Introduction
The ELECTESLA ES-PG300 is a smart LCD digital display pressure gauge designed for accurate measurement of pressure in various mediums including gas, water, oil, and pure liquids. It features a high-quality pressure sensor core, offering high accuracy, corrosion resistance, impact resistance, vibration resistance, and good stability. This manual provides detailed instructions for the safe and efficient use of your ES-PG300 pressure gauge.

Product Features
- High Accuracy: Utilizes a high-quality pressure sensor core for precise measurements.
- Durable Construction: Made with 304 stainless steel for corrosion, impact, and vibration resistance.
- Digital LCD Display: Features a 5-digit LCD display for clear readings.
- Multi-Unit Switching: Easily switch between Mpa, Kpa, Bar, Kgf/cm², and Psi.
- One-Button Zero Calibration: Simple calibration for accurate measurements.
- Low Power Consumption: Operates on 2 AAA batteries for long-term power supply without external power.
- Wide Applicability: Suitable for measuring negative pressure, positive pressure, and differential pressure in various industrial applications.
- Protection Grade: IP65 rated for dust and water resistance.

Specifications
| Feature | Detail |
|---|---|
| Model Number | ES-PG300 |
| Max Measuring Range | -1 to 1000 bar (200 PSI & Above) |
| Dial Diameter | 60mm, 80mm, 100mm (2 - 3.9 Inches) |
| Display Type | DIGITAL (5 digits LCD display) |
| Accuracy | ± 0.4% F.S. |
| Medium Type | Gas, water, oil, pure liquid |
| Pressure Type | Gauge pressure |
| Power Supply | 3V, 2 * AAA batteries (not included) |
| Material | 304 Stainless Steel |
| Pressure Interface | NPT1/2, NPT1/4, G1/2, G1/4, M20*1.5 (external thread, standard) |
| Compensation Temperature | 0 ℃ ~ + 50 ℃ |
| Operating Temperature | - 10 ℃ ~ + 60 ℃ |
| Protection Grade | IP65 |
| Certifications | CE, FCC, RoHS |

Setup
1. Unboxing
Carefully remove the pressure gauge from its packaging. Inspect the device for any signs of damage. The package typically includes the digital pressure gauge unit.
2. Battery Installation
The ES-PG300 requires two AAA batteries (not included). To install:
- Locate the battery compartment, usually on the back or side of the gauge.
- Open the compartment cover.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.

3. Installation and Connection
The pressure gauge features standard external thread connections. Ensure the correct thread size for your application (NPT1/2, NPT1/4, G1/2, G1/4, M20*1.5).
- Identify the appropriate pressure port on your system.
- Carefully thread the pressure gauge into the port. Do not overtighten.
- Ensure a secure, leak-free connection.

Operating Instructions
1. Power On/Off
- Press the ON/OFF button to turn the device on.
- Press and hold the ON/OFF button to turn the device off.
2. Unit Switching
The gauge supports multiple pressure units.
- Short press the UNIT button to cycle through the available units: Mpa, Kpa, Bar, Kgf/cm², Psi.
3. Zero Calibration
To ensure accurate readings, perform a zero calibration before use, especially if the gauge is not reading zero in ambient conditions.
- Ensure the gauge is not connected to any pressure source (i.e., it's at ambient pressure).
- Press the ZERO button to calibrate the display to zero.
4. Reading Pressure
Once powered on and calibrated, the LCD will display the current pressure reading in the selected unit. The gauge can measure gage pressure, absolute pressure, and differential pressure.

Maintenance
1. Cleaning
Wipe the gauge with a soft, dry cloth. Do not use abrasive cleaners or solvents that could damage the display or casing.
2. Battery Replacement
When the battery indicator on the LCD shows low power, replace the two AAA batteries promptly to ensure continuous and accurate operation. Follow the battery installation steps in the Setup section.
3. Storage
Store the pressure gauge in a dry environment within the compensation temperature range of 0 ℃ to +50 ℃. Avoid extreme temperatures and direct sunlight.
Troubleshooting
- No Display: Check if batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
- Inaccurate Readings: Perform a zero calibration. Ensure the gauge is properly connected and there are no leaks in the system. Verify the correct pressure unit is selected.
- Gauge Not Responding: Try removing and reinserting the batteries. If the issue persists, contact customer support.
User Tips
- Always ensure the gauge is at ambient pressure before performing a zero calibration for the most accurate results.
- When connecting the gauge, use appropriate sealing tape or compound on the threads to prevent leaks, but ensure it does not obstruct the pressure sensing element.
- Regularly check the battery indicator to avoid unexpected power loss during critical measurements.
- The IP65 rating means it's protected against dust and low-pressure water jets, but it's not designed for submersion.
Warranty and Support
For any inquiries, technical support, or warranty information, please contact the manufacturer or your point of purchase. You may reach out via:
- Online service
- WhatsApp: +8615665610693
- Email: sales02@jinqu-electric.com