1. Introduction
Thank you for purchasing the Tahlitech MOT-65 Multi-Function OTDR Tester. This manual provides essential information for the safe and proper use of your device. The MOT-65 is a versatile tool designed for fiber optic and network testing, offering functionalities such as OTDR testing, Visual Fault Locator (VFL), Optical Power Meter (OPM), Stable Laser Source (OLS), UTP cable testing, RJ45 TDR cable testing, digital cable tracing, and various network tests like PING, IP scan, and port flashing.
Please read all instructions carefully before operation and keep this manual for future reference.
2. Safety Information
To ensure safe operation and prevent damage to the device or injury, please observe the following:
- The tester is intended for use in compliance with local electrical regulations. Avoid use in environments unsuitable for electrical devices, such as hospitals or gas stations.
- Use only original accessories to prevent damage.
- Accessories are for the tester's intended use only.
- Protect the product from water splashes or dampness to prevent functional decline or failure. If the tester becomes damp, power it off immediately and disconnect all cables.
- Avoid touching exposed parts of the tester with dust or liquid.
- During transportation and use, avoid violent collisions and vibrations to prevent damage to components.
- Do not leave the tester unattended while charging. If the battery becomes severely hot, power off the tester from the electric source immediately. Do not charge for more than 10 hours.
- Do not connect live cables or devices to the tester's ports when the tester is on.
- Do not use the tester in environments with flammable gas.
- Do not disassemble the instrument. Repairs should only be performed by qualified technicians.
- Avoid using the instrument in environments with strong electromagnetic interference.
- Do not touch the tester with wet hands.
- Clean the tester with a soft, dry cloth. For stubborn dirt, a soft cloth dampened with water or a neutral detergent can be used, ensuring the cloth is sufficiently wrung out.
- Laser Safety Warning: When using OTDR or VFL functions, do not look directly at the laser outlet or through optical instruments. Visible laser light sources can cause damage to the eyes.
3. Setup
3.1. Installing the Battery
The MOT-65 tester has a built-in lithium-ion rechargeable battery. For safety during transportation, the battery cable inside the battery compartment may be disconnected. Before initial use, ensure the battery cables are properly connected.
To power on or off the tester, press and hold the power key continuously. Use the original adapter and cable for charging. The battery charging is complete when the battery icon is full or the charge indicator turns off automatically.

3.2. Device Interface Overview
The MOT-65 features multiple ports and indicators for various functions. All ports are equipped with protective covers.

- Power Button: To turn the device on/off.
- Network Testing Port (LAN/RJ45 TDR): For network cable tests.
- Visual Fault Locator (VFL): For visual fiber fault detection.
- Optical Power Meter (OPM): For optical power measurements.
- OTDR/LS Port: For OTDR testing and Laser Source output.
- LED Lamp: Indicator light.

- Type-C 5V/2A Input: For charging the device.
- Micro SD Card Slot: For external storage.
- UTP/Cable Tracer Port: For UTP cable testing and cable tracing.
- DC5V/2A Power Output: Can be used as a power bank.
- RS 485 Port: For RS485 communication.
4. Operating Instructions
4.1. Optical Time Domain Reflectometer (OTDR)
The OTDR function is used to analyze optical fiber properties, including uniformity, defects, fractures, and joint coupling, by analyzing the measuring curve. It measures fiber attenuation, connector attenuation, and fault locations, providing a loss distribution along the fiber length.
4.1.1. Fiber Connection
Connect the fiber to the top optical interface of the OTDR. The device uses an FC-PC optical connector. Ensure no working light is present in the measured optical fiber to prevent damage to the instrument and inaccurate results.

4.1.2. Auto OTDR Test
By default, the OTDR performs an auto test. Click "OTDR test" or select the desired wavelength, pulse width, and measurement duration in the "Quick Setup" menu to begin testing. The device will automatically analyze linkers/fusion points and generate an event map.

4.1.3. Expert OTDR Test
For more accurate results, manually select parameters such as range, pulse width, and other settings. You can zoom the curve tracer and view detailed event maps. Quick test allows setting laser wavelength, distance range, pulse width, and measurement duration parameters.
Parameter Settings:
- Laser Wavelength: User-selectable (e.g., 1310nm, 1550nm, 1610nm). Up to two wavelengths can be selected for simultaneous measurement. Multi-wavelength measurement is only valid in average mode.
- Distance Scope: Options include "auto", 500m, 1Km, 2Km, 5Km, 10Km, 25Km, 50Km, 100Km, and 200Km. For uncertain lengths, "auto" is recommended. For known lengths, select a range 1.5 times the minimum length.
- Measurement Duration: Options include 5s, 10s, 15s, 30s, 60s, 120s, 180s. Longer durations provide more meticulous and smooth curves.
- Pulse Width: Options include "auto", 5ns, 10ns, 20ns, 30ns, 50ns, 80ns, 160ns, 300ns, 500ns, 800ns, 1000ns, 2000ns, 4000ns, 6000ns, 10000ns, 20000ns.
- Measurement Mode: "Average measurement" and "real-time measurement".
- Refractivity: Default is 1.4685. Do not modify this value unless necessary, as it is crucial for length calculation.
- Unit: "m" (meters) or "ft" (feet).
- Non-reflection Threshold: Input scope: 0.01~2.99, default is auto.
- End Threshold: Used to filter event points. Input scope: 10~30dB, default is 10.00dB.
- Optical Warning of Optical Fiber: "ON" or "OFF". If ON, an alarm will pop up if optical signal is detected.
4.1.4. Event Categories
Events on the optical fiber trace indicate abnormal points that cause loss or sudden changes in reflection power. These include various types of connections, bending, flaws, or fractures. Events are marked with specific symbols on the trace.
- Initial Event: Marks the starting point of the optical fiber, typically the first connector. This is a reflection event.
- End Event: Marks the terminal of the optical fiber, typically the last event. This is also a reflection event.
- Reflection Event: Occurs when optical pulse energy is reflected, such as at a connector. Shown as a peak signal on the trace.
- Non-reflection Event: Indicates loss without light reflection, such as at a fusion point or fiber bending. Shown as a drop in optical power on the curve.
4.1.5. Data Saving and Management
Test reports can be saved in SOR, PDF, or EXCEL formats. Use "Quick Save" for automatic naming or "Save Data" to manually select the path and file name. Default save location is the internal SD card's OTDR directory.
Files can be opened, renamed, copied, deleted, or organized into new folders via the "File Management" menu. The device supports displaying up to 4 traces simultaneously for multi-trace analysis.

4.2. Loss Test
The loss test measures the insertion loss of optical passive devices. Connect short standard jumpers to the OTDR and LS ports. After setting the reference value, connect the optical device to be tested. Click "Start" to begin the test and "Reference" once the power is stable.

4.3. Laser Source (OLS)
The stable laser source provides a stable power output at the same wavelength as the OTDR function. It is useful for engineering and maintenance of optical fiber communication and CATV systems. Wavelengths include 1310nm, 1550nm, and 1610nm. The power can be adjusted from 1-100. Supported modes include CW, 270Hz, 330Hz, 1000Hz, and 2000Hz.

4.4. Optical Power Meter (OPM)
The OPM function supports six wavelengths (1625nm, 1550nm, 1490nm, 1310nm, 1300nm, 850nm) and provides linear or non-linear optical power display. It is used for optical power testing and fiber link loss relative measurement.

4.5. Visual Fault Locator (VFL)
The VFL emits a red laser (650nm) to test multi-mode and single-mode fiber for bending and breakage. It has a test range of up to 8KM. VFL modes include "Steady mode", "Evasive 1Hz", "Evasive 2Hz", and "Time off".

4.6. Digital Cable Tracer
The digital cable tracer is used to search for BNC, network, and telephone cables. Connect the cable to the UTP port or CABLE SCAN (VIDEO OUT) port. Press "Mode" for a few seconds to activate the wire tracer and begin searching.

4.7. UTP Cable Test
Connect a LAN or telephone cable to the UTP port of the tester and the other end to a wire receiver. Use the cable test app to check the cable's continuity and sequence. The display will show the wiring diagram and indicate any breaks or faults.

4.8. RJ45 Cable TDR Test
Connect an RJ45 cable to the LAN port of the tester. Do not connect the other end to any device. Enter the "RJ45 cable TDR test" app to measure the cable's length, pair status (open or short circuit), and detect breakpoints. The maximum measurement length is 600 meters.

4.9. Network Tools
The MOT-65 includes various network testing tools:
- PING Test: Detects if the network is normal by sending ICMP packets.
- IP Scan: Quickly scans IP addresses and detects IP conflicts on a network device.
- LLDP: Detects main capabilities, management IP address, and interface information of network devices.
- Port Flashing: Quickly finds the switch port connected to the device by flashing the port LED.
- DHCP Server, PPPOE, Tracer, Socket Tool, OUI Search, DNS: Additional network diagnostic tools.
5. Maintenance
- Cleaning: Use a soft, dry cloth for cleaning. If dirt is difficult to remove, a soft cloth dampened with water or a neutral detergent can be used, ensuring the cloth is well-wrung.
- Fiber Optic Connectors: Keep fiber connectors and dust caps clean. Clean the detector with special alcohol.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: Avoid overcharging the battery (do not charge for more than 10 hours). If the battery becomes excessively hot during charging, disconnect it immediately.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Low battery or battery cable disconnected. | Charge the device using the original adapter. Check if the battery cable is properly connected inside the compartment. |
| Inaccurate OTDR test results. | Working light in the optical fiber, dirty connectors, or incorrect parameters. | Ensure no working light is present. Clean fiber connectors. Verify OTDR parameters (wavelength, pulse width, etc.). |
| VFL not emitting light. | VFL is off or fiber connection issue. | Check VFL mode settings (Steady, Evasive, Time off). Ensure fiber is correctly connected. |
| Network test (e.g., PING) fails. | Incorrect cable connection or network configuration. | Verify RJ45 cable connection. Check network settings on the device being tested. |
| Device freezes or becomes unresponsive. | Software glitch or temporary error. | Press the reset button (if available) or hold the power button to force a restart. |
7. Specifications
7.1. General Specifications
| Feature | Description |
|---|---|
| Model | MOT-65 |
| Size & Display | 5.4 inch IPS touch screen, 1920x1152 resolution |
| Operating System | Android |
| Power Source | Powered |
| Battery | Built-in 7.4V 5200mAh Li-ion Battery |
| Rechargeable | After charging 2.5 hours, normal working time 11 hours |
| External Power Supply | DC 12V (2A) |
| Power Output | 5V 2A power output (as power bank) |
| Operation Setting | OSD menu, select your desired language: English, Chinese |
| Auto Off | 5-30 (mins) |
| Working Temperature | -10°C ~ +50°C |
| Working Humidity | 30%-90% |
| Dimension/Weight | 264mm x 182mm x 43mm / 1Kg |
| High-concerned chemical | None |
7.2. OTDR Technical Specifications
| Parameter | 1310/1550nm | 1610nm |
|---|---|---|
| Wavelength (nm) Optional | 1310/1550 | 1610 |
| Dynamic range (dB) Optional | 28/26, 30/28, 32/30, 34/32 | 28/30/32/34 |
| Pulse width (ns) | 5,10,20,30,50,80,160,300,500,800,1000,2000,4000,6000,10000,20000 | |
| Testing range | ≤150 Km | |
| Event blind zone (m) | ≤2m | |
| Attenuation blind zone (m) | ≤10m | |
| Linearity (dB/dB) | ±0.05 dB/dB | |
| Loss threshold (dB) | 0.05 | |
| Loss resolution ratio (dB) | 0.01 | |
| Minimum distance resolution | 0.05 | |
| Sampling point(K) | 32-128 | |
| Distance uncertainty (m) | ±(1 m + 5×10-5 x distance + sampling interval) | |
| Distance scope (km) | 0.5,1,2,5,10,25,50,100,200 | |
| Typical real-time refreshing duration | 1s | |
| File format | SOR standard format/PDF/EXCEL | |
| Measurement duration | 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable | |
| Storage | FLASH (EMMC)8G + TF card | |
| Interface type | SC-PC | |
*Note: "*" sign means functions are customizable. The data above is only for reference and any change of them will not be informed in advance. For more detailed technical inquiries, please feel free to contact us.
7.3. Other Function Specifications
| Feature | Description |
|---|---|
| Network Port | 10/100/1000M auto adapt |
| WIFI | Built-in 2.4G WIFI, speeds 150M, display wireless camera image |
| RJ45 cable TDR test | Test cable's length, Max testing up to 600 meter |
| UTP cable test | Test UTP cable connection status and display on the screen. Detect near-end, mid-end and far-end fault point of RJ45 cable connector, also can test shield cable |
| Network test | Trace route, Link monitor, DHCP server, port flashing, Ping test |
| Digital Cable tracer | Search BNC cable, network cable and telephone cable from the mess cables. |
| Electroscope | |
| Voltage range | AC12-1000V |
| Frequency | 50/60Hz |
| Alarm type | Sounds and light double alarms |
| Level | CAT.III 1000V / CAT.IV 600V;CE |
| Visual fault locator | 10mW visual fault locator with 650nm wavelength, emit red laser sources to test multi-mode and single mode fiber's bending and breakage, test range 8KM |
| Optical power meter | Wavelength: 1625,1550nm,1490nm,1310nm,1300nm,850nm, measurement range: -70 ~ +10 dBm, for optical power testing and Fiber link loss relative measurement |
8. User Tips
- For OTDR testing, always ensure the fiber is clean and free of active signals to get accurate readings and prevent damage.
- When using the cable tracer, ensure the remote kit is properly connected for continuity tests.
- Regularly check for software updates to ensure optimal performance and access to new features.
- Utilize the PDF report generation feature for professional documentation of your test results.
- Take advantage of the touch screen and directional keys for efficient navigation through the device's functions.
9. Warranty and Support
Tahlitech provides the following services for the MOT-65 Multi-Function OTDR Tester:
- 12-Month Free Maintenance: Enjoy 12-month free maintenance for any quality problem. The buyer should return products in original conditions and bear shipping cost for return, and pay for any necessary replaced parts.
- Technical Support: If you have any questions or problems while using the Multi-function OTDR tester, or if damages occurred, please contact our technical department.
- Service Label: Keep the S/N label for after-sale service within the warranty period. Products without an S/N label will be charged for repair service.
10. Packing List
- MOT-65 Tester
- Cable Tracer
- Adaptor DC12V 2A / 8GB TF card
- Li-ion Battery (7.4V 5200mAh)
- Tool bag
- DC12V Power cable
- BNC cable
- RS485 cable
- RS485 port
- Audio cable
- Safety cord
- SC connector
- Fiber test head
- BNC alligator clamp
- RJ45 to BNC connector
- OTDR test report
- User manual