1. Product Overview

The ELECTESLA ES-PC2088 is a high-performance LCD Pressure Transmitter designed for precise measurement of various pressure types including gauge, absolute, sealing, negative, and vacuum pressure in gaseous, liquid, and water media. It features multiple output signals (4-20mA, RS485) and a robust 304 Stainless Steel housing with IP65 protection, making it suitable for a wide range of industrial applications.

ELECTESLA ES-PC2088 LCD Pressure Transmitter with key features

Figure 1: ELECTESLA ES-PC2088 LCD Pressure Transmitter

Key features include:

  • Wide Measuring Range: -1-0-1000bar
  • Versatile Output: 4-20mA, RS485
  • Power Supply: DC12V, DC24V
  • Multiple Thread Options: M20*1.5, G1/2, G1/4, NPT 1/2 1/4
  • Certifications: CE, FCC, RoHS
  • High Accuracy: 0.2%F.S., 0.5%F.S. (Default)
  • Durable Construction: 304 Stainless Steel housing, IP65 Protection

2. Setup and Installation

2.1 Unpacking

Carefully remove the pressure transmitter from its packaging. Inspect the device for any visible damage. Ensure all components are present as per the packing list.

ELECTESLA ES-PC2088 LCD Pressure Transmitter in its packaging

Figure 2: Product in packaging

2.2 Mechanical Installation

Select the appropriate thread size (M20*1.5, G1/2, G1/4, NPT 1/2 1/4) for your application. Ensure a secure and leak-free connection to the pressure source. Use appropriate sealing materials if necessary. Refer to the dimensional drawing for precise measurements.

Dimensional drawing of the pressure transmitter

Figure 3: Dimensional Drawing (Dimensions in mm)

2.3 Electrical Wiring

WARNING: Disconnect power before wiring. Improper wiring can cause damage to the device or personal injury.

The transmitter supports 2-wire current output, 3-wire voltage output, and 4-wire RS485 communication. Follow the specific wiring diagram for your chosen output type.

Wiring diagrams for 2-wire current, 3-wire voltage, and 4-wire RS485 outputs

Figure 4: Wiring Diagrams

  • 2-wire Current Output (4-20mA):
    • Red wire (PIN1): Connect to +24VDC Power.
    • Black wire (PIN2): Connect to 4-20mA Instruments (Current output).
  • 3-wire Voltage Output (1-5V, 0-10V):
    • Red wire (PIN1): Connect to +24VDC Power.
    • Black wire (PIN3): Connect to -24VDC Power (Common).
    • Yellow wire (PIN2): Connect to Voltage output Instruments.
  • 4-wire RS485 Communication:
    • Red wire (PIN1): Connect to +24VDC Power.
    • Black wire (PIN3): Connect to -24VDC Power.
    • Blue wire (PIN2): Connect to RS485 A terminal on instruments.
    • Yellow wire (PIN4): Connect to RS485 B terminal on instruments.

Ensure proper polarity and secure connections to prevent damage.

3. Operating Instructions

3.1 Power On

Once the transmitter is correctly installed and wired, apply the specified DC12V or DC24V power supply. The LCD display will illuminate, showing the current pressure reading.

Front view of the pressure transmitter with digital display

Figure 5: Transmitter Display

3.2 Reading Pressure

The LCD display provides a real-time digital readout of the measured pressure. The unit of measurement (e.g., MPa, bar) will be indicated on the display. For RS485 output, connect to a compatible Modbus master device to read data.

3.3 Zero and Span Adjustment (if applicable)

Some models may feature buttons for zero and span adjustment. Consult the specific model's interface for details on calibration procedures. Typically, a 'SET' button or similar is used to enter calibration mode, and arrow buttons to adjust values.

4. Maintenance

  • Regular Inspection: Periodically check the transmitter for any signs of physical damage, corrosion, or loose connections.
  • Cleaning: Keep the device clean, especially the display and electrical connections. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges to maintain optimal performance and longevity.
  • Recalibration: Depending on the application and required accuracy, periodic recalibration may be necessary. Consult a qualified technician for calibration services.

5. Troubleshooting

Problem Possible Cause Solution
No display/No power Incorrect power supply voltage; Loose wiring; No power to circuit. Verify power supply (DC12V/DC24V); Check all wiring connections; Ensure power is supplied.
Inaccurate readings Sensor not properly installed; Calibration required; Incorrect measuring range selected. Ensure proper mechanical installation; Perform zero/span adjustment or recalibration; Confirm the selected model matches the required measuring range.
No output signal Incorrect wiring for output type; Faulty receiving instrument; Damaged transmitter. Check wiring against diagrams (Figure 4); Test with a known good receiving instrument; Contact support if transmitter is suspected to be faulty.
Display shows error code Internal fault; Sensor issue. Power cycle the device. If the error persists, contact technical support with the error code.

6. Specifications

Parameter Value
Model ES-PC2088 (or 2088 pressure transmitter)
Measuring Range -1-0-1000bar (-0.1...0...100Mpa)
Output Signal 4-20mA, RS485, 1-5V, 0-10V
Power Supply DC12V; DC24V (18V-32VDC, Default 24VDC)
Accuracy 0.1%F.S., 0.25%F.S., 0.5%F.S. (standard/Default)
Thread Size M20*1.5, G1/2, G1/4, NPT1/2, NPT1/4
Response Time ≤10ms
Protection Class IP65
Overload Capacity 200%F.S.
Housing Material 304 Stainless Steel, Aluminum housing
Diaphragm Material SS316L
Long-term Stability ≤0.2%F.S./year
Temperature Drift ≤0.03%F.S./°C
Operating Temperature -15°C-70°C
Compensation Temperature -10~70°C (Standard), -10~400°C (High Temperature type)
Medium Temperature -40~80°C
Environment Temperature -40~85°C
Measuring Media Gaseous, Liquid, Water
Pressure Type Gauge pressure, Absolute pressure, Sealing pressure, Negative pressure, Vacuum pressure
Display Type No display, LED, LCD
Inherent Frequency 5kHz~650kHz
Battery Included No
High-concerned chemical None
Certification CE, FCC, RoHS
Detailed specifications table and dimensions

Figure 6: Product Specifications and Dimensions

7. User Tips

No specific user tips were available from customer reviews or Q&A for this product. General best practices for pressure transmitters include:

  • Always ensure the pressure range of the transmitter matches or exceeds the maximum expected pressure in your application.
  • Protect the device from excessive vibration or mechanical shock.
  • When installing, avoid overtightening the thread connection to prevent damage to the sensor or the process connection.
  • For critical applications, consider redundant measurements or regular calibration checks.

8. Warranty and Support

ELECTESLA is committed to providing reliable products and support. For any technical assistance, warranty claims, or inquiries, please contact us:

  • WhatsApp: +8615665610693
  • Email: sales02@jinqu-electric.com

The product is designed for durability and performance, backed by standard industry practices for quality and reliability.

Play video
Watch video online

Video: ELECTESLA Pressure Transmitters Product Showcase

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.