1. Introduction
Thank you for choosing the Anern FGI-S12000 Solar Hybrid Inverter. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your inverter. The FGI-S12000 is a 12KW, 48V inverter featuring dual PV input, dual AC output, and an advanced MPPT 160A solar charger, designed for seamless integration with both lithium and lead-acid battery systems, including BMS communication.

2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly sized and properly insulated.
- Do not attempt to repair the inverter yourself. Contact qualified service personnel.
- Disconnect all power sources (PV, battery, AC grid) before performing any maintenance or wiring.
- The inverter generates high voltage and current. Exercise extreme caution.
3. Product Overview
The Anern FGI-S12000 is a high-performance solar hybrid inverter designed for robust energy management. It integrates a powerful MPPT solar charger, an inverter, and a battery charger into a single unit. Key features include:
- High Power Output: 12KW rated output power.
- Dual PV Input: Supports up to 15000W Max PV Output Power with dual inputs (22.5A * 2).
- Dual AC Output: Configurable second output based on voltage, output duration, and battery State of Charge (SOC).
- Wide Compatibility: Compatible with various battery types including AGM, GEL, FLD, SLD, and LiFePO4.
- Advanced Charging: MPPT 160A Max Charge Current (PV+AC).
- BMS Communication: Ensures optimal performance and safety with compatible lithium batteries.
- Monitoring: Optional Wi-Fi module for remote monitoring via iOS and Android applications.
- Pure Sine Wave Output: Provides clean and stable power for sensitive electronics.


4. Specifications
Below are the detailed technical specifications for the Anern FGI-S12000 Solar Hybrid Inverter:

| Category | Parameter | Value |
|---|---|---|
| AC Input | Rated Input Voltage (VAC) | 220/230/240; L+N+PE |
| Voltage Range (VAC) | 90-280 (APP mode); 170-280 (UPS mode) | |
| Frequency (Hz) | 50/60 (Auto Adaptive) | |
| AC Output | Rated Capacity (kW) | 12 (Max current of AC output 1 is 70A. Max current of AC output 2 is 40A) |
| Surge Power (kVA) | 24 | |
| Voltage (VAC) | 220/230/240 | |
| Power Factor (PF) | 1 | |
| Frequency (Hz) | 50/60±0.1% | |
| Switch Time (ms) | 10 (APP/UPS mode) / 20 (GEN mode) | |
| WaveForm | Pure SineWave | |
| Overload Capacity | 102%-125% load | 1min |
| >125% load | 10s | |
| Max. Efficiency | Battery Mode | 94%@48V |
| Charger (PV/AC) | Solar Charger Type | MPPT |
| Max PV Input Current/Power | Single PV Input: 27A/9000W; Dual PV Input: 22.5*2A/15000W | |
| MPPT Range@Operating Voltage (VDC) | 60-450 | |
| PV Start-up Voltage | 80Vdc | |
| Max PV Open Circuit Voltage (VDC) | 500 | |
| Max PV Charge Current (A) | 160 | |
| Battery | Normal Voltage (VDC) | 48 |
| Battery Type | Lithium and Lead-acid | |
| General Data | HMI | LCD |
| Interface | RS232/RS485/CAN | |
| Monitoring | WiFi(Optional) | |
| Ingress Protection | IP21 | |
| Operating Temperature | -10°C~60°C | |
| Relative Humidity | 5%~95% (Non-condensing) | |
| Storage Temperature | -15°C~60°C | |
| Max. Operating Altitude | 4000m (Derating above 1000m) |
5. Installation and Setup
Proper installation is crucial for the safe and efficient operation of your solar hybrid inverter. Always ensure all power sources are disconnected before beginning installation.
5.1 System Diagram
The following diagram illustrates a typical solar energy storage system setup with the Anern FGI-S12000 inverter:

5.2 Battery Connection
The inverter supports both lead-acid and lithium batteries. Ensure correct polarity and secure connections.

5.2.1 Lead-acid Battery Connection
Select a lead-acid battery with appropriate capacity and a nominal voltage of 48V. You must also specify the battery type (e.g., 'AGM' or 'FLD' for flooded batteries) in the inverter settings for optimal charging.
5.2.2 Lithium Battery Connection
If using a lithium battery, first verify the compatibility of its communication protocol with the inverter. Lithium batteries typically have two connectors: an RJ45 port for BMS communication and a power cable for connection to the inverter's BAT+ and BAT- terminals.
5.3 PV Input Connection
Connect your solar panels to the PV1 and PV2 inputs. Ensure the total PV array open circuit voltage does not exceed 500V and the maximum input current/power for single or dual PV inputs is respected (Single PV Input: 27A/9000W; Dual PV Input: 22.5*2A/15000W).
5.4 AC Input/Output Connection
Connect the AC grid input to the 'AC IN' terminal. Connect your home loads to the 'OUT1' and 'OUT2' terminals. The second output ('OUT2') can be configured for specific operational modes.
5.5 Optional Wi-Fi Module Installation
If you have purchased the optional Wi-Fi module, install it into the designated port on the inverter. This enables remote monitoring and control via the mobile application.
6. Operation
Once installed, the inverter can be operated via its LCD Human-Machine Interface (HMI) or remotely through the optional Wi-Fi module and mobile app.
6.1 Initial Power-Up
- Ensure all connections are secure and correct.
- Turn on the battery breaker.
- Turn on the PV array breaker (if applicable).
- Turn on the AC input breaker (if applicable).
- Turn on the inverter's main power switch.
- Observe the LCD display for system status and any error messages.
6.2 LCD Display and Interface
The LCD provides real-time system information, including input/output voltages, currents, power, battery status, and operational modes. Use the navigation buttons to browse menus and adjust settings. The inverter also supports RS232/RS485/CAN communication for advanced integration.
6.3 Dual AC Output Configuration
The second AC output (OUT2) can be configured through the inverter's settings. This allows for flexible power management, such as prioritizing certain loads or providing power for a specific duration based on battery SOC or other parameters.
6.4 Wi-Fi Monitoring (Optional)
If the Wi-Fi module is installed, download the dedicated Anern monitoring application for iOS or Android. Follow the app's instructions to connect your inverter to the cloud and enable remote monitoring of system performance, energy production, consumption, and battery status.

7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust accumulation, which can lead to overheating. Use a dry, soft cloth.
- Connection Checks: Annually inspect all electrical connections (PV, battery, AC) for tightness and signs of corrosion.
- Firmware Updates: Check the manufacturer's website or app for available firmware updates to ensure your inverter has the latest features and bug fixes.
- Environmental Conditions: Ensure the inverter operates within its specified temperature and humidity ranges (-10°C to 60°C, 5%-95% non-condensing relative humidity).
8. Troubleshooting
This section covers common issues and their potential solutions. For complex problems, contact technical support.
- Inverter Not Turning On: Check battery connections, battery voltage, and all circuit breakers (battery, PV, AC).
- No AC Output: Verify AC output breaker, check for overload conditions, and ensure the inverter is in the correct operating mode.
- Low Power Output: Inspect PV panel cleanliness, shading, and connections. Check battery health and charge level.
- Error Codes on LCD: Refer to the inverter's detailed error code list (usually found in the full product manual or manufacturer's support documentation) for specific diagnostic steps.
- Wi-Fi Monitoring Issues: Ensure the Wi-Fi module is correctly installed and connected. Check your internet connection and router settings. Restart the inverter and the mobile app.
9. User Tips
- Battery Compatibility: Always confirm the compatibility of your chosen battery type, especially for lithium batteries, to ensure proper BMS communication and charging protocols.
- Optimal Placement: Install the inverter in a well-ventilated area, away from direct sunlight and moisture, to prevent overheating and ensure efficient operation.
- Regular Monitoring: Utilize the optional Wi-Fi monitoring feature to keep track of your system's performance and identify potential issues early.
10. Warranty and Support
For warranty information, technical support, or service requests, please contact your vendor or the official Anern customer service. Keep your purchase receipt and product serial number handy for faster service. Do not attempt to open or repair the inverter yourself, as this may void the warranty.