.

Marposs Q4124015000 Tool Eye Q Setter Head
Figure 1: Marposs Q4124015000 Tool Eye Q Setter Head, a precision tool for CNC machines.

2. Specifications

Attribute Detail
Product Name Probe
Model Number Q4124015000
Brand Name Marposs
Origin Germany
Application Industrial (CNC Lathes, Machining Centers)
Condition 100% new original
Package Original Package
Rated Current / (Not specified)
Rated Voltage / (Not specified)
Feature High Efficiency
Material Other (Precision Metals)
Connectivity 6-pin interface
Weight Approximately 0.4 kg
Detailed view of Marposs Q4124015000 probe
Figure 2: Detailed view of the Marposs Q4124015000 probe, highlighting its compact build and precision components.

3. Setup and Installation

The Marposs Q4124015000 Tool Eye Q Setter Head is a precision instrument designed for integration into CNC machinery. Proper installation is crucial for optimal performance and accuracy. It is highly recommended that installation and initial setup be performed by qualified personnel with experience in CNC machine tool integration and industrial probe systems.

3.1 Pre-Installation Checks

  • Ensure the CNC machine is powered off and locked out according to safety procedures.
  • Verify that the mounting location on the CNC machine is clean, stable, and free from debris.
  • Confirm compatibility with your CNC control system and existing wiring.
  • Inspect the probe for any visible damage from shipping.

3.2 Mounting the Probe

  1. Carefully position the Q4124015000 probe in its designated mounting location within the CNC machine.
  2. Secure the probe using appropriate fasteners, ensuring it is firmly seated and aligned correctly. Refer to your CNC machine's specific mounting instructions for precise details.

3.3 Electrical Connection

  • Connect the probe to the CNC control system using its 6-pin interface cable.
  • Ensure all connections are secure and correctly polarized to prevent damage.
  • Consult the CNC machine's electrical diagrams and the probe's technical documentation for exact wiring specifications.
Side view of Marposs Q4124015000 probe showing connection interface
Figure 3: Side view of the Q4124015000 probe, illustrating its robust construction and potential connection point.

3.4 Initial Calibration

After physical installation and electrical connection, the probe must be calibrated within the CNC machine's control software. This process typically involves:

  • Defining the probe's offset values.
  • Performing touch tests to verify repeatability and accuracy.
  • Adjusting parameters as necessary to meet desired precision levels.

Refer to your CNC machine's programming manual and Marposs documentation for detailed calibration procedures.

4. Operation

The Marposs Q4124015000 Tool Eye Q Setter Head is designed to automate and enhance the precision of tool management in CNC operations. Its primary functions include tool length presetting and tool integrity checks.

4.1 Tool Length Presetting

This function allows the CNC machine to automatically measure the exact length of a tool. This data is then used by the CNC control to compensate for tool wear or changes, ensuring consistent machining depth and accuracy.

  1. Load the tool into the spindle.
  2. Execute the tool presetting cycle from the CNC control panel.
  3. The spindle will move the tool towards the probe, making contact.
  4. The probe sends a signal to the CNC control upon contact, recording the tool's length.
  5. The CNC system updates the tool offset table with the new length.

4.2 Tool Integrity Checks

The probe can also be used to detect broken or chipped tools, preventing costly machining errors and potential damage to workpieces or the machine itself.

  1. After a machining operation or at programmed intervals, execute a tool integrity check cycle.
  2. The tool will approach the probe at a predefined position.
  3. If the tool makes contact within expected parameters, it is deemed intact.
  4. If no contact is made (indicating a broken tool) or contact is made outside the tolerance (indicating a chipped tool), the CNC system will trigger an alarm or stop the operation.
Marposs Q4124015000 probe with stylus extended, ready for measurement
Figure 4: The Q4124015000 probe with its stylus extended, indicating readiness for tool measurement or integrity checks.

Always refer to your CNC machine's specific programming manual for detailed G-code or macro instructions for utilizing the probe's functions.

5. Maintenance

Regular maintenance ensures the longevity and accuracy of your Marposs Q4124015000 Tool Eye Q Setter Head.

5.1 Cleaning

  • Periodically clean the probe's contact surface and body to remove coolant, chips, and other debris. Use a soft, lint-free cloth and a mild, non-abrasive cleaning solution if necessary.
  • Ensure no liquid enters the probe's internal components.

5.2 Inspection

  • Regularly inspect the probe for any signs of wear, damage, or loose connections.
  • Check the stylus for any bending, chipping, or contamination that could affect measurement accuracy.
  • Verify the integrity of the 6-pin cable and its connectors.

5.3 Recalibration

  • Recalibrate the probe periodically, or if you suspect any loss of accuracy, after significant machine maintenance, or if the probe has been subjected to impact.
  • Follow the calibration procedures outlined in your CNC machine's manual.

Always power off the CNC machine before performing any physical maintenance on the probe.

6. Troubleshooting

This section provides guidance for common issues encountered with the Marposs Q4124015000 probe.

Problem Possible Cause Solution
Probe not responding / No signal Loose or damaged cable connection; Incorrect wiring; Probe malfunction; CNC control issue. Check 6-pin cable connections. Verify wiring against diagrams. Consult CNC machine manual for control diagnostics. If issues persist, contact support.
Inaccurate measurements / Poor repeatability Contaminated stylus or probe surface; Loose mounting; Probe out of calibration; Damaged stylus. Clean probe and stylus. Ensure probe is securely mounted. Perform recalibration. Inspect stylus for damage and replace if necessary.
Tool integrity check fails unexpectedly Incorrect tool path; Tool not positioned correctly; Probe out of calibration; Actual tool damage. Verify CNC program for correct tool path and approach. Check tool for actual damage. Recalibrate the probe.

For complex issues or if troubleshooting steps do not resolve the problem, contact Marposs technical support or your authorized service provider.

7. User Tips

  • Environmental Control: Maintain a clean and stable environment around the CNC machine to minimize dust and temperature fluctuations, which can affect probe accuracy.
  • Regular Calibration: Implement a routine calibration schedule, even if no issues are apparent, to ensure consistent precision over time.
  • Gentle Handling: Treat the probe as a precision instrument. Avoid impacts or excessive force during handling, installation, or maintenance.
  • Documentation: Keep detailed records of calibration dates, maintenance performed, and any troubleshooting steps taken. This can help diagnose recurring issues.

8. Warranty and Support

8.1 Product Warranty

The Marposs Q4124015000 Tool Eye Q Setter Head comes with a 12-month warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, unauthorized modifications, or normal wear and tear. Please retain your proof of purchase for warranty claims.

Certifications for industrial products
Figure 5: Example certifications for industrial products, indicating adherence to quality standards.

8.2 Technical Support

For technical assistance, specific datasheets, or any inquiries regarding the Marposs Q4124015000, please do not hesitate to contact your supplier or Marposs authorized service center. Our team is available to provide expert support and guidance.

Contact information can typically be found on your purchase invoice or the official Marposs website.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.