PowMr POW-LVM4K-24V

Contents

PowMr 4KW 120V Off Grid Solar Inverter User Manual

Model: POW-LVM4K-24V

Brand: PowMr

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the PowMr 4KW 120V Off Grid Solar Inverter. Please read this manual carefully before installations and operations. Keep this manual for future reference.

1.1. Features

  • Off-grid solar inverter
  • No battery function available (can operate without battery)
  • Under Battery Mode, AC voltage can be adjusted to 100VAC, 110VAC, and 120VAC.
  • Utility power, battery, and PV power complement each other.
  • Pure sine wave solar inverter.
  • Unique glass top cover design with 6.25-inch LCD display and touchable buttons.
  • Built-in 150A MPPT (Max PV 5600W) solar charger.
  • High PV input range from 55V-350Vdc.
  • Smart battery charger design for optimized battery performance.
  • Configurable AC/Battery input priority via LCD setting.
  • Auto restart while PV is recovering.
  • Over-load, over temperature, and output short circuit protection.
  • Cold restart function.
  • Built-in lithium battery automatic activation.
  • Communication with RS232/RS485.
  • WiFi monitoring function (optional).
  • Anti-dust kit for harsh environment (optional).
  • Restore default settings with one click.

1.2. Basic System Architecture

The following illustration shows a basic application for this inverter/charger. It includes a generator or utility, and PV modules (optional).

Diagram of a Hybrid Power System showing solar panels, inverter, battery, and home appliances.
Figure 1: Hybrid Power System Overview

This inverter can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION – To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION – Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
  10. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  11. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Setup (Installation)

3.1. Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:

  • The unit x 1
  • User manual x 1

3.2. Preparation

Before connecting all wirings, take off the bottom cover by removing two screws.

3.3. Mounting the Unit

Consider the following points before selecting where to install:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level in order to allow the LCD display to be read at all times.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Front view of the PowMr Hybrid Inverter with LCD display and control buttons.
Figure 2: PowMr Hybrid Inverter Front View

3.4. Battery Connection

CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. Please refer to the table below for required fuse or breaker size.

WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, use the proper recommended cable and terminal size as below.

Recommended Battery Cable and Terminal Size
ModelTypical AmperageBattery CapacityWire SizeCable mm²Ring Terminal D (mm)Ring Terminal L (mm)Ring Terminal M (mm)Torque Value
3.0KW 24V110A100AH1*4AWG2284418.22~3 Nm
200AH84418.2
4.0KW 24V150A200AH1*2AWG3584418.22~3 Nm

Follow these steps to implement battery connection:

  1. Assemble battery ring terminal based on recommended battery cable and terminal size.
  2. Connect all battery packs as units require.
  3. Insert the ring terminal of battery cable flatly into the battery connector of the inverter and make sure the bolts are tightened with a torque of 2-3 Nm. Ensure polarity at both the battery and the inverter/charger is correctly connected and ring terminals are tightly screwed to the battery terminals.

NOTE: Please only use sealed lead-acid battery or sealed GEL/AGM lead-acid battery or lithium battery.

WARNING: Shock Hazard - Installation must be performed with care due to high battery voltage in series.

CAUTION!! Do not place anything between the flat part of the inverter terminal and the ring terminal. Otherwise, overheating may occur. Do not apply anti-oxidant substance on the terminals before terminals are connected tightly. Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

3.5. AC Input/Output Connection

CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec of AC breaker is 40A for 4.0KW.

CAUTION!! There are two terminal blocks with “INPUT” and “OUTPUT” markings. Please do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, use the proper recommended cable size as below.

Suggested Cable Requirement for AC Wires
ModelGaugeTorque Value
3.0KW10 AWG1.2~1.6 Nm
4.0KW8 AWG1.4~1.6Nm

Follow these steps to implement AC input/output connection:

  1. Before making AC input/output connection, be sure to open DC protector or disconnector first.
  2. Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N 3 mm.
  3. Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws.
  4. Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws. Be sure to connect PE protective conductor (Ground, green) first.
  5. Make sure the wires are securely connected.

WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.

CAUTION: Important - Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are worked in parallel operation.

CAUTION: Appliances such as air conditioners require at least 2-3 minutes to restart. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. Check the air conditioner manufacturer for time-delay function before installation. Otherwise, this inverter/charger may trigger overload fault and cut off output to protect your appliance, but sometimes it still causes internal damage to the air conditioner.

3.6. PV Connection

CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.

WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, use the proper recommended cable size as below.

Recommended PV Module Cable Size
ModelWire SizeCable (mm²)Torque Value (max)
3.0KW/4.0KW1 x 12AWG41.2 Nm

3.6.1. PV Module Selection

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than min. PV Array MPPT Voltage range.
PV Array Voltage Range
INVERTER MODEL3.0KW4.0KW
Max. PV Array Open Circuit Voltage350Vdc
PV Array MPPT Voltage Range55Vdc~350Vdc

Follow these steps to implement PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
  3. Make sure the wires are securely connected.

3.7. Final Assembly

After connecting all wirings, put the bottom cover back by screwing two screws.

4. Operating Instructions

4.1. Power ON/OFF

Once the unit has been properly installed and the batteries are connected well, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

4.2. Operation and Display Panel

The operation and display panel, located on the front panel of the inverter, includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

4.2.1. LED Indicator Messages

LED IndicatorColorStateMessage
AC INVGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.

4.2.2. Function Keys

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4.3. LCD Display Icons

The LCD display provides various information about the inverter's status and performance. Key icons include:

  • Input Source Information: Icons for AC input and PV input.
  • Configuration Program and Fault Information: Indicates setting programs, warning codes (flashing), and fault codes (solid).
  • Output Information: Displays output voltage, frequency, load percent, load in VA, load in Watt, and discharging current.
  • Battery Information: Left side flashing bar and battery icon indicate battery level (0-20%, 20-40%, 40-60%, and 80-100%) in battery mode and charging status in line mode.
  • Load Information: Icons for overload, and load level by percentage (0-24%, 25-50%, 50-75%, and 75-100%).
  • Mode Operation Information: Icons indicating connection to mains, PV panel, load supplied by utility power, utility charger circuit working, and DC/AC inverter circuit working.
  • Mute Operation: Icon indicates unit alarm is disabled.

4.4. LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the “UP” or “DOWN” buttons to select setting programs, then press “ENTER” to confirm or “ESC” to exit.

Key configurable settings include:

  • Output source priority (Program 01): Configure whether solar energy or utility/battery is prioritized for loads.
  • Maximum charging current (Program 02): Set total charging current for solar and utility chargers.
  • AC input voltage range (Program 03): Select between Appliance (90-140 VAC) or UPS (90-140 VAC) modes.
  • Power saving mode (Program 04): Enable or disable power saving.
  • Battery type (Program 05): Select battery type (AGM, Flooded, Lithium, User-Defined, Lithium with communication).
  • Auto restart functions (Program 06, 07): Enable/disable auto restart after overload or over temperature.
  • Output voltage (Program 08): Set output voltage (100VAC, 110VAC, 120VAC).
  • Output frequency (Program 09): Set output frequency (50Hz/60Hz).
  • Setting voltage point back to utility source (Program 12): For SBU priority.
  • Setting voltage point back to battery mode (Program 13): For SBU priority.
  • Charger source priority (Program 16): Prioritize solar, solar and utility, or only solar for charging.
  • Alarm control (Program 18): Enable or disable alarms.
  • Auto return to default display screen (Program 19): Configure display behavior.
  • Backlight control (Program 20): Turn backlight on or off.
  • Beeps while primary source is interrupted (Program 22): Enable or disable beeps.
  • Record Fault code (Program 25): Enable or disable fault code recording.
  • Bulk charging voltage (Program 26): Set C.V voltage for charging.
  • Floating charging voltage (Program 27): Set charging recovery voltage.
  • Low DC cut-off voltage (Program 29): Set the low DC cut-off voltage.
  • Restore default settings (Program 30): Reset inverter to factory defaults.

4.5. Lithium Battery Connection and Setting

If the inverter is matched with lithium batteries, only lithium batteries that have been matched with the BMS communication protocol are allowed to be used.

Follow these steps to implement lithium battery connection:

  1. Assemble battery ring terminal based on recommended battery cable and terminal specifications.
  2. Insert the ring terminal of battery cable flatly into battery connector of inverter and make sure the bolts are tightened with torque of 2-3Nm. Make sure polarity at both the battery and the inverter/charge is correctly connected and ring terminals are tightly screwed to the battery terminals.
  3. Connect the RJ45 connector to the COMM port on the inverter.
  4. Connect the other end of the RJ45 plug to the battery communication port (RS485). Ensure that the battery signal cable RS485-A is connected to the RS485-A of the COMM port, and the battery signal cable RS485-B is connected to the RS485-B of the COMM port.

NOTE: If choosing lithium battery, make sure to connect the BMS communication cable between the battery and the inverter. You need to choose battery type as “Lib-485” mode in Program 5.

4.5.1. Communication Port Pin Definition

Communication Port Pin Definition
Pin numberDefinition
1RX
2TX
3VCC
4VCC
5RS485-A
6RS485-B
7GND
8GND

4.5.2. Lithium Battery Information Display

After pressing and holding the “ESC” button for 3 seconds, enter the lithium battery page. The initial display interface indicates the total battery voltage and remaining battery capacity.

When the battery type is set to “Lib-485”, the settings of Program 12, 13, and 29 are adjusted for SOC (State of Charge) percentages. The default charging current is 0.5C. If communication fails, the inverter will cut off output.

4.6. Display Setting

The LCD display information can be switched by pressing the “UP” or “DOWN” key. Selectable information includes: input voltage, input frequency, PV voltage, MPPT charging current, MPPT charging power, battery voltage, output voltage, output frequency, load percentage, load in VA, load in Watt, DC discharging current, and main CPU Version.

4.7. Operating Mode Description

The inverter supports various operating modes:

  • Standby mode / Power saving mode: In standby, the inverter is not turned on but can charge the battery without AC output. In power saving, the output is off when the connected load is very low or not detected.
  • Line Mode: The unit provides output power from the mains and charges the battery.
  • Battery Mode: The unit provides output power from battery and PV power.

5. Maintenance

5.1. Battery Equalization

The equalization function is added to the charge controller to reverse the buildup of negative chemical effects like stratification and to remove sulfate crystals from battery plates. It's recommended to equalize the battery periodically.

5.1.1. How to Apply Equalization Function

You must enable the battery equalization function in monitoring LCD setting program 33 first. Then, you may apply this function by either of the following methods:

  1. Setting equalization interval in program 37.
  2. Active equalization immediately in program 39.

5.1.2. When to Equalize

In the float stage, when the setting equalization interval (battery equalization cycle) is reached, or equalization is active immediately, the controller will start to enter the Equalize stage.

5.1.3. Equalize Charging Time and Timeout

In the Equalize stage, the controller will supply power to charge the battery as much as possible until the battery voltage rises to the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until the setting battery equalized time is reached.

If the battery equalized time expires and the battery voltage doesn't rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltage. If the battery voltage is still lower than the equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.

5.2. General Maintenance Tips

  • Keep the inverter clean and free from dust. The dust-proof cover helps, but periodic cleaning of external surfaces is recommended.
  • Regularly check all connections (battery, AC input/output, PV) to ensure they are tight and free from corrosion.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Monitor the LCD display for any warning indicators or fault codes and address them promptly.

6. Troubleshooting

This section provides solutions to common problems encountered with the inverter. If errors persist after following these steps, contact a qualified service center.

Troubleshooting Guide
ProblemLCD/LED/BuzzerExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer active for 3 seconds then off.The battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. Battery voltage is far too low (<1.4V/Cell)
2. Battery polarity is connected reversed.
1. Check if batteries and wiring are connected well.
2. Re-charge battery.
3. Replace battery.
Input voltage displayed as 0 on LCD, green LED flashing.Input protector is trippedCheck if AC breaker is tripped and AC wiring is connected well.
Mains exist but unit works in battery mode.Green LED is flashing.Insufficient quality of AC power (Shore or Generator)1. Check if AC wires are too thin and/or too long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS/Appliance).
Green LED is flashing.Set "Solar First" as the priority of output source.Change output source priority to Utility first.
When unit is turned on, internal relay switches on and off repeatedly.LCD display and LEDs are flashing.Battery is disconnected.Check if battery wires are connected well.
Buzzer beeps continuously and red LED is on.Fault code 07Overload error. Inverter is overload 110% and time is up.Reduce the connected load by switching off some equipment.
Fault code 05Output short circuited.Check if wiring is connected well and remove abnormal load.
Fault code 02Internal temperature of inverter component is over 120°C.Check whether air flow is blocked or ambient temperature is too high.
Fault code 03Battery is over-charged.Return to repair center.
Fault code 01Fan fault.Replace the fan.
Fault code 06/58Output abnormal (Inverter voltage below 190Vac or higher than 260Vac)1. Reduce the connected load.
2. Return to repair center.
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart the unit, if the error happens again, please return to repair center.
Fault code 56Battery is not connected well or fuse is burnt.If the battery is connected well, please return to repair center.

6.1. Fault Reference Code

The manual provides a detailed list of fault codes and their corresponding events. For example:

  • 01: Fan is locked when inverter is off.
  • 02: Over temperature.
  • 03: Battery voltage is too high.
  • 04: Battery voltage is too low.
  • 05: Output short circuited or over temperature detected by internal converter components.
  • 51: Over current or surge.

6.2. Warning Indicator

The inverter also provides warning indicators for various conditions:

  • 01: Fan is locked when inverter is on (Beep twice every second).
  • 03: Battery is over-charged (Beep twice every second).
  • 04: Low battery (Beep twice every second).
  • 07: Overload (Beep twice every second).
  • 15: PV is weak.
  • 61: When the battery communication is abnormal, stop charging and discharging.

7. Specifications

7.1. Line Mode Specifications

INVERTER MODEL3.0KW/24V4.0KW/24V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage120Vac
Low Loss Voltage95Vac±5V(UPS); 65Vac±7V(Appliances)
Low Loss Return Voltage100Vac±5V(UPS); 70Vac±5V(Appliances)
High Loss Voltage140Vac±5V
High Loss Return Voltage135Vac±5V
Max AC Input Voltage150Vac
Nominal Input Frequency50Hz / 60Hz (It can be set in program 09)
Low Loss Frequency45±1Hz/55±1Hz
Low Loss Return Frequency47±1Hz/57±1Hz
High Loss Frequency55±1Hz/65±1Hz
High Loss Return Frequency53±1Hz/63±1Hz
Output Short Circuit ProtectionLine mode: Circuit Breaker; Battery mode: Electronic Circuits
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

7.2. Inverter Mode Specifications

INVERTER MODEL3.0KW/24V4.0KW/24V
Rated Output Power3.0KW4.0KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation120Vac±5%
Output Frequency60Hz or 50Hz
Peak Efficiency94%
Overload Protection5s@≥150% load; 10s@110%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24Vdc
Cold Start Voltage23.0Vdc
Low DC Warning Voltage22.0Vdc
Low DC Warning Return Voltage23.0Vdc
Low DC Cut-off Voltage21.0Vdc
High DC Recovery Voltage29Vdc
High DC Cut-off Voltage31Vdc
No Load Power Consumption<35W

7.3. Charge Mode Specifications

7.3.1. Utility Charging Mode

INVERTER MODEL3.0KW/24V4.0KW/24V
Charging Current (UPS) @ Nominal Input Voltage80A110A
Bulk Charging Voltage (Flooded Battery)29.2Vdc
Bulk Charging Voltage (AGM / Gel Battery)28.2Vdc
Floating Charging Voltage27Vdc
Charging Algorithm3-Step

7.3.2. Solar Charging Mode

INVERTER MODEL3.0KW/24V4.0KW/24V
Rated Power5600W
PV Charge Current100A140A
Efficiency98.0% max.
Max. PV Array Open Circuit Voltage350Vdc
PV Array MPPT Voltage Range55-350Vdc
Standby Power Consumption2W
Battery Voltage Accuracy+/-0.3%
PV Voltage Accuracy+/-2V
Charging Algorithm3-Step

7.4. General Specifications

INVERTER MODEL3.0KW/24V4.0KW/24V
Safety CertificationCE
Operating Temperature Range0°C to 55°C
Storage temperature-15°C~60°C
Dimension (D*W*H), mm400*250*89mm
Net Weight, kg7.5kg8.5kg

Note: Backup time depends on the quality of the battery, age of battery, and type of battery. Specifications of batteries may vary depending on different manufacturers.

* Product technical specifications are subject to change without notice.

8. User Tips

  • Voltage Compatibility: This inverter is designed for 110V/120V AC output. Always verify your local grid voltage and appliance requirements before installation to ensure compatibility.
  • Battery Type Selection: Ensure the correct battery type (AGM, Flooded, Lithium, User-Defined) is selected in Program 05 of the LCD settings for optimal performance and battery longevity. For lithium batteries, proper BMS communication setup is crucial.
  • Heat Dissipation: The inverter features cooling fans and a smart design for heat dissipation. Ensure the unit is mounted in a location with sufficient airflow and clear space around it to prevent overheating, especially in harsh environments.
  • Dust Prevention: The dust-proof cover helps protect internal components. Periodically inspect and clean the exterior to maintain its effectiveness.

9. Warranty and Support

For technical support, service, or warranty inquiries, please contact the manufacturer using the information below:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

Tel/Fax: +86755-28219903

Email: Support@powmr.com

Web: www.powmr.com

Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Please refer to the official user manual PDF for additional details and the most up-to-date information: User manual (PDF)