LEIRONG ZP600ST

Contents

LEIRONG ZP600ST Intelligent Peristaltic Pump

User Manual

1. Introduction

The LEIRONG ZP600ST is a precision intelligent peristaltic pump designed for accurate and reliable fluid transfer. Featuring an OLED display, stepper motor, and bidirectional flow capabilities, it is suitable for a wide range of demanding laboratory and industrial applications. This manual provides detailed instructions for the safe and efficient operation and maintenance of your ZP600ST pump.

Video: Overview of the LEIRONG ZP600ST Intelligent Peristaltic Pump, demonstrating its features and applications.

2. Product Overview

2.1 Key Features

  • OLED Display: Provides clear visibility for various operating modes and parameters.
  • Knob Control: Simple and intuitive operation for setting parameters and switching menu options.
  • Bidirectional Flow: Easily switch between forward and reverse rotation for flexible fluid transfer.
  • Stepper Motor: Ensures precise control and stable flow rates.
  • Multiple Operating Modes: Supports Continuous, Time Dispensing, Volume Dispensing, and Calibration modes.
  • Power-Off Memory: Retains the last operation data after power-off and restart.
  • Easy Tube Change: Designed for quick and convenient replacement of pump tubes.
  • Low Voltage Operation: Operates safely with a 24V DC power supply.

2.2 Application Fields

The ZP600ST pump is versatile and can be used in various applications, including:

  • Laboratory research
  • Analytical instruments
  • Water supply devices
  • Cleaning devices
  • Filling machines
  • Water circulation systems
  • 3D printing
  • Inkjet coding printing
  • Water quality sampling
  • Hydroponics
  • Food portioning
Diagram showing various applications of the peristaltic pump including laboratory, analyzer, cleaning device, filling machine, water circulation, and water supply device.

Image: Core strengths and diverse application fields of the ZP600ST pump.

3. Package Contents

Upon unpacking, please verify that all items listed below are present and in good condition:

  • ZP600ST Peristaltic Pump (1 unit)
  • DC Power Adapter (1 unit)
  • External Tube (2 meters)
  • Packaging Box
Image showing the ZP600ST Peristaltic Pump, DC power adapter, external tube, and packaging box.

Image: Contents included in the ZP600ST product package.

4. Specifications

4.1 General Specifications

Item Value
Model NumberZP600ST
BrandLEIRONG
TheoryRotary Pump
StructurePeristaltic Pump, Reduction gear
ApplicationMetering, Medical instruments, Experimental scientific research, Aquarium titration, Food machinery, Distribution filling
Power SourceElectric (100-240V AC Input)
Voltage24V
Motor TypeStepper motor
Control ModeKnob speed/timing/quantitative
PressureLow Pressure
Rollers Quantity3
Noise≤60dB
Power48W
Weight2070g
Lifetime8000H (Gear box: Independent research and development of long life)
MaterialPA66+PC\Stainless steel
OriginChina Mainland

4.2 Tube Specifications and Flow Rate

Tube Materials Norprene
Tube Species N40 N48
ID×OD4X7.24.8X8
Flow rate (ml/min)0.2-6000.4-800

Suggested working conditions: Ambient temperature 0-50°C, relative humidity <80%. The above data are all obtained from tests in LEIRONG's laboratory and are for reference only.

Flow testing method: Water test at room temperature 20 °C and atmospheric pressure. The above data is for reference only, and there may be deviations in flow rate depending on different liquids, pressures, and pipeline lengths. The material, flow rate, and control method of the pump tube can be customized according to the needs.

4.3 Product Dimensions

Dimensional drawing of the ZP600ST pump showing a length of 138mm, width of 94mm, and height of 107mm.

Image: Product dimensions (Length: 138mm, Width: 94mm, Height: 107mm).

5. Setup

5.1 Initial Connection

The ZP600ST pump is designed for 'Plug and Play' operation, making it simple and easy to use.

  1. Connect the provided DC power adapter to the pump's power input port.
  2. Plug the power adapter into a suitable electrical outlet (100-240V AC).
  3. Connect the external tubing to the inlet and outlet ports of the pump head. Ensure a secure fit to prevent leaks.
Image illustrating the 'Plug and Play' setup of the ZP600ST pump, showing the power adapter connected and tubing in place.

Image: Simple 'Plug and Play' setup for the ZP600ST pump.

6. Operating Instructions

6.1 Display and Controls

The ZP600ST features an OLED display and intuitive controls for easy operation.

Close-up of the ZP600ST pump's OLED display showing 'Menu', 'Alloc', 'Cal', and 'Config' options, with a knob for parameter adjustment.

Image: OLED Display and knob for parameter adjustment.

6.1.1 Knob Operation

  • Rotate the knob: To switch between menu options or adjust parameter values.
  • Press the knob: To confirm a selection, enter a menu interface, or exit a menu.
  • Yellow Highlight: Indicates a selected menu item.
  • Blue Highlight: Indicates a parameter that can be confirmed or entered.
  • Flashing Cursor: Indicates a parameter ready for adjustment.

6.1.2 Toggle Lever (CCW/CW Switch)

The toggle lever allows you to adjust the direction of flow:

  • Lever on the left: Counter-Clockwise (CCW) rotation, typically for 'Left In → Right Out' flow.
  • Lever on the right: Clockwise (CW) rotation, typically for 'Right In → Left Out' flow.
Diagram showing the ZP600ST pump with tubing set up for bidirectional conveying, with an inset showing the CCW/CW switch.

Image: Bidirectional conveying with CCW/CW switch.

6.2 Operating Modes

The ZP600ST offers four primary operating modes:

  • Continuous Mode: For continuous operation with cumulative runtime display and adjustable flow rate/speed.
  • Time Dispensing: Set liquid addition volume, interval time, and flow rate as needed.
  • Volume Dispensing: Set the allocation duration, interval time, and flow rate as needed.
  • Calibration Mode: Calibrate set vs. actual volume to reduce addition error.

6.2.1 Continuous Mode

In Continuous mode, the pump operates continuously, displaying the cumulative working time. You can adjust the flow rate/rotation speed as needed.

Schematic diagram of fluid operation in Continuous Mode, showing continuous flow through a tube.

Image: Continuous Mode Fluid Operation Schematic.

  • Continuous Run & Show Duration: Select this option, then press the knob to switch to the menu.
  • Operating Time: Select & press to start/stop. Display duration on run, reset to zero on stop.
  • Flow Rate: Show flow/min. Adjustable in run/stop mode. Select & press to adjust when flashing.
  • Rotation Speed: Show rotation speed. Adjustable in run/stop mode. Select & press to adjust when flashing.

6.2.2 Allocation Mode (Time-based Dispensing)

This mode allows you to set the allocation duration, interval time, and flow rate for precise dispensing.

Schematic diagram of fluid operation in Time-Based Allocation Mode, showing liquid addition time and interval time.

Image: Time-Based Allocation Mode Fluid Operation Schematic.

  • Dispensing: Select 'Time Dispensing' with the cursor and press the knob to switch to the Menu Interface.
  • Start/Stop: Select & press to start/stop. Other options can be switched while running.
  • Operating Time: Max 99 hrs 59 mins 59 secs. Select & press to adjust when flashing.
  • Interval Time: Max 99h59m59s. Select & press to adjust when flashing.
  • Operating Flow Rate: Show flow rate. Adjustable in run/stop mode. Select & press to adjust when flashing.

6.2.3 Allocation Mode (Volume-based Dispensing)

This mode allows you to set the liquid addition volume, interval time, and flow rate for precise dispensing.

Schematic diagram of fluid operation in Volume Allocation Mode, showing liquid addition volume and interval time.

Image: Volume Allocation Mode Fluid Operation Schematic.

  • Dispensing: Select 'Volume Dispensing' (Timed & Quantitative Addition). Select Time/Volume when stopped, then press to switch. No switching during operation.
  • Dispensing Volume: Max 9999.9ml. Select when stopped, press & flash, then rotate to set volume.
  • Start/Stop/Interval Time / Operating Flow Rate: Same as Time-based Dispensing.

6.2.4 Calibration Mode

The Calibration Mode helps reduce addition errors by calibrating the difference between the set volume and the actual dispensed volume.

Icons for Calibration Mode and Power-Off Memory Function.

Image: Calibration Mode icon (left) and Power-Off Memory Function icon (right).

  • Select Calibration: From the menu, select 'Cal' and press the knob to enter the Calibration Menu.
  • Operating Speed Adjustment: Rotate to select, press and wait for flash, then rotate to adjust the value.
  • Operation Countdown: Rotate to select, press to start/stop. The 60s countdown will begin, and the cursor will be fixed.
  • Actual Flow Rate: After the countdown, select, press and wait for flash, then rotate to input the measured value. Press again to finish calibration.

6.3 Parameter Settings

The 'Config' menu allows you to adjust various system parameters.

  • Power-Off Memory Mode: Set whether the pump continues with previous work or resets upon restart.
  • Suck-Back Function: When priming is required in dispensing mode, you can set the suck-back speed and duration. Setting time to 0 disables the function.
  • External Control: The pump supports external control via IO Start/Stop, CW/CCW, RS485, and Analog Signal. (Note: External control features may require customization; contact the manufacturer for details).
Schematic diagram of fluid operation in Suck-Back Function Mode, showing liquid addition time, interval time, and suck-back time.

Image: Suck-Back Function Mode Fluid Operation Schematic.

Circuit board diagram showing connections for IO, CW/CCW, RS485, and Analog Signal for external control.

Image: Control Methods for OEM customization, including IO, RS485, and Analog Signal.

6.4 IO Start/Stop (Optional Foot Switch)

The foot switch provides hands-free operation and can be configured in the Settings Interface for various behaviors.

Image of an optional foot switch with male and female connectors, indicating sizes.

Image: Optional Foot Switch for hands-free operation.

6.4.1 Pull-in / Disconnect

The foot switch acts like a light switch with two stable physical states:

  • Pull-in (Normally Open, NO):
    • Natural State: Pedal not depressed, contacts disconnected, circuit open.
    • Trigger State: Pedal depressed, contacts closed, circuit connected.
    • Mnemonic: Normally Open means open in normal state; connects only when pressed.
  • Disconnect (Normally Closed, NC):
    • Natural State: Pedal not depressed, contacts closed, circuit conducting.
    • Trigger State: Pedal depressed, contacts disconnect, circuit cut off.
    • Mnemonic: Normally Closed means circuit stays on by default; cuts off only when pressed.

6.4.2 Trigger Function

A 'Trigger' refers to a momentary action that changes the switch's state. For a foot switch, a brief 'connection' signal is sent only when the pedal is pressed. Upon release, the switch springs back, and the circuit disconnects.

  • Triggering a Normally Open (NO) switch: Press to change the circuit from “open” to “closed”.
  • Triggering a Normally Closed (NC) switch: Press to change the circuit from “closed” to “open”.

7. Maintenance

7.1 Changing the Pump Tube

Regular inspection and replacement of the pump tube are crucial for maintaining optimal performance and preventing leaks. The spring compensation structure extends the life of the pump pipe and prevents liquid backflow.

  1. Place a flat-head screwdriver into the fixing port and gently pry open the pump cover.
  2. Open the lever and bridge block to release the tube.
  3. Carefully remove the old pump tube.
  4. Insert the new pump tube, ensuring it is correctly seated within the pump head. Close the lever and bridge block, then secure the pump cover.
Four-step visual guide on how to change the pump tube: 1. Pry open cover, 2. Open lever and bridge block, 3. Remove tube, 4. Replace new tube.

Image: Step-by-step instructions for changing the pump tube.

7.2 Pump Tube Life

The service life of the pump tube may vary depending on operating conditions, pipeline pressure, and liquid corrosiveness. The slower the rotational speed of the peristaltic pump, the longer the service life of the pump tube.

  • Norprene tube: ≥1000h (FDA certified, suitable for food/dairy, heat/ozone/acid/alkali resistance, anti-aging, anti-oxidation, long life, working temperature range -59℃ to 135℃).
  • Silicone tube: <200h (Low cost, weak acid/alkali resistance, corrosion resistance to chemicals compared to Norprene).

Pump tube life testing method: ZP600ST intelligent Peristaltic Pump, speed: 400r/min, temperature 20 ℃, Test liquid: water, continuous operation test.

8. Troubleshooting

8.1 Flow Rate Inaccuracy

If you experience discrepancies between the set flow rate and the actual dispensed volume, utilize the Calibration Mode:

  • Enter Calibration Mode from the main menu.
  • Follow the on-screen prompts to measure the actual dispensed volume over a set time.
  • Input the measured value to allow the pump to adjust its internal calculations and reduce future errors.

8.2 System Errors or Unresponsive Behavior

In case of system errors or unexpected behavior, you can perform a factory reset:

  • Navigate to the 'Config' menu.
  • Select 'Restore Factory Settings'.
  • Confirm the reset. This will revert all parameters to their default factory settings.

8.3 Power-Off Data Retention Issues

If the pump does not retain its last operating data after a power cycle, check the Power-Off Memory setting:

  • Go to the 'Config' menu.
  • Ensure the 'Set the power-off restart memory mode' is configured as desired (e.g., 'Continue with previous work').

9. User Tips

  • For highly viscous liquids or applications requiring large torque, it is recommended to reduce the pump speed (below 300R) to prevent blockages and ensure optimal performance.
  • Always ensure the tubing is properly installed and free from kinks or obstructions to maintain consistent flow.
  • Regularly clean the exterior of the pump with a soft, damp cloth. Avoid using harsh chemicals.
  • When not in use for extended periods, disconnect the power adapter and store the pump in a dry, cool place.

10. Warranty and Support

10.1 Certifications

The LEIRONG ZP600ST pump is certified with:

  • CE
  • RoHS
  • ISO9001
Collage of various certificates including CE, RoHS, and ISO9001.

Image: Product certifications.

10.2 Manufacturer Information

LEIRONG Fluid Tech (Shanghai) Co., Ltd. is a high-tech enterprise integrating R&D, production, and sales of precision fluid transmission equipment. They are committed to providing stable and reliable fluid solutions globally.

  • Outstanding R&D: Over 50 patented technologies.
  • Global Certifications: ISO9001, CE, RoHS.
  • Reliable Quality: Products exported to over 80+ countries.
  • Professional Team: 24h/7 service and support.
Icons representing Manufacturer, ISO9001, OEM, Lead Time, Professional, and Service.

Image: LEIRONG's commitment to service and quality.

10.3 Further Assistance

For detailed inquiries, technical support, or customization requests, please refer to the official user manual PDF available at LEIRONG ZP600ST User Manual (PDF) or contact LEIRONG Fluid Tech (Shanghai) Co., Ltd. directly.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.