TOOLTOP TH202

Contents

TOOLTOP TH202 4-in-1 Thermal Imager Oscilloscope Multimeter Signal Generator User Manual

Model: TH202 | Brand: TOOLTOP

1. Introduction

The TOOLTOP TH202 is a versatile 4-in-1 handheld device integrating a professional thermal imager, a dual-channel oscilloscope, a 20,000-count True-RMS multimeter, and a signal generator. Designed for a wide range of applications, from PCB inspection to automotive electrical diagnostics, this instrument provides comprehensive measurement and analysis capabilities in a compact form factor.

TOOLTOP TH202 4-in-1 device showing thermal imaging, oscilloscope, multimeter, and signal generator modes
Figure 1.1: The TOOLTOP TH202 device highlighting its four main functions.
Video 1.1: An overview of the TH202's features and functions.

2. Safety Information

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always inspect the device and accessories for any damage before use. Do not use if damaged.
  • Ensure proper connections are made before applying power or taking measurements.
  • Do not exceed the maximum input ratings for any function.
  • Use caution when working with live circuits.
  • Keep the device dry and clean.
  • Do not attempt to open or modify the device. Refer all servicing to qualified personnel.

3. Package Contents

Verify that all items listed below are included in your package:

  • 1 x TOOLTOP TH202 Thermal Imager Oscilloscope Multimeter
  • 2 x Oscilloscope Probes
  • 1 x One Pair Test Leads (Dual-color)
  • 1 x BNC to Alligator Clip Cable (Signal Output Cable)
  • 1 x USB Cable
  • 1 x EVA Bag
  • 1 x English User Manual
Image showing all included accessories: TH202 device, printed box, EVA bag, instruction manual, dual-color test lead, oscilloscope probes, signal output cable, USB charging cable.
Figure 3.1: Contents of the TH202 package.

4. Device Overview

The TH202 features a robust design with a 3.2-inch TFT color screen and intuitive controls. Key components include:

  • Display: 3.2-inch TFT color screen with 320x240 resolution.
  • Control Buttons: Navigation, mode selection (IR, DMM, OSC, AWG), save, menu, and power buttons.
  • Input/Output Ports: BNC connectors for oscilloscope and signal generator, multimeter input jacks (10A, COM, VΩCap).
  • Thermal Camera Lens: Located on the back, with a convertible macro lens for close-up inspections.
  • USB Port: For charging and data transfer.
Front view of the TOOLTOP TH202 device, showing the screen and control buttons.
Figure 4.1: Front view of the TH202.
Back view of the TOOLTOP TH202 device, showing the thermal camera lens and convertible macro lens.
Figure 4.2: Back view of the TH202 with macro lens.

5. Setup and Initial Use

5.1 Charging the Battery

The device is powered by a 3000mAh rechargeable lithium battery. Connect the included USB cable to the device's USB port and a DC5V/2A power adapter (not included) to charge. The battery indicator on the screen will show charging status.

5.2 Powering On/Off

Press and hold the red power button to turn the device ON or OFF.

5.3 Macro Lens Usage

The TH202 includes a convertible macro lens pre-installed for close-range PCB inspection (approximately 3 cm). For measurements beyond this distance, ensure the macro lens is disengaged or use normal thermal imaging mode to avoid blurred images.

Comparison of thermal images with macro lens turned on and off, showing clearer detail for PCB inspection with the macro lens.
Figure 5.1: Macro lens comparison for PCB inspection.

6. Operating Modes

The TH202 features four primary operating modes, accessible via dedicated buttons on the front panel: IR (Thermal Imager), DMM (Multimeter), OSC (Oscilloscope), and AWG (Signal Generator).

6.1 Thermal Imager (IR) Mode

Press the IR button to enter thermal imaging mode. This mode utilizes a 256x192 resolution, 25Hz thermal imaging sensor to visualize temperature distributions.

  • Palettes: The device offers 15 pseudo-color display options (e.g., White Hot, Black Hot, Fusion, Iron, Deep Blue, Lava, Rain, Green, Red Hot, Deep Purple) to suit different inspection needs. Navigate through palettes using the arrow keys.
  • Image Modes: Supports various image modes for different viewing preferences.
  • Temperature Measurement: Displays global maximum, center region maximum/minimum, center point temperature, and temperature change curve. High/Low temperature alarms can be configured.
  • Photo/Video Recording: Capture thermal images (JPG) and videos (AVI) for analysis. Use the SAVE button to store data.
TOOLTOP TH202 in thermal imaging mode, showing temperature readings and a thermal map of an electronic component.
Figure 6.1: Thermal Imager mode displaying temperature distribution.
Thermal imager screen showing various automatic temperature measurement points like global max, center region max/min, center point, and high/low temperature alarm.
Figure 6.2: Automatic Temperature Measurement features.
Display showing 15 different thermal palettes for various visualization needs.
Figure 6.3: 15 Thermal Palettes for diverse scenarios.
Screen showing options for saving photos and recording videos in thermal imaging mode.
Figure 6.4: Supported Photo and Video Recording.

6.2 Oscilloscope (OSC) Mode

Press the OSC button to enter oscilloscope mode. This device features a dual-channel oscilloscope with an 80MHz analog bandwidth (single channel) or 40MHz (dual channel) and a 200MSa/s sampling rate.

  • Connecting Probes: Connect oscilloscope probes to the BNC connectors at the top of the device.
  • Waveform Display: Observe real-time waveforms. Use navigation buttons to adjust time base, vertical sensitivity, and other parameters.
  • Automatic Adjustment: The device supports fast auto-adjustment for clear signal display.
  • Measurement Parameters: Displays 12 customizable waveform parameters including Vp-p, Vmax, Vmin, Vavg, Vrms, Freq, Period, +Width, -Width, +Duty, -Duty.
  • Storage: Stores up to 2,000 waveform records.
TOOLTOP TH202 connected to an external signal source, displaying dual-channel waveforms on its screen.
Figure 6.5: Dual-channel oscilloscope in action.
Oscilloscope screen showing 2CH oscilloscope, automatic adjustment, and storage for 2000 waveform records and multimeter data.
Figure 6.6: Oscilloscope features including automatic adjustment and data storage.
Oscilloscope screen displaying 12 different measurement parameters like Freq, Period, Width, Duty, Vmax, Vmin, Vavg, Vrms.
Figure 6.7: Display of 12 Measurement Parameters in Oscilloscope mode.

6.3 Multimeter (DMM) Mode

Press the DMM button to enter multimeter mode. This is a 20,000-count True-RMS multimeter.

  • Connecting Test Leads: Connect the dual-color test leads to the appropriate input jacks (COM, VΩCap, 10A).
  • Measurement Functions: Supports DC/AC voltage, DC/AC current, resistance, capacitance, frequency, duty cycle, diode test, and continuity test.
  • Auto Ranging: The device automatically selects the appropriate range for measurements.
  • Data Display: Real-time measurement data, maximum/minimum values, data hold, and relative value measurements are displayed.
  • Storage: Stores up to 2,000 multimeter data sets.
Multimeter screen showing various measurement functions like AC/DC voltage, current, resistance, capacitance, diode, continuity, duty cycle, and frequency.
Figure 6.8: Multimeter mode display with various functions.
Multimeter interface display showing auto range, max/min, input interface, high voltage warning, function type, data hold icon, AC/DC indication, real-time measurement data, and relative value.
Figure 6.9: Detailed Multimeter Interface Display.

6.4 Signal Generator (AWG) Mode

Press the AWG button to enter signal generator mode. This mode allows you to output various waveforms.

  • Connecting Output Cable: Connect the BNC to Alligator Clip Cable to the 'Gen Out' BNC connector.
  • Waveform Selection: Generate Sine Wave (10Hz-100kHz), Triangle Wave (10Hz-100kHz), and Square Wave (10Hz-4MHz).
  • Duty Cycle: For Square Wave, the duty cycle is adjustable from 10%-90% in 10% increments.
  • Output Voltage: The output voltage is 3Vpp (peak-to-peak) with an approximate 50Ω output impedance.
Signal generator screen showing sine, ramp (triangle), and square waveforms with their respective frequency ranges and output voltage.
Figure 6.10: Signal Generator waveforms and settings.

7. Troubleshooting

  • Thermal Image Non-Uniformity/Lag: The thermal imaging detector includes a mechanical control calibration plate. It calibrates every 10 seconds to ensure accurate measurements, which may cause a brief 1-2 second lag. This is normal operation.
  • Blurred Thermal Images: If thermal images appear blurred, especially for objects further away, ensure the macro lens is not engaged. The macro lens is designed for close-range PCB inspection (approx. 3 cm).
  • Device Beeping: To mute the device, select either the OSC or DMM mode, then press the MENU key. Navigate to the "Beep" function and turn it off.

8. Specifications

Category Parameter Value
General Specifications
DisplayResolution; Size320x240; 3.2-inch TFT color screen
Backlight BrightnessLevels1-8 levels adjustable
BatteryType; Capacity3000mAh rechargeable lithium battery
Operating TimeApproximateAbout 5 hours
Operating EnvironmentTemperature; Humidity0℃~+40℃; <75%RH
Overall DimensionsL x W x H173mm x 89mm x 38mm
WeightExcluding accessories296g (0.65 lb)
Auto Power-offSetting5min-60min or disabled
PowerInputDC5V/2A (charger not Included)
Storage CapacityDMM; OSCDMM: 2000 records; OSC: 2000 waveforms
Storage EnvironmentTemperature; Humidity-10℃~+60℃; <90%RH
Thermal Imaging Features
Sensor TypeVOx (Vanadium Oxide)
Thermal Resolution256x192
Image Capture Rate25Hz
Temperature Range-20°C~+550°C
Measurement Accuracy±2°C or ±2%
Emissivity0.01~0.99
PaletteWhite Hot, Black Hot, Fusion1, Fusion 2, Iron 1, Iron 2, Deep Blue, Color 1, Color 2, Lava, Rain, Green, Red Hot, Deep Purple
Field of View (FOV)50.0°(H)x37.2°(V)
Focus3.5mm (fixed, non-adjustable)
Measurement Points5 (center, highest, lowest, area max, area min)
Image FormatJPG (photo), AVI (video)
Storage CapacityTF card
Oscilloscope Features
Analog Bandwidth80MHz (Single Channel), 40MHz (Dual Channel)
Maximum Sampling Rate200MSa/s
Channels2
Storage Depth2K
Vertical Resolution8 bits
Coupling ModeDC, AC
Input ImpedanceApprox. 1MΩ
Trigger ModeAuto, Normal, Single
Trigger Edge SelectionRising / Falling edge
Vertical Sensitivity Range10mV/div - 10V/div
Vertical Accuracy±(5% + 0.2div)
Voltage Measurement ParametersVp-p, Vp, Vmax, Vmin, Vavg, Vrms
Time Measurement ParametersFreq, Period, +Width, -Width, +Duty, -Duty
Non-Linearity±1 bit
AttenuationVertical ±4.0, Horizontal ±6.0
Time Base Range6ns/div - 50s/div (adjustable in 1-2-5 steps)
Horizontal Accuracy±(0.01% + 0.1div)
Automatic Measurement Accuracy±(5% + 0.2div)
Multimeter Parameters
DisplayCounts20000 Counts
DMM Measurement Speed3 times/second
DC VoltageRange200.00mV / 2.0000V / 20.000V / 200.00V / 1000.0V
AC Voltage (True RMS)Range200.00mV / 2.0000V / 20.000V / 200.00V / 750.0V
DC CurrentRange2000.0mA / 10.000A
AC Current (True RMS)Range2000.0mA / 10.000A
ResistanceRange200.00Ω / 2.0000kΩ / 20.000kΩ / 200.00kΩ / 2.0000MΩ / 20.000MΩ / 200.00MΩ
CapacitanceRange9.999nF / 99.99nF / 999.9nF / 9.999uF / 99.99uF / 999.9uF / 9.999mF / 99.99mF
FrequencyRange9.999Hz - 9.9999MHz (input ≥ AC 500mVp-p)
Diode TestOpen-circuit voltage approx. 3V, max test current approx. 2mA
Continuity TestBuzzer sounds at <50Ω; displays OL at ≥200Ω
Auto Range SwitchingApplicable to all measurement functions
Overrange IndicationO.L (Over load)
Dynamic Data WindowContinuously refreshes to display real-time measurement data
Fuse10A/250V
Signal Source Parameters
Waveform FrequencySine Wave10Hz-100kHz (1-2-3-5 step mode)
Triangle Wave10Hz-100kHz (1-2-3-5 step mode)
Square Wave10Hz-4MHz (5MHz for reference only) (1-2-3-5 step mode)
Square Wave Duty Cycle10%-90% (adjustable in 10% increments, 1-2-3-5 step mode)
Output Voltage3Vpp (output impedance approx. 50Ω)
Table of General, Thermal Imaging, and Oscilloscope Technical Parameters.
Figure 8.1: Technical Parameters (Part 1).
Table of Multimeter and Signal Source Technical Parameters.
Figure 8.2: Technical Parameters (Part 2).

9. Maintenance

  • Cleaning: Use a soft, damp cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: For long-term storage, charge the battery to approximately 50% every three months to maintain battery health.

10. User Tips

  • For precise thermal imaging of small components, remember to use the macro lens and position the device approximately 3 cm from the target.
  • When using the oscilloscope, utilize the auto-adjustment feature for quick and clear waveform display.
  • Take advantage of the 4GB built-in storage to save important thermal images, videos, and measurement data for later analysis and reporting.
  • Explore the various thermal palettes to find the best visualization for different temperature contrasts and applications.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or the manufacturer's official website. Keep your proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.