SINOTIMER WPS101-63A/ WPS102-63A/ WPS103-63A

SINOTIMER Smart WiFi Circuit Breaker

Models: WPS101-63A, WPS102-63A, WPS103-63A

User Instruction Manual

1. Introduction

This manual provides detailed instructions for the installation, setup, operation, and maintenance of your SINOTIMER Smart WiFi Circuit Breaker. This device integrates advanced protection features with smart home connectivity, allowing for remote control and monitoring via the Tuya Smart Life app.

2. Safety Information

WARNING: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel.

  • Ensure the main power supply is disconnected before installation or maintenance.
  • Verify that the voltage and current ratings of the circuit breaker match your electrical system requirements.
  • Do not operate the device if it is damaged or malfunctioning.
  • This device is designed for indoor use only.
  • EU LVD Voltage: High voltage (Above 50Vac or 75Vdc).

3. Product Overview

The SINOTIMER Smart WiFi Circuit Breaker comes in three models, each offering a different set of features:

Three models of SINOTIMER Smart WiFi Circuit Breakers (WPS101, WPS102, WPS103) with a smartphone showing the Smart Life app interface.
Overview of the SINOTIMER Smart WiFi Circuit Breaker models and app integration.

Model Features Comparison

Table comparing features of V Protect, VA Protect, and VA Protect + kWh models.
Feature comparison across the three models.
Table 1: Model Feature Breakdown
FeatureWPS101 (V Protect)WPS102 (VA Protect)WPS103 (VA Protect + kWh)
LED Digital Display
Over/Under Voltage Protection
Over Current Protection
kWh Energy Monitoring
Voltage Display
Current Display
Timer Function
Remote Control
Power Failure Memory

Product Dimensions

Diagram showing product dimensions: 82mm height, 18mm width, 45mm depth, 51mm length of base, 35mm height of base.
Dimensions of the circuit breaker (approx. 82mm H x 18mm W x 45mm D).

4. Installation

The device features a top-in bottom-out wiring method, designed to prevent space congestion and facilitate convenient wiring.

Wiring diagram showing live wire (L) and neutral wire (N) connected to the IN terminals at the top, and OUT terminals at the bottom connected to a light bulb. The device is labeled WPS-103.
Top-in bottom-out wiring method.
  1. Ensure the main power supply is OFF before starting installation.
  2. Connect the Live wire (L) to the 'IN L' terminal and the Neutral wire (N) to the 'IN N' terminal at the top of the circuit breaker.
  3. Connect the load's Live wire to the 'OUT L' terminal and the load's Neutral wire to the 'OUT N' terminal at the bottom of the circuit breaker.
  4. Securely fasten all wire connections.
  5. Mount the circuit breaker on a DIN rail.

5. Smart App & WiFi Setup

This device connects to your home WiFi network via the Tuya Smart Life app. Only 2.4GHz WiFi networks are supported.

Video demonstrating WiFi connection and app features.

5.1. Network Distribution Operations (Connecting to WiFi)

  1. Power On: Power on the device by connecting it to the circuit breaker.
  2. Network Indicator: After the device is powered on, the network indicator light (the last decimal point of the first row of digital tubes) will flash slowly, indicating it has entered distribution network mode.
  3. APP Operation:
    1. Open the Tuya Smart Life app.
    2. Click on the "+" icon on the homepage and select "Add Device".
    3. The app will automatically scan for nearby devices.
    4. Once the device is discovered, click "Add" and enter your WiFi password as prompted.
  4. Successful Connection: The indicator light will change from slow flashing blue to a constant blue light.

5.2. Unbind Devices and Reset WiFi Network

Method 1: Reset on the APP (when the device is already bound)

  1. Navigate to the APP device page.
  2. Click on the edit (pencil) icon in the upper right corner.
  3. Select "Delete Device" and confirm the action.

Method 2: Device Reset (Universal)

  1. Ensure the screen is lit up (short press the button to wake up).
  2. Long press the device's ON/OFF button for 4 seconds.
  3. Observe the screen to display a scrolling display from top to bottom.
  4. When the indicator light returns to slow flashing, the reset is successful.

6. Operating Instructions

6.1. Manual ON/OFF & Remote Control

  • Manual Control: Press the physical ON/OFF button on the device to toggle power.
  • Remote Control: Use the Tuya Smart Life app to remotely turn the circuit breaker ON or OFF from anywhere.

6.2. Timer Function

The app allows you to set schedules for the circuit breaker to turn ON or OFF at specific times. This is useful for automating lighting, appliances, or other connected devices.

6.3. Overvoltage/Undervoltage/Overcurrent Protection Settings

You can customize protection thresholds and delays via the app:

  1. Open the Tuya Smart Life app.
  2. Enter the device control page of the circuit breaker.
  3. Click on "Settings" in the upper right corner.
  4. Enter "Alarm Settings".

Customizable Items:

  • Overcurrent Alarm: Enable/disable automatic disconnection and set the overcurrent threshold.
  • Overvoltage Alarm: Enable/disable automatic disconnection and set the overvoltage threshold.
  • Undervoltage Alarm: Enable/disable automatic disconnection and set the undervoltage threshold.

6.4. Auto Recovery

The device is designed to automatically recover and restore power once voltage or current conditions return to safe levels after a protection trip.

6.5. Energy Monitoring (WPS103 only)

The WPS103 model provides real-time energy consumption data (kWh) via the LED display and the Smart Life app. The app records usage data by day, month, and year.

6.6. LED Display Panel

The LED display shows real-time voltage, current, and kWh (for WPS103). It features a true RMS voltage monitoring display for highlight and easy reading.

Screen Shutdown:

The device screen will automatically shut down after 3 minutes of inactivity (no button presses or app control) to save power.

Wake Up Screen:

  • Device side: Press the physical button on the circuit breaker.
  • APP end: Go to the device control page → click on "Settings" in the upper right corner → enter "Parameter Settings" → find the "Digital Display" switch to turn on/off.

Network Indicator Light Status:

Indicator Light StatusMeaning
Flash (3 seconds)Waiting to connect to WiFi (network mode)
Constant BlueConnecting/Connected to network
ExtinguishThe network connection is stable and normal

Electricity Display Rules (WPS103 only):

  • When cumulative electricity consumption is ≤999kWh, the normal display value is shown (e.g., 888kWh).
  • When cumulative electricity consumption exceeds 999 kWh (e.g., 1234kWh):
    1. The screen will first display values in thousands of digits or higher (e.g., 1 represents 1000kWh).
    2. Pause for about 1 second.
    3. Display values in the hundreds and below (e.g., 234 represents 234 kWh).
    4. Pause for about 2-3 seconds.
    5. Repeat steps 1-4 in a cyclic polling display.

6.7. Power Failure Memory

The device retains its last state (ON/OFF) and settings after a power outage, ensuring seamless operation upon restoration of power.

7. Maintenance

  • Keep the device clean and free from dust and moisture.
  • Regularly check wiring connections for tightness and signs of wear.
  • Do not use abrasive cleaners or solvents on the device.
  • Ensure proper ventilation around the device to prevent overheating.

8. Troubleshooting

  • Device not connecting to WiFi: Ensure your WiFi network is 2.4GHz. Try resetting the device (long press ON/OFF button for 4 seconds) and re-pairing through the app.
  • App shows no data or timeout: Update the app to the latest version, remove the device from the app, re-pair it, and reboot the device.
  • Relay status memory function not found in app: Some firmware versions may have removed this feature. Ensure your app and device firmware are up to date. If the issue persists, consult the manufacturer's support.
  • Device not turning ON/OFF: Check power connections. If using remote control, ensure the device is connected to WiFi and the app is functioning correctly.
  • Protection features not triggering: Verify that the alarm thresholds and delay times are correctly set in the app's "Alarm Settings".

9. Specifications

AttributeValue
Brand NameSINOTIMER
Model NumberWPS101-63A/ WPS102-63A/ WPS103-63A
TypeMini Circuit breaker
Is Smart DeviceYes
Rated VoltageAC 220/230V
Frequency50/60Hz
Rated Current(1-40)A
Max Over-Current63A
Over-Voltage Range230-300V
Under-Voltage Range80-210V
InstallationDin Rail
PhaseSingle Phase
AppTuya&Smart Life
OriginMainland China
CertificationCE
EU LVD VoltageHigh voltage: Above 50Vac or 75Vdc

10. User Tips

  • For optimal performance and to avoid connectivity issues, ensure your WiFi router is configured to use a 2.4GHz band for smart devices.
  • Regularly check the Tuya Smart Life app for firmware updates to ensure you have the latest features and bug fixes.
  • If you experience unexpected behavior, a device reset (Method 2 in Section 5.2) can often resolve issues.

11. Warranty & Support

For detailed warranty information and technical support, please refer to the official SINOTIMER documentation or contact your retailer. A comprehensive user manual in PDF format is available for download from the product page: SINOTIMER Smart WiFi Circuit Breaker User Manual (PDF).

Related Documents - WPS101-63A/ WPS102-63A/ WPS103-63A

Preview SINOTIMER WiFi Smart Switch Instruction Manual
Comprehensive instruction manual for the SINOTIMER WiFi Smart Switch, detailing network setup via the Graffiti Smart APP, device unbinding and reset procedures, indicator light status, electricity consumption display, and configuration of overvoltage, undervoltage, and overcurrent protection settings.
Preview SINOTIMER SVP719 User Manual: Voltage Protector, Energy Meter, and Power Consumption Monitor
Comprehensive user manual for the SINOTIMER SVP719, detailing its features as an adjustable over/under voltage protector, surge protector, over-current limit relay, and a Watt/kWh energy meter for monitoring power consumption.
Preview SVP-916 Intelligent Over-Voltage Limit Current Protector Instruction Manual
Instruction manual for the SINOTIMER SVP-916 intelligent over-voltage, under-voltage, and over-current protector for single-phase AC 230V systems. Details features, parameters, and setting methods for electrical equipment protection.
Preview SINOTIMER DDS6619 Series Guide Rail Metering Switch Instruction Manual
Instruction manual for SINOTIMER DDS6619 series guide rail type metering switches. Details technical specifications, wiring, app control via Smart Life/Tuya, operating instructions, and safety precautions for smart energy monitoring.
Preview SINOTIMER DTS6619 3 Phase Energy Meter | 100A DIN Rail kWh Monitor
Detailed overview of the SINOTIMER DTS6619 3 Phase Energy Meter. Features 100A capacity, DIN rail mounting, LCD display, high accuracy, and MODBUS-RTU RS485 interface for monitoring kWh, voltage, current, and power.
Preview SINOTIMER TM-630A/TM-630S Digital Timer: Features and Specifications
Detailed technical specifications and features for the SINOTIMER TM-630A and TM-630S digital programmable timers, including power supply, timing range, dimensions, and wiring.