1. Overview
The NJTY T6015 Pointer Insulation Resistance Meter is a professional, handheld insulation resistance tester (megohmmeter) designed for electricians and technicians to verify the integrity of wiring and electrical insulation. It provides reliable performance for a wide range of electrical testing and maintenance applications. This classic analog insulation tester is your reliable partner for critical measurements.
The T60 series pointer-type insulation testers, including models T6015, T6010, and T6005, feature a modern design, compact size, and portability. They are fully functional, highly accurate, and easy to operate reliably. The T6015 supports 3-range insulation testing and AC/DC voltage testing. These products are suitable for measuring the insulation resistance of various electrical equipment and insulating materials, such as transformers, motors, cables, switches, and appliances. They are ideal for routine maintenance, testing, and verification of electrical equipment.
Powered by a 18650 rechargeable battery, it can be used to charge mobile phone chargers, power banks, and car chargers in urgent need of charging, which solves the shortcoming of the electronic insulation meter battery being not durable. The back cover has a magnetic suction function, which can be adsorbed on the iron cabinet when in the attached cabinet operation mode, freeing up your reference, and is a must-have artifact for veteran electricians.
2. Safety Rules and Precautions
This manual contains instructions and safety terms that users must adhere to in order to ensure safe operation and maintenance of the instrument. Please read these operating instructions carefully before using the instrument.
The symbol "▲" on the instrument indicates that users must follow the relevant safety instructions in this manual. Pay special attention to the safety rules and warning notes in this manual to avoid electric shock and damage to the instrument.
- Read this manual carefully before use.
- Do not use the instrument if the battery cover is not securely closed, as this poses an electric shock hazard.
- Before use, ensure the test leads' insulation is intact and undamaged.
- To avoid damaging the instrument, perform insulation measurements only on disconnected circuits.
- Do not press the "Test Button" when measuring voltage.
- To avoid electric shock, do not touch the test leads or the circuit being tested during measurement.
- Avoid touching the tested circuit immediately after testing, as residual charge may cause electric shock.
- Do not modify the internal circuitry. If a malfunction occurs, contact us for assistance.
Electrical Symbols
- ACV: AC voltage
- DCV: DC voltage
- ▲: Warning / High Voltage Hazard
- ⎈: Auto Discharge / Withstand voltage test
- ⎈: Low resistance alarm
3. Panel Diagram
- Charging indicator light
- Work indicator light
- Gear position rotary switch (T6015 model)
- EARTH input terminal (connected to the ground terminal of the circuit under test)
- LINE input terminal (connected to the circuit under test)
- Test button
- Pointer zero adjustment
- Insulation meter reading dial
4. Technical Specifications
| Parameter | Details (T6015) | Details (T6005) | Details (T6010) |
|---|---|---|---|
| Rated Test Voltage | 100V, 500V, 1000V | 500V | 1000V |
| Low-Resistance Alarm | <2MΩ (100V), <1MΩ (500V), <200KΩ (1000V) | <2MΩ | <2MΩ |
| Transistor Withstand Voltage Test | 100V, 500V, 1000V | 500V | 1000V |
| Output Short-Circuit Current | Max 0.75 mA | Max 0.65 mA | Max 1.3 mA |
| Measurement Range | 0-2000MΩ | 0-1000MΩ | 0-2000MΩ |
| Measurement Accuracy | 1M-2000MΩ ±10% | 1M-1000MΩ ±10% | 1M-2000MΩ ±10% |
| Voltage Measurement Range | DCV500V, 50V; ACV500V (50Hz) | ACV500V (50Hz) | ACV500V (50Hz) |
| Insulation Test Output Voltage | 90%-120% of Rated Voltage | ||
| Discharge Resistor | 10MΩ | ||
| Voltage Measurement Error | ±5% (Full Scale) | ||
| Battery Testing | 3.3V Low Voltage Indication | ||
| Insulation | Between the movement circuit and the case: >50MΩ | ||
| Dimensions | 161 x 96 x 45 mm | ||
| Weight | Approximately 534 g (including accessories) | ||
| Powered Battery | 1x 3.7V 18650 rechargeable lithium battery | ||
5. Setup
5.1 Mechanical Zero Adjustment
Before starting insulation measurement, check whether the pointer is consistent with the "∞" (zero position on the left) mark on the insulation meter scale. If not, use a screwdriver to rotate the "pointer zero adjustment" on the meter to adjust the zero position.
5.2 Test Lead Connection
Insert the red and black test leads into the L and E ports of the meter respectively.
6. Operation Instructions
6.1 Insulation Resistance Measurement
Press and hold the "test button" for 1 second to turn on the meter. The green "working" indicator light on the upper right corner of the dial will light up. After normal startup, it will automatically shut down after 15 minutes. Press the "test button" three times within 5 seconds after powering on, the meter switches to continuous working state, and the two green indicators in the upper right corner light up, and the automatic shutdown function is canceled. You can manually shut down the meter 5 seconds after powering on, and press and hold for 1 second to shut down. When working in the undervoltage state, the working indicator light is red, and it will automatically shut down after 15 minutes.
After the insulation measurement is started, the test leads touch the insulator to be measured and read the measured value according to the pointer scale.
6.2 AC and DC Voltage Measurement
The T6015 needs to be switched to the corresponding voltage range for measurement, while the T6010 and T6005 can be measured directly. Confirm that no insulation measurement has been started (i.e., the working indicator light is not on). Use the test leads to touch the two ends of the voltage to be measured and read the measured value according to the pointer scale.
Note: When T6015 measures DC voltage, insert the red test lead into "+" and the black test lead into "-".
6.3 Transistor Withstand Voltage Measurement
Connect the transistor to be tested to the meter according to polarity. Press the test button to directly read the BV(V) voltage scale. The read value is the withstand voltage of the transistor (the DC load voltage value L(V) at both ends of the material being tested).
The maximum withstand voltage measurement value of T6015 and T6010 insulation meters is 1000V. The maximum withstand voltage measurement value of T6005 insulation meter is 500V.
6.4 Battery Performance Test
The meter can be used to test the performance of batteries. Connect the battery to the test leads and observe the reading on the dial.
7. Charging and Battery Replacement
To prevent electric shock, please remove the test leads from the instrument before charging or replacing batteries.
When the instrument is working normally, the working indicator light is green, indicating that the battery is sufficient. When the working indicator light is red, it means that the battery power supply is undervoltage, prompting that charging or replacement of batteries is required.
Use a 5V USB power supply (including power bank and car charger, etc.), and the charging interface of the instrument is Type-C.
The charging indicator light turns red during charging and automatically turns green when fully charged. Do not start the test during charging.
If the battery fails, please replace it with a battery of the same specification (1x 3.7V 18650 rechargeable lithium battery).
8. Maintenance
This instrument is a precision electronic device and should be maintained with care.
- If the instrument is not used for an extended period, recharge it every two months.
- Store the instrument in a dry place and avoid humid environments.
- Avoid strong vibrations or impacts, as they may damage the meter head or circuitry.
- Do not modify the internal circuitry. If a malfunction occurs, contact us for assistance.
9. Troubleshooting
If you encounter issues with your NJTY T6015 meter, consider the following:
- No Power/Display: Check battery charge level. Ensure the 18650 battery is properly inserted and charged. If the working indicator light is red, the battery is low and needs charging.
- Inaccurate Readings: Perform mechanical zero adjustment as described in Section 5.1. Ensure test leads are securely connected and undamaged. Verify that the correct measurement range is selected for voltage tests.
- Low Resistance Alarm: The meter features a low resistance buzzer alarm. If the measured resistance is below the alarm setting value, the buzzer will sound, indicating a potential issue with the circuit under test.
- Meter Shuts Off Unexpectedly: The meter has an automatic shutdown feature after 15 minutes of inactivity. If it shuts off during continuous use, ensure it's in continuous working mode (press the test button three times within 5 seconds after powering on). If the working indicator light is red, it may be due to low battery voltage.
- No Output Voltage during Insulation Test: Ensure the "Test" button is pressed and held for the duration of the test. Check battery level.
For persistent issues not covered here, please contact customer support.
10. User Tips
- Utilize Portability: The meter's integrated strap holes and magnetic back allow for hands-free operation. Use a shoulder strap (not included) for aerial work or mount it magnetically to metal surfaces for convenience.
- Monitor Battery Status: Pay attention to the working indicator light. Green indicates sufficient battery, while red signals low battery, prompting a recharge.
- Understand Analog Readings: The analog pointer provides instantaneous response, which is excellent for observing trends and momentary breakdowns in real-time, unlike digital meters that show static values.
- Use Alligator Clips: For stable and secure connections during testing, especially for insulation resistance, utilize the provided alligator clips with the test leads.
11. Package Contents
- T60 Series Insulation Resistance Tester x 1
- Portable Tool Bag x 1
- Insulation Resistance Tester Test Leads x 1 pair
- User Manual x 1
- 18650 Rechargeable Lithium Battery x 1
- USB Charging Cable x 1
12. Warranty and Support
This product is covered by a manufacturer's warranty against defects in materials and workmanship. For warranty claims or technical support, please refer to the contact information provided with your purchase or on the official NJTY website.
Please retain your proof of purchase for warranty purposes.