1. Introduction
This manual provides detailed instructions for the KeepLiNK KP-9000-8XTM-X4-AC 8-Port 10G/Multi-Gig L3 Managed Ethernet Switch. It covers product description, packing list, specifications, installation, operation, maintenance, and troubleshooting. The information contained herein is based on the actual product. Any changes to product appearance or packing list will be reflected in official product information.
1.1 Product Overview
The KeepLiNK KP-9000-8XTM-X4-AC is an advanced Layer 3 managed Ethernet switch featuring four (4) 10GbE copper connective ports (RJ45) and four (4) 10GbE fiber SFP+ ports. This switch is designed to expand network capacity, eliminate performance bottlenecks, and support premise expansion needs. It is particularly suitable for small workgroups requiring high-bandwidth for sharing, collaboration, editing, and publishing high-density content such as video or animation. With comprehensive Layer 3 features, it meets current and future demands for virtualization, converged networks, and mobility.
1.2 Key Features
- High-Performance Ports: 8 x 10Gbps total ports, including 4 x 10GBASE-T RJ45 (Copper) and 4 x SFP+ (Fiber).
- Layer 3 Routing: Supports Static Route and RIPv1/v2 for efficient inter-VLAN communication.
- Comprehensive Management: Full L2/L3 features including IPv4/IPv6, VLAN (802.1Q), QoS, ACL, IGMP Snooping, and Link Aggregation (LACP).
- Massive Switching Capacity: 160 Gbps backplane capacity with a forwarding rate of 119 Mpps, ensuring non-blocking performance.
- Enhanced Security: Port Security, 802.1X Network Access Control, and Storm Control to protect your network from threats.
- Flexible Management Options: Manage via Web GUI (Web Interface), CLI (Command Line Interface), or SNMP.
- Quiet & Reliable: Fanless design for near-silent operation, making it suitable for office or home environments.
1.3 Packing List
Please check the contents of your package. If any items are missing or damaged, contact your vendor.
- KeepLiNK 8-Port 10G/Multi-Gig L3 Managed Ethernet Switch
- AC Power Cord (for built-in power supply devices)
- Power Adapter (for non-built-in power devices)
- Hanging Ears, Screws (for rack-mounted devices)
- User Manual
- Certificate of Conformity
2. Specifications
2.1 General Specifications
| Attribute | Value |
|---|---|
| Brand Name | keepLiNK |
| Model Number | KP-9000-8XTM-X4-AC |
| Number of Interfaces | 9 (4x RJ45, 4x SFP+, 1x Console) |
| Number of 100M/1G/2.5G/5G/10G RJ45 Ports | 4 |
| Number of 100M/1G/2.5G/5G/10G SFP+ Ports | 4 |
| Transmission Rate | 10000 Mbps |
| Switch Capacity | 160G |
| Packet Forwarding Rate | 119.04 Mpps |
| Communication Mode | Full-Duplex & Half-Duplex |
| MAC Table Size | 16 K |
| Buffer | 12 Mbit |
| Forwarding Delay | <10 us |
| MDI/MDIX | Yes |
| Jumbo Frame | 10K Bytes |
| VLAN Support | Yes |
| Functions | LACP, QoS, SNMP, VLAN Support |
| Thermal Methods | Silent Fan (Fanless) |
| Installation | Desktop or Wallmount |
| Input Voltage | 100 to 240VAC 50/60Hz |
| Power Wattage | 36W |
| Certification | CE, FCC, RoHS, pse |
| Origin | Mainland China |
2.2 Environmental Limits
| Attribute | Value |
|---|---|
| Operating Temperature | -10℃ to 55℃ |
| Storage Temperature | -40℃ to 70℃ |
| Relative Humidity | 10%~90% (non-condensing) |
| MTBF | 100,000H |
2.3 Physical Characteristics
| Attribute | Value |
|---|---|
| Dimensions (L x W x H) | 270 x 181 x 44 mm (10.63 x 7.13 x 1.73 in) |
| Weight | 1.42 kg (3.13 lbs) |
2.4 Standards and Certifications
- IEC 61000-4-4 EFT/Burst: Power 4 kV; Signal 2 kV
- IEC 61000-4-5 Surge Protection: Power 6 kV; Signal 2 kV
- IEC 61000-4-2 ESD: Contact 8KV, Air 15KV
- IEC 60068-2-31: 0.5m Free fall

Image: Environmental Limits, Physical Characteristics, Standards and Certifications, and Included Items.
3. Setup and Installation
3.1 Precautions for Device Connection and Installation
- Network Cable:
- For 100Mbps RJ45 interfaces, use Cat5 or above Ethernet cable.
- For 1000Mbps/2.5GE/5GE RJ45 interfaces, use Cat5e or above Ethernet cables.
- For 10GE speed RJ45 interfaces, use Cat6a or above Ethernet cables.
- Fiber Optic Cable:
- Fiber optics and connectors must be used in conjunction with optical modules.
- The bending radius of the optical fiber should not be less than 40mm.
3.2 Safety Precautions for Equipment Installation
- Always ensure the power is OFF during installation.
- The switch requires the correct power supply. Verify that the power supply voltage matches the voltage indicated on the switch.
- Before powering on, ensure the power circuit is not overloaded to prevent operational issues or losses.
- To avoid electric shock, do not open the switch casing while it is in operation, even if it appears off. Do not open it yourself.
3.3 Installation Environment Precautions
To ensure long-term stable operation and extend service life, maintain appropriate temperature and humidity. Extreme conditions can cause insulation material leakage, deformation, and metal corrosion.
- Static Electricity: To prevent static electricity from affecting operation, regularly dust the device, maintain clean indoor air, ensure good grounding, and facilitate smooth transfer of static electricity.
- Electromagnetic Interference: Electromagnetic interference can affect electronic components. To minimize adverse effects, ensure the power supply system has anti-grid interference measures, and keep switches away from high-frequency, high-power, and high-current equipment.
- Lightning Protection: Strong currents from lightning strikes can fatally damage electronic devices. For better protection, ensure the rack, power sockets, and ground are in good contact. Use reasonable wiring to avoid internal induced lightning. For outdoor wiring, signal lightning protectors are recommended.
3.4 Switch Installation Methods
The switch supports desktop, wall-mounted, and rack-mounted installations. Choose the method suitable for your environment.
3.4.1 Rack-Mounted Installation
- Prepare the provided screws and hanging ears. Secure the hanging ears to both ends of the device.
- Carefully slide the device parallel to the tray into the cabinet and secure it with cabinet screws.

Image: Front view of the KeepLiNK switch showing ports and LED indicators.

Image: KeepLiNK 10G/Multi-Gig 8 Ports Managed Layer 3 Switch, front view with port details.
3.4.2 Desktop Installation
Place the switch on a flat and secure desktop. Ensure adequate ventilation and heat dissipation space. Do not place heavy objects on the switch.
3.4.3 Wall-Mounting Installation
- Mark and punch holes on the wall according to the switch's mounting holes. Ensure a distance of 3mm ± 0.5mm between the nuts and the wall.
- Insert embedded nails (e.g., wall anchors) into the punched holes.
- Align the wall mounting holes on the device with the screws for installation and fixation.

Image: Wall-mounting installation steps including punching holes, embedding nails, and securing the device.
4. Operation
4.1 Product Indicator Lights (LEDs)
The switch features various LED indicators to provide real-time status information. Refer to the table below for their definitions:
| Sign | Definition | Status | Description |
|---|---|---|---|
| PWR/P | Power indicator light | Green light always on/off | Power is connected/not connected |
| AI PoE | AI light | Green light on/off | AI PoE started/not started |
| SYS/NMS/S/N | System light | Green light on/off | System working/system not started |
| 100Mbps copper port Connection status indicator light | Left light (Speed) | Yellow light always on | 100M speed |
| Yellow light off | 10M speed | ||
| Right light (Link/act) | Green light always on | Port connected | |
| Green light off | Port not connected | ||
| Green light blink | The port is connected and there is data transmission and reception | ||
| 1000Mbps copper port Connection status indicator light | Left light (Speed) | Yellow light always on | 1000M speed |
| Yellow light off | 10/100M speed | ||
| Right light (Link/act) | Green light always on | Port connected | |
| Green light off | Port not connected | ||
| Green light blink | The port is connected and there is data transmission and reception | ||
| 2.5G copper port Connection status indicator light | Left light (Speed) | Yellow light on | 2.5G speed |
| Yellow light off or green light always on | 10/100/1000M speed | ||
| Right light (Link/act) | Green light always on | Port connected or 10/100/1000M speed | |
| Green light off | Port not connected | ||
| Light blink | The port is connected and there is data transmission and reception | ||
| 10G copper port Connection status indicator light | Left light (Speed) | Yellow light on | 10G speed |
| Green light on | 5G speed | ||
| Light blink | Data transmission and reception | ||
| Right light (Speed) | Yellow light on | 2.5G rate | |
| Green light on | 1G rate | ||
| Light off | Port not connected | ||
| Light blink | The port is connected and there is data transmission and reception | ||
| 10G downlink fiber port Connection status indicator light | Link/act | Yellow light always on | 10G speed |
| Green light always on | 1G rate | ||
| Light off | Port not connected | ||
| Optical port connection status indicator light | Link/act | Green light on | Port connected |
| Green light off | Port not connected |
4.2 DIP Switch Instructions
The switch features DIP switches for various configurations. The specific definitions depend on whether it's a Non-PoE or PoE switch, and the number of DIP switches.
4.2.1 DIP Switch Definition for Non-PoE Switch
| DIP switch specification | Sequence | Definition of DIP switch | Description |
|---|---|---|---|
| 4 DIP Switch | 1 | Reserve | Reserve |
| 2 | Extend | 250m long distance transmission (downlink port) | |
| 3 | Port Isolation | Port isolation | |
| 4 | Storm Control | Suppress broadcast data |
4.2.2 DIP Switch Definition for PoE Switch
| DIP switch specification | Sequence | Definition of DIP switch | Description |
|---|---|---|---|
| 4 DIP Switch | 1 | AI PoE | Auto detect and reboot unresponsive PoE devices for recovery |
| 2 | Extend | 250m long distance transmission (PoE port) | |
| 3 | Port Isolation | Port isolation | |
| 4 | Storm Control | Suppress broadcast data | |
| 3 DIP Switch | 1 | Extend | 250m long distance transmission (PoE port) |
| 2 | Standard | Normal mode | |
| 3 | Port Isolation | Port isolation | |
| 2 DIP Switch | 1 | Extend | 250m long distance transmission (PoE port) |
| 2 | AI PoE/Reserve | AI PoE/Reserve |
4.2.3 DIP Switch Definition for Lite Management Switches
| DIP switch specification | Sequence | Definition of DIP switch | Description |
|---|---|---|---|
| 3 DIP Switch | 1 | Web-managed | WEB management |
| 2 | Standard | Standard mode | |
| 3 | Port Control | Port isolation |
Note: The specific DIP switch definition shall be based on the actual product.
4.3 Web-Based Management
This content is applicable to network management products. For first-time use:
- Connect the device to a PC and ensure the device initialization is complete.
- Configure the IP address of the PC and the default IP address of the switch to be in the same network segment.
- Open a web browser on your PC and input
http://192.168.1.168. Press "Enter" to access the network management login interface. - Enter the default username "admin" and password "admin" to log in.

Image: Web-Based Management login interface.

Image: Detailed view of the Web-Based Management login screen.
4.4 Console Port Management
- Use a console port cable to connect the console port of your PC to the switch.
- Open terminal simulation software (e.g., PuTTY, Tera Term) on your PC.
- Establish a connection, select the serial port corresponding to your console cable, and configure the communication parameters as follows:
- Transmission rate: 115200
- Data bits: 8
- Check digit: None
- Stop bits: 1
- Flow control method: None
4.5 PoE Powered Function (If applicable)
This feature is applicable to PoE switches only. Standard PoE power supply includes protocol detection, power pin sequence detection, power output, anomaly protection, and link anomaly monitoring. The PoE power supply protocols supported are IEEE802.3af (15.4W), IEEE802.3at (30W), and IEEE802.3bt (90W).
The standard PoE power supply pin sequence is 1,2+/3,6-, and the standard PoE++ power supply pin sequence is 1,2,4,5+/3,6,7,8-.
Standard PoE switches automatically detect and provide power to standard PoE devices. Non-PoE devices will not be powered on and will only transmit data.

Image: Illustration of PoE power supply to equipment.
5. Maintenance
Proper maintenance ensures the longevity and optimal performance of your KeepLiNK switch. Adhere to the environmental precautions outlined in Section 3.3.
5.1 Environmental Considerations
- Maintain operating temperature between -10℃ and 55℃.
- Maintain relative humidity between 10% and 90% (non-condensing).
- Regularly clean the device to prevent dust accumulation, which can affect cooling and lead to static electricity issues.
- Ensure proper grounding to dissipate static electricity and protect against electrical surges.
5.2 Software and Firmware Updates
Periodically check the manufacturer's website for firmware updates. Keeping the device's firmware up-to-date can improve performance, add new features, and address security vulnerabilities.
- Upgrade Firmware: Firmware can be upgraded via the Web Management interface or CLI. Refer to the specific firmware upgrade guide for detailed steps.
- System Log: Utilize the system log feature (accessible via Web GUI or CLI) to monitor device status and troubleshoot issues.
6. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, consult the full user manual or contact technical support.
6.1 No Power / Device Not Turning On
- Check if the power cord is securely connected to both the switch and the power outlet.
- Verify that the power outlet is functional by plugging in another device.
- Ensure the power supply voltage matches the switch's requirements (100-240VAC).
- Check the PWR/P LED indicator. If it's off, there's no power.
6.2 No Network Connectivity
- Verify that Ethernet cables are correctly connected to the switch ports and client devices.
- Check the Link/Act LEDs for the connected ports. A solid green light indicates a link, and blinking indicates data activity. If the LED is off, check the cable and the connected device.
- Ensure you are using the correct cable type (e.g., Cat6a for 10GE connections).
- If using SFP+ ports, ensure compatible SFP+ modules and fiber optic cables are used.
- Check the DIP switch settings. Incorrect settings (e.g., Port Isolation, Extend mode) can affect connectivity.
- If managing the switch via Web GUI, ensure your PC's IP address is in the same network segment as the switch's default IP.
6.3 Slow Network Performance
- Check the speed LEDs for the connected ports to confirm they are operating at the expected speed (e.g., Yellow for 10G, Green for 5G).
- Ensure all connected devices and cables support the desired speeds (e.g., 10Gbps).
- Check for network loops or broadcast storms. The Storm Control DIP switch setting can help mitigate broadcast storms.
- Review QoS settings via the Web GUI to ensure critical applications are prioritized correctly.
7. User Tips
- Leverage Layer 3 Features: For advanced network segmentation and efficient inter-VLAN routing, configure Static Route and RIPv1/v2 via the Web GUI.
- Optimize for High Bandwidth: When connecting devices requiring 10Gbps, ensure both the network adapter and the Ethernet cable (Cat6a or higher) are rated for 10G to achieve optimal performance.
- Silent Operation: The fanless design makes this switch ideal for noise-sensitive environments like home offices or studios. Ensure adequate airflow around the unit to maintain passive cooling efficiency.
- Cable Management: Proper cable management not only improves aesthetics but also helps maintain good airflow and prevents accidental disconnections.
- Regular Monitoring: Utilize the Web-Based Management interface to regularly monitor port status, traffic, and system logs for proactive network health management.
8. Warranty and Support
8.1 After-sales Service Letter of Commitment
Within seven days from the date of sale, if the entire device fails, you may choose to repair, replace, or return it. If a performance failure occurs within seven days to one year from the date of sale (based on the purchase invoice and proof of three guarantees), the entire machine can be repaired or replaced.
Beyond the one-year hardware warranty period, the cost of replacing hardware will be borne by the user. No additional costs will be added by the company.
8.2 Other Service Commitments
The manufacturer provides 7 x 24 hour after-sales support services.
8.3 Circumstances Without Warranty Coverage
Failure or damage of equipment (including parts) under the following circumstances are not covered by warranty:
- Accessories supplied by other companies (e.g., power supply, adapter) are guaranteed by their respective manufacturers.
- The entire machine and parts have exceeded their warranty period.
- Equipment failure or damage caused by unauthorized repair, alteration, or demolition by personnel not affiliated with the company.
- Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, and inputting incorrect voltage.
- Failure or damage caused by the use of non-genuine or unpublished software.
- Failures or losses caused by natural disasters (e.g., earthquakes, fires).
8.4 Warranty Card
A warranty card is included with your product. Please fill it out and retain it for warranty claims. It typically includes fields for User name, User address, Post code, Contact address, Contact person, Tel, E-mail, Product model number, Serial number, and Date of purchase.
8.5 Additional Resources
For a complete and detailed user manual, you can refer to the official PDF document: KeepLiNK Ethernet Switch User Manual (PDF).
9. Frequently Asked Questions (FAQ)
Q: What is the default IP address for Web Management?
A: The default IP address for Web Management is 192.168.1.168. Ensure your PC's IP address is in the same subnet to access it.
Q: What are the default login credentials for the Web GUI?
A: The default username is "admin" and the default password is "admin". It is recommended to change these after initial setup for security.
Q: Can I use this switch in a home environment?
A: Yes, its fanless design ensures quiet operation, making it suitable for both office and home environments where noise levels are a concern.
Q: What kind of cables should I use for 10Gbps connections?
A: For RJ45 ports, use Cat6a or higher Ethernet cables. For SFP+ ports, use compatible SFP+ modules and fiber optic cables.