1. Introduction

The TOOLTOP ET11S Pro is a high-precision, two-in-one handheld instrument combining a thermal imaging camera with a True RMS multimeter. It is designed for electricians and maintenance technicians to quickly identify problems in various scenarios, including circuit board maintenance, power maintenance, distribution cabinet inspection, and underfloor heating water pipe inspection. This manual provides essential information for the safe and effective use of your device.

TOOLTOP ET11S Pro Dual Light Fusion Thermal Imaging Multimeter with 2.8-inch LCD screen, 19999 count, and -20~550°C temperature range.
Figure 1: TOOLTOP ET11S Pro Dual Light Fusion Thermal Imaging Multimeter

2. Safety Information

Please read and understand all safety warnings and operating instructions before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always use the device within its specified voltage and current limits.
  • Do not use the device if it appears damaged or if the test leads are compromised.
  • Ensure proper connection of test leads before taking measurements.
  • Avoid contact with live circuits when replacing the battery or fuses.
  • Use caution when working with high voltages.
  • Keep the device dry and clean.
  • Do not attempt to repair or modify the device yourself. Refer to qualified service personnel.

3. Package Contents

Verify that all items are present and undamaged upon unpacking:

  • 1 x Thermal Camera Multimeter (ET11S Pro)
  • 1 x USB Cable
  • 1 x English Manual
  • 1 x Storage Bag
  • 1 x Multimeter probe (Universal probe)
Image showing the standard accessories: data line, universal probe, instructions manual, and storage bag.
Figure 2: Standard Accessories

4. Product Overview

The ET11S Pro features a 2.8-inch IPS LCD screen and intuitive button layout for both thermal imaging and multimeter functions.

Diagram illustrating the function buttons for both thermal imaging and multimeter interfaces, including power button, mode switch, data hold, save, USB Type-C port, and probe inputs.
Figure 3: Introduction to Function Buttons

4.1 Thermal Imaging Interface Buttons

  • Press and hold for 3 seconds: Turn on the key.
  • Short press: Switch the function of the multimeter.
  • Long press: Set menu.
  • Short press: Multifunctional.
  • Long press: Dual light fusion ratio switching.
  • Short press: Switch multimeter gear.
  • Long press: Switch color palette.
  • USB TYPE-C: Charging and data transfer port.
  • Short press: Multimeter data retention.
  • Long press: Screen capture/saving.
  • Short press: Manual range.
  • Long press: REL relative value.
  • AC or DC Current measuring port: Input for current measurements.
  • COM public measurement input port: Common input for measurements.
  • VΩ-Hz measurement port: Input for voltage, resistance, diode, temperature, capacitance, frequency measurements.

4.2 Multimeter Interface Buttons

  • Press and hold for 3 seconds: Turn on the key.
  • Short press: Thermal imaging function switch.
  • Long press: Set menu.
  • Short press: Multifunctional.
  • Short press: Switch multimeter gear.
  • USB TYPE-C: Charging and data transfer port.
  • Short press: Data retention.
  • Long press: Save measurement waveform data.
  • Short press: Manual range.
  • Long press: REL relative value.
  • AC or DC Current measuring port: Input for current measurements.
  • COM public measurement input port: Common input for measurements.
  • VΩ-Hz measurement port: Input for voltage, resistance, diode, temperature, capacitance, frequency measurements.

5. Setup

5.1 Battery Installation and Charging

The ET11S Pro comes with a built-in detachable 18650 lithium battery. Ensure the battery is properly installed before first use. Charge the device using the provided USB Type-C cable.

  • Locate the battery compartment on the device.
  • Insert the 18650 lithium battery, ensuring correct polarity.
  • Close the battery compartment securely.
  • Connect the USB Type-C cable to the device and a suitable USB power source for charging.
  • A full charge provides approximately 8 hours of continuous operation.
Image showing the Type-C charging port and the detachable 18650 lithium battery compartment.
Figure 4: Type-C Charging and Battery

5.2 Initial Power On

Press and hold the power button (usually the top-left button on the device) for 3 seconds to turn on the device. The device will boot into its default mode.

6. Operating Instructions

6.1 Multimeter Function

The multimeter offers a wide range of measurement functions, including AC/DC voltage, AC/DC current, resistance, capacitance, diode, buzzer, and duty cycle. It features a 19999 count True RMS display.

  • Connecting Probes: Insert the universal probes into the appropriate input ports (COM and VΩ-Hz or AC/DC Current).
  • Selecting Measurement Mode: Use the 'Short press: Switch multimeter gear' button to cycle through different measurement functions (e.g., V, A, Ω, F, Hz).
  • Automatic Range: The multimeter defaults to automatic range measurement. For manual range, short press the 'Manual range' button.
  • Data Hold: Short press the 'Data retention' button to hold the current reading on the display.
  • LIVE Mode (Frontline Live Identification): In multimeter mode, switch to LIVE mode to distinguish between neutral and live wires. This function provides sensitive sensing with an interface prompt accompanied by a buzzing sound to help identify live wires and avoid electric shock.
Image showing the multimeter function in use, measuring an electrical panel with probes connected.
Figure 5: Multimeter Function in Use
Image demonstrating the LIVE mode for identifying live wires in an electrical outlet, showing 'LIVE' on the display.
Figure 6: Frontline Live Identification Measurement (LIVE Mode)

6.2 Thermal Imaging Function

The thermal imaging camera features a 32x32 infrared resolution and a 240x240 visible light resolution, with a temperature range of -20°C to +550°C.

  • Switching to Thermal Imaging: In multimeter mode, short press the 'Thermal imaging function switch' button to activate the thermal camera.
  • Temperature Tracking: The device automatically tracks the highest temperature point, lowest temperature point, and a center point.
  • Over-temperature Alarm: An alarm will activate if the measured temperature exceeds a set threshold.
  • Color Palettes: Long press the 'Switch color palette' button to choose from 5 color palette modes: Iron Red, Rainbow, Fusion, White Heat, and Red Heat.
  • Dual Light Fusion: The device supports dual light fusion, combining visible light and infrared images for enhanced detail. Long press the 'Dual light fusion ratio switching' button to adjust the fusion ratio.
Thermal image of a hand showing automatic tracking of minimum, highest, and center temperature points.
Figure 7: Automatic High and Low Temperature Capture
Three images demonstrating different thermal imaging modes: Thermal imaging mode, Dual light fusion mode, and Visible light mode.
Figure 8: Thermal Imaging Modes

6.3 Data Transfer and Analysis

The ET11S Pro supports PC software for USB transfer and analysis of thermal images and measurement data.

  • Connect the device to a computer using the provided USB Type-C cable.
  • The device will enter USB mode, allowing for quick viewing of stored images and data reproduction.
  • Refer to the PC software manual (if provided separately) for detailed instructions on data analysis.
Image showing the ET11S Pro connected to a laptop via USB, displaying thermal images and data on the computer screen.
Figure 9: Data Transfer to Computer

7. Maintenance

  • Cleaning: Use a soft, damp cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in its provided storage bag in a cool, dry place when not in use.
  • Battery Care: For long-term storage, charge the battery to approximately 50% and recharge every few months to maintain battery health.
  • Calibration: Regular calibration by qualified personnel is recommended to ensure accuracy, especially for professional use.

8. Troubleshooting

If you encounter issues with your TOOLTOP ET11S Pro, please refer to the following common troubleshooting steps:

  • Device not powering on: Ensure the battery is charged and correctly installed. Try charging the device for at least 30 minutes.
  • Inaccurate readings: Check that the test leads are properly connected and undamaged. Ensure the correct measurement mode is selected. For thermal imaging, verify the emissivity setting is appropriate for the target material.
  • Display issues: If the screen is unresponsive or shows abnormal patterns, try restarting the device.
  • Connectivity problems (USB): Ensure the USB cable is securely connected to both the device and the computer. Try a different USB port or cable.

If the problem persists, contact customer support for further assistance.

9. Specifications

Parameter Category Specification
General
Brand Name easyover (TOOLTOP)
Model ET11S Pro
Style Handheld
Display Size 2.8 Inches (IPS LCD)
Power Type Charger (USB Type-C)
Battery Included Yes (Detachable 18650 Lithium Battery)
Is Smart Device No
Certification CE, RoHS
Thermal Imaging Parameters
Infrared Resolution 32x32 pixels
Thermal Imaging Display Resolution 240x240 pixels
Field of View (FOV) 33°(H) x 33°(V)
Emissivity 0.1~1.00 adjustable (0.95 by default)
Infrared Wavelength Range 8~14um
Temperature Range -20℃~+550℃
Temperature Measurement Error ±2℃ or ±2%
Measurement Resolution 0.1℃/0.1℉
Measuring Distance 0.3m~2m
Visible Light Output Pixels 240x240 pixels
Gain Mode Auto Gain
Color Palette Iron Red, Rainbow, Fusion, White Heat, Red Heat
Multimeter Parameters
DC Maximum Input Voltage 1000V
AC Maximum Input Voltage 750V
Maximum Current Measurement 10A
Maximum Resistance 99.99MΩ
Maximum Capacitance 199.99mF
Duty Cycle Test Range 0.1% ~ 99.9%
Diode Test Range 0V ~ 3V
Continuity Test 199.99Ω
Display Word Count 19999 counts, Updates 3/sec
Infographic detailing the rich performance features of the thermal imaging multimeter, including IPS screen, auto temperature tracking, dual light fusion, multi-point measurement, over-temperature alarm, adjustable emissivity, one-click screenshot, PC software support, AC/DC voltage/current, resistance, capacitance, on/off buzzing, diode, frequency, LIVE, HOLD, NCV detection, auto shutdown, and intelligent screen shutdown.
Figure 10: Rich Performance Features

10. User Tips

Based on general user feedback for similar devices, here are some tips for optimal use:

  • Emissivity Adjustment: For accurate temperature readings, ensure the emissivity setting matches the material being measured. Common materials have different emissivity values.
  • Focus on Hot Spots: When using thermal imaging, scan the area broadly first, then focus on any identified hot or cold spots for more detailed analysis.
  • Regular Charging: To prolong battery life, avoid completely draining the battery frequently. Charge it regularly, especially after heavy use.
  • Software Updates: Check the manufacturer's website periodically for any available firmware or PC software updates to ensure optimal performance and new features.

11. Warranty and Support

Your TOOLTOP ET11S Pro Thermal Imaging Multimeter is covered by a manufacturer's warranty. Please refer to the warranty card included in your package for specific terms and conditions. For technical support, troubleshooting assistance, or warranty claims, please contact the seller or manufacturer directly.

Note: Unauthorized repairs or modifications may void your warranty.


TOOLTOP ET11S PRO Thermal Imaging Multimeter: 2-in-1 IR Camera & Electrical Tester

TOOLTOP ET11S PRO Thermal Imaging Multimeter: 2-in-1 IR Camera & Electrical Tester

0:55 • 1280×720 • feature_demo