1. Introduction
The JIKONG JK-PB1A16S15P V19 is an advanced Battery Management System (BMS) designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge and over-temperature protection, a coulomb meter, Bluetooth communication, and host computer monitoring capabilities. This BMS is suitable for LiFePo4, Li-Ion, and LTO battery types, making it ideal for household energy storage, communication base stations, building energy storage, and industrial equipment backup power applications.

The protection board utilizes energy transfer active balancing technology, ensuring maximum battery consistency and extending battery life. It supports mobile APP (Android and iOS) and PC software for monitoring battery status, modifying parameters, and controlling charge/discharge switches. Its compact size, simple operation, and comprehensive functions make it a versatile solution for various battery PACK applications.

2. Product Overview
2.1. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- Supports PC operations
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 communication
- Support CAN communication
- Support heating function
- Alarm dry contact function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
- Battery parallel current limiting function
2.2. Structural Block Diagram
The following diagram illustrates the internal structure and main components of the JIKONG BMS.

2.3. Precision Aesthetics and Performance
Every part of the BMS is carefully crafted for peak performance and reliability.


3. Specifications
The JIKONG BMS offers robust performance and protection features. Key specifications are detailed below:

| Feature | Specification |
|---|---|
| Brand Name | JIKONG |
| Type | LIFEPO4 Battery BMS (also supports Li-Ion, LTO) |
| Usage Scenario | Energy Storage BMS |
| Battery Strings Supported | 8S-16S |
| Balance Function | Active Balanced BMS |
| Balancing Current | 1A |
| Charging Current (Continuous) | 150A |
| Discharge Current (Continuous) | 150A |
| Maximum Discharge Current | 300A |
| Charge and Discharge Port | Common Port BMS |
| Protective Plate Size | 300*100*24mm |
| Supply Voltage | 20-70V |
| Operating Temperature | -30 to 70°C |
| Voltage Acquisition Accuracy | ±3mV |
| Temperature Detection Quantity | 4 |
| Certification | CE, FCC, RoHS |
| Function | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection |

4. Package Contents
Upon opening the package, verify that all the following items are included:

- Packing BOX
- BMS (Main Board)
- Interface Board
- Adapter
- RJ45 Network Cable (400mm)
- Switch (500mm)
- Heating Adapter Cable x1 (170mm)
- Cells Total B+ Cable x1 (500mm)
- Sampling Line A (900mm)
- Sampling Line B (300mm)
- Sampling Line C (300mm)
- Adapter Cable A (300mm)
- Adapter Cable B (300mm)
- Adapter Cable C (300mm)
- 4.3LCD-TTL-P (Optional, if purchased with LCD version)
5. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your JIKONG BMS. Please follow these instructions carefully.
5.1. Device Activation
Before powering on the protection board, ensure all balance cables are correctly connected and the P- and B- terminals are securely connected. Confirm that the protection board is firmly fixed to the battery cells. Incorrect connections can lead to malfunctions or damage.
The BMS does not have a power-on switch. It activates when a charger (with voltage 2V higher than battery voltage) is connected after battery assembly. Alternatively, if a display screen and button are used, simply insert the cable into the display interface and press the button to activate.
5.2. Wiring Diagrams
The JIKONG BMS is compatible with 7-16 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Below are examples for 16-string and 8-string configurations.

General Wiring Notes:
- Connect the balance cables (sampling lines) to the corresponding battery cells, ensuring correct polarity and sequence.
- Connect the main power cables (B- and P+) to the battery pack and load/charger respectively.
- Ensure all connections are tight and secure to prevent loose contacts and potential hazards.
- Refer to the detailed pin definitions in the full PDF manual for specific connector layouts.
5.3. Interface Board Connections
The interface board provides various ports for communication, display, and control. Familiarize yourself with the layout and connections.

Key Interface Ports:
- RS485-1 Interface (8P8C RJ45 Socket): For communication with inverters and other settings.
- RS485-2 Interface (8P8C RJ45 Socket): For connecting multiple BMS units in parallel and communicating with a host computer.
- RS232 Interface (6P6C RJ11 Socket): For serial communication.
- CAN Interface: For CAN bus communication.
- Dry Interface: For controlling external devices like alarms or fans.
- Dial Switch: Used to set the communication address for parallel operation.
- P1, P2, P3 Ports: Connect to the main BMS board.
- UART Port: For display or switch connections.
- Heat Function Port: For connecting heating elements.

5.4. APP Installation
The mobile APP allows for convenient monitoring and control of the BMS. To install the APP, scan the QR code below. An Android device running Android 7 or higher is required.

6. Operation
The JIKONG BMS offers various functions for managing your battery system. These can be controlled via the mobile APP or PC software.
6.1. Active Equalization
The BMS uses active equalization to balance cell voltages. Energy is transferred from higher-voltage cells to lower-voltage cells. Before using, set basic battery parameters (number of cells, capacity, trigger differential pressure, voltage/current calibration) in the APP. The default balance current is 1A/2A, adjustable based on battery capacity (recommended not to exceed 0.2C). Equalization automatically activates when the voltage difference between any two strings exceeds the set value and turns off when below it. The balancing function can be disabled via the BMS control page in the APP if not needed.

6.2. Heating Function
The BMS includes a heating function to prevent battery activity reduction in low temperatures. It uses a resistance heater or heating film (not included) with a designed current of 10A. This function can be switched on/off via the APP. It is recommended to install a normally closed temperature switch (45-65°C) in series with the heating circuit as a secondary protection to prevent overheating.
6.3. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects overtemperature, overcharge, or overdischarge, the alarm interface can switch the dry contact status to trigger a buzzer or activate a fan. Users can select two trigger conditions based on their needs. The control principle involves the dry contact switching to drive external alarm equipment.
6.4. Communication Function
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate inverter communication protocol via the APP. Two RS485 interfaces are available: RS485-1 for inverter communication and RS485-2 for parallel connection of multiple BMS units and communication with a host computer. The default baud rate is 115200. Communication addresses (0-15) can be set using DIP switches for multi-BMS setups.
6.5. Charge Current Limiting Function
This function limits the charging current to approximately 10A when an overcurrent condition is detected during charging, protecting the battery. Users can set continuous charging current, overcurrent delay, and release time via the APP based on battery capacity and charger output.
6.6. APP and PC Software Usage
Monitor and control your BMS using the dedicated mobile APP or PC software. The video below demonstrates the unboxing, product features, and interaction with the APP and PC software, including inverter settings.
The mobile APP provides real-time data such as cell voltage, current, temperature, SOC, and cycle count. It also allows selection of various inverter communication protocols.


The PC software offers a comprehensive interface for monitoring and setting parameters, including real-time status, parameter settings, BMS control, system logs, and detailed logs.



6.7. Parallel Function
The parallel function allows simultaneous monitoring of multiple BMS units by a host computer via RS485. Up to 16 BMS units are supported. Each BMS must be assigned a unique address (0-15) using the DIP switches. Address 0 is designated as the host, and addresses 1-15 are slaves. The host computer connects to the host BMS via a USB to RS485 serial port cable, and slave BMS units are daisy-chained using RJ45 Ethernet cables.
Refer to the full PDF manual for detailed instructions on setting DIP switches for each address (pages 33-34). The DIP switch settings determine the address of each BMS unit in a parallel configuration. For example, for Host Address 0, all four DIP switches are typically OFF. For Slave Address 1, the first DIP switch is ON and the rest are OFF. For Slave Address 2, the second DIP switch is ON and the rest are OFF, and so on. This allows the host computer to poll data from all connected BMS units.
7. Maintenance and Protection Features
The JIKONG BMS is equipped with multiple protection features to ensure the longevity and safety of your battery pack. Regular monitoring via the APP or PC software is recommended.
- Overcharge Protection and Recovery: Prevents battery overcharging by shutting off charging when any cell exceeds the set overcharge voltage. Charging resumes when all cells fall below the recovery voltage.
- Discharge Undervoltage Protection and Recovery: Protects cells from over-discharge by cutting off discharge when any cell drops below the undervoltage protection threshold. Discharge resumes when cells are charged above the recovery voltage. An automatic shutdown voltage is also set for critical low voltage.
- Charge Overcurrent Protection and Recovery: Prevents damage from excessive charging current. If the charging current exceeds the set continuous limit for a specified delay, charging is stopped. It resumes after a set recovery time.
- Discharge Overcurrent Protection and Recovery: Similar to charge overcurrent, this protects against excessive discharge current. Discharge is stopped if the current exceeds the limit for a set delay and resumes after a recovery time.
- Overtemperature Protection and Recovery: Monitors battery temperature and stops charging/discharging if temperatures exceed set limits. Operations resume once temperatures return to safe levels.
- Low Temperature Protection and Recovery (Charging): Stops charging if battery temperature drops below a set low limit to prevent damage. Charging resumes when the temperature rises above the recovery threshold. For extremely cold environments, using the heating function is recommended.
- Short Circuit Protection and Recovery: Detects short circuits and immediately stops current flow. The protection board will resume operation after a set recovery time. Users can adjust the short circuit delay and recovery time via the APP if needed, especially during initial connection of chargers or loads with high peak currents.
- Emergency Switch: In case of critical issues like over-temperature, over-discharge, over-charge, or cell drop, activating the emergency switch via the APP will enable charge and discharge for 30 minutes, providing a temporary operational window.
- Intelligent Sleep: This feature allows the BMS to enter a low-power sleep mode if the charge/discharge current is below 1A for 26 consecutive hours, reducing self-consumption. It can be reactivated by pressing a button or connecting a charger.

8. Troubleshooting
This section provides guidance on common issues indicated by the BMS LED lights.
| Status | Normal, Alarm, or Protection | ON/OFF Indicator | RUN | ALM | L1-L6 | Instructions |
|---|---|---|---|---|---|---|
| Power Off | Normal | OFF | ||||
| Balance | Normal | ON | Flicker | OFF | Battery based display | |
| Charging | Normal | ON | Flicker | OFF | Battery based display | |
| Charging | Overcurrent, Overtemperature, Overvoltage, Charging Failure | ON | Flicker | Flicker | Battery based display | |
| Discharge | Normal | ON | Flicker | OFF | Battery based display | |
| Discharge | Overcurrent, Overtemperature, Undervoltage, Discharge Failure | ON | Flicker | Flicker | Battery based display | |
| Other Alarm | Password not changed, Short circuit, Temperature | ON | Flicker | Flicker | Battery based display |
Note: When the device address is set to 0 (host), the last LED indicator L6 blinks. If the address is set to other values (slave), the LED is off and blinks after successful communication with the host. ON indicates the LED is on, OFF indicates it is off.
9. User Tips
- Always double-check all wiring connections, especially polarity, before powering on the BMS to prevent damage.
- Utilize the mobile APP or PC software for real-time monitoring of battery parameters to ensure optimal performance and detect potential issues early.
- For multi-BMS setups, carefully configure the DIP switches for each unit's address to ensure proper communication and parallel operation.
- If experiencing issues with charging or discharging, consult the LED indicators and the troubleshooting table for initial diagnosis.
- In cold environments, consider using the heating function to maintain battery performance and prevent low-temperature related issues.
10. Warranty and Support
For detailed technical support, warranty information, and further operational guidelines, please refer to the complete user manual PDF. The PDF manual provides in-depth explanations and diagrams for advanced configurations and troubleshooting.
You can access the full user manual PDF here: JIKONG BMS User Manual (PDF)