1. Product Overview

The Dyness DL5.0C is a high-performance 51.2V 100Ah (5.12 kWh) Lithium Iron Phosphate (LiFePO4) battery module designed for home solar energy storage systems. It features a built-in Smart BMS for comprehensive protection and offers flexible installation options and wide compatibility with various inverters.

Front view of the Dyness DL5.0C battery module
Front view of the Dyness DL5.0C battery module, showing controls and ports.
Dyness DL5.0C battery module with dimensions
Dyness DL5.0C battery module with dimensions: 59cm (W), 54cm (D), 15cm (H).

2. Specifications

Feature Specification
ModelDL5.0C
Battery TypeLiFePO4/Lithium Battery
Nominal Battery Energy5.12 kWh
Nominal Capacity100Ah
Nominal Voltage51.2V
Operating Voltage44.8~57.6V
Recommended C Rate0.5C
Maximum Discharge C Rate1C
Recommended Charge/Discharge Current50A
Max. Power Charge/Discharge Current75A
Peak Power Charge/Discharge Current110A (15s)
Depth of Discharge (DOD)90%
Net Weight54kg
Dimension [W*D*H]558*545*150mm
Charging Temperature Range0~55℃
Discharging Temperature Range-20~55℃
CommunicationCAN/RS485/RS232
Cycle Life≥6000 Cycles
Protection LevelIP20
ExpansionUp to 50 units in parallel
Compatible InvertersSma/Victron/Ingeteam/Delios/Goodwe/Solis/DEYE etc.
Certification & Safety StandardUN38.3/CE-EMC/IEC62619/CE1-021
Warranty10 Years

3. Setup and Installation

The DL5.0C battery offers various installation methods and can be expanded for larger systems. Ensure all connections are secure and follow local electrical codes.

3.1 Installation Methods

The battery supports Flexible Rack, Floor Mounting, Wall-Mount Rack, and 19" Cabinet installations. Refer to the diagram below for visual guidance and compatibility.

Diagram showing various installation methods for Dyness batteries
Diagram illustrating various installation methods: Flexible Rack, Floor Mounting, Wall-Mount Rack, and 19" Cabinet, along with a compatibility table for different models.
  • Flexible Rack: Max 6 pieces in a cluster, flexible design, suitable for DL series.
  • Floor Mounting: Place on a flat surface and fix to the wall, suitable for all series.
  • Wall-Mount Rack: Easy mounting, suitable for all series.
  • 19" Cabinet: Only for DL5.0 or 2*B4850 for a 5kWh solution.

3.2 System Expansion (Systems working less than 1 year)

For systems less than one year old, the DL5.0C can be paralleled with other DL5.0 or DL5.0X units using the same method. A maximum of 5 pieces can be connected in parallel with a DYNESS LV Combiner Box.

Diagram illustrating system storage expansion for systems working less than 1 year
Diagram illustrating system storage expansion for systems working less than 1 year, showing module temperature, parallel connections (max 5 pcs with LV Combiner Box), flexible racks, and daisy-chain communication.

3.3 System Expansion (Systems working more than 1 year)

For older systems, the DYNESS Buddy allows different battery modules or batteries under different conditions to be used in the same system. It supports a maximum 100A input and up to 8 units in parallel.

Diagram illustrating storage system expansion for systems working more than 1 year
Diagram illustrating storage system expansion for systems working more than 1 year, showing the Dyness Buddy, battery extension, and a compatibility matrix for various Dyness battery models with B4850.

3.4 System Combination Options

The DL5.0C can be integrated into various solar energy systems. Below are examples of system combinations with 5kWh batteries using Goodwe and Solis inverters.

Diagram showing system combination options with Goodwe inverters
System combination options with a 5kWh battery using Goodwe inverters, illustrating various solar panel (4kWp, 6kWp, 8kWp, 12kWp) and battery configurations.
Diagram showing system combination options with Solis inverters
System combination options with a 5kWh battery using Solis inverters, illustrating various solar panel (4kWp, 6kWp, 8kWp, 12kWp) and battery configurations.

4. Operating Instructions

The DL5.0C battery is designed for ease of use and monitoring, supporting both inverter-based and independent app monitoring.

4.1 Monitoring Interfaces

You can choose your preferred interface for battery monitoring:

  • Monitoring via Inverter: Connect the battery's BMS communication port to your storage inverter. This allows the inverter to display real-time running data, operation status, and historical data.
  • Independent App (DYNESS APP): Utilize the dedicated DYNESS APP via a Wi-Fi antenna connected to the battery's COM port. The app provides comprehensive monitoring features.
Diagram illustrating preferred interfaces for DL Series battery monitoring
Diagram illustrating preferred interfaces for DL Series battery monitoring, showing monitoring via inverter (BMS Comm) or an independent app (DYNESS APP via Wi-Fi Antenna) with respective data points.

4.2 DYNESS APP Features

The DYNESS APP offers the following functionalities:

  • Battery System Real-time Running Data
  • Battery System Real-time Operation Status
  • Battery System Historical Data
  • Battery Cell Voltage and Balance
  • Battery Cell Temperature
  • Battery System Recycling Status
  • Remote Firmware Updating

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your Dyness DL5.0C battery. Keep the battery clean and ensure proper ventilation.

5.1 Battery Heating for Winter (Optional)

For installations in cold climates, an optional battery heating solution is available to maintain optimal operating temperatures. The heating pad covers both sides of the battery module, ensuring quicker heating and better temperature balance control.

  • Activation Temperature: 2°C inner temperature
  • Max Heating Power: 185W * 4pcs
  • Minimum Working Temperature: -20°C (Ambient Temperature)
  • Heating Pad: PTC (600mm * 600mm each)
Diagram detailing optional battery heating for winter
Diagram detailing optional battery heating for winter, showing heating pads, installation examples in cold environments, and a module temperature graph.

6. Troubleshooting

If you encounter issues with your Dyness DL5.0C battery, consider the following general troubleshooting steps:

  • Check Connections: Ensure all power and communication cables are securely connected.
  • Review App Data: Use the DYNESS APP or your inverter's monitoring interface to check for error codes, abnormal voltages, temperatures, or other diagnostic information.
  • Power Cycle: If the system is unresponsive, try turning off the battery and inverter, waiting a few minutes, and then restarting them.
  • Consult Inverter Manual: For inverter-specific issues, refer to your inverter's instruction manual.
  • Contact Support: If the issue persists, contact Dyness customer support for further assistance.

7. User Tips

Here are some tips to maximize the performance and lifespan of your Dyness DL5.0C battery:

  • Optimal Placement: Install the battery in a location with good ventilation and within its recommended operating temperature range (0~55℃ for charging, -20~55℃ for discharging).
  • Regular Monitoring: Periodically check the battery's status via the DYNESS APP or inverter interface to catch potential issues early.
  • System Compatibility: Ensure your inverter and other system components are compatible with the DL5.0C to avoid performance issues or damage.
  • Firmware Updates: Keep the battery firmware updated through the DYNESS APP to benefit from the latest features and improvements.

8. Warranty and Support

The Dyness DL5.0C Lithium Battery comes with a 10-year warranty, reflecting its high quality and durability. For technical support, inquiries, or warranty claims, please use the contact information below.

8.1 Certifications

The product is certified with:

  • UN38.3
  • CE-EMC
  • IEC62619
  • CE1-021

8.2 Contact Information

For further assistance, please contact:

  • WhatsApp: +86 19176692407
  • Email: 1799483840@qq.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.