TZONE RD07_4G LoRa Gateway and Sensor System User Manual

Comprehensive guide for installation, operation, and maintenance.

1. Introduction

The TZONE RD07_4G LoRa Gateway and Sensor System is designed for efficient and reliable temperature and humidity monitoring in various environments, particularly warehouses. This system leverages 4G and LoRa technologies to provide long-distance data transmission and robust performance. This manual provides essential information for setting up, operating, and maintaining your device.

Play video
Watch video online

Video: Overview of the TZONE LoRa Gateway and Sensors.

2. Product Components

The TZONE RD07_4G system typically includes the LoRa Gateway and compatible LoRa Temperature and Humidity Sensors. Key components of the gateway are:

  • LoRa Gateway Unit: The central hub for data collection and transmission.
  • Antennas: For 4G and LoRa communication.
  • Power Adapter: DC12V for powering the gateway.
  • USB Cable: For configuration.
LoRa Gateway RD07_4G with single antenna
Figure 1: LoRa Gateway RD07_4G with single antenna.
LoRa Gateway RD07_4G with dual antennas
Figure 2: LoRa Gateway RD07_4G with dual antennas.
LoRa Gateway RD07_4G with dual antennas and two sensors
Figure 3: LoRa Gateway RD07_4G connected to two sensors (one with external probe, one with internal sensor).
Close-up of LoRa Gateway RD07_4G and two sensors
Figure 4: Close-up view of the LoRa Gateway RD07_4G and two sensors.

3. Setup Instructions

3.1. Gateway Installation

  1. Mounting: Securely mount the LoRa Gateway in a central location within the monitoring area, ensuring good signal reception for both 4G and LoRa. The device features mounting holes for easy installation.
  2. Antenna Connection: Connect the provided antennas to the designated RF ports on the gateway. Ensure they are tightened securely.
  3. Power Connection: Connect the DC12V power adapter to the gateway's power input. Ensure the ON/OFF switch is in the OFF position before connecting.
  4. SIM Card Installation (for 4G models): Insert a valid 4G SIM card into the SIM card slot (if applicable for your model).
  5. Initial Power On: Flip the ON/OFF switch to the ON position. Observe the Power, NET, and RF indicator lights.

3.2. Sensor Deployment

Deploy the LoRa Temperature and Humidity Sensors in strategic locations within the warehouse or monitoring area. Ensure sensors are placed where they can accurately measure the environmental conditions and are within the 5KM maximum range of the gateway in open areas.

3.3. Configuration

The gateway can be configured via USB or SMS.

  • USB Configuration: Connect the gateway to a computer using a USB cable. Use the provided software (refer to software manual for details) to configure parameters such as transmit interval, alarm thresholds, and network settings.
  • SMS Configuration: For remote configuration, send specific SMS commands to the gateway's 4G number. Refer to the SMS command list in the detailed technical documentation.

4. Operation

4.1. Indicator Lights

  • Power: Solid green when powered on.
  • NET: Indicates 4G network status. Blinking indicates network activity, solid indicates connected.
  • RF: Indicates LoRa communication status. Blinking indicates data transmission/reception.

4.2. Data Transmission

The gateway collects data from up to 100 sensor tags and transmits it via 4G to a designated server or platform at user-definable intervals (10 seconds to 6000 seconds).

4.3. Alarms

The system supports user-definable low voltage and temperature alarms. When thresholds are exceeded, the gateway can trigger alerts (e.g., SMS notifications, platform alerts) based on configuration.

5. Maintenance

  • Regular Cleaning: Keep the gateway and sensors clean and free from dust and debris to ensure optimal performance.
  • Battery Check: The gateway has a built-in 3.7V/850mAh rechargeable lithium battery for backup. Ensure it is charged and functioning correctly.
  • Firmware Updates: Periodically check for firmware updates from the manufacturer to ensure the system has the latest features and security patches.
  • Antenna Integrity: Ensure antennas are securely connected and undamaged for reliable signal transmission.

6. Troubleshooting

ProblemPossible CauseSolution
No Power IndicatorPower adapter disconnected or faulty; ON/OFF switch off.Check power adapter connection, ensure it's working. Flip ON/OFF switch to ON.
No NET IndicatorNo 4G signal; SIM card not inserted or faulty; incorrect APN settings.Check 4G signal strength. Reinsert SIM card. Verify APN settings via USB configuration.
No RF Indicator / No Sensor DataSensors out of range; sensor battery low; LoRa frequency mismatch.Relocate sensors closer to gateway. Check sensor batteries. Verify LoRa frequency settings on both gateway and sensors.
Inaccurate ReadingsSensor placement in extreme conditions; sensor faulty.Ensure sensors are placed in representative areas, away from direct heat/cold sources. Replace faulty sensor.

7. Specifications

ParameterValue
Product NameTZONE IOT Device 4G LoRa Gateway And Sensors Temperature Humidity Controller
Model NumberRD07 4G
ModulationLoRa
Interface4G/RS485/Modbus - RTU
RF Frequency433/470/868/915MHz (optional)
Working Temperature Condition-20°C ~ +60°C
Working Humidity Condition5%RH ~ 95%RH (non-condensing)
Maximum Range in Open Area5KM
Inner Lithium BatteryBuilt-in 3.7V/850mAh (rechargeable)
Power SupplyDC12V
Transmit Interval10sec ~ 6000sec (user definable)
Sensitivity of Receiving-148dBm
Low Voltage AlarmYes (user definable)
Temperature AlarmYes (user definable)
Dimensions11.2 x 10.5 x 2.7 cm
MaterialPlastic

8. User Tips

  • For optimal LoRa range, ensure a clear line of sight between the gateway and sensors. Obstructions like thick walls or metal structures can significantly reduce range.
  • When configuring, always save your settings before disconnecting the USB cable or restarting the device.
  • Consider using external antennas for sensors if they are deployed in challenging environments or at the edge of the communication range.
  • Regularly check the data on your monitoring platform to ensure continuous operation and accurate readings.

9. Warranty and Support

The TZONE RD07_4G LoRa Gateway and Sensor System comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use. For technical support, troubleshooting assistance, or warranty claims, please contact your vendor or the manufacturer's customer service.

Contact Information:

  • Email: maoyishunda@gmail.com
  • WhatsApp: +86 13367386608

© 2023 TZONE. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?