Hantek TO1112 TO1112C TO1112D TO1154D TO1204D TO1254D

Contents

Hantek TO1000 Series Multi-function Digital Oscilloscope User Manual

Models: TO1112, TO1112C, TO1112D, TO1154D, TO1204D, TO1254D

Brand: Hantek

1. Introduction

The Hantek TO1000 series represents a new generation of multi-function digital oscilloscopes designed for portability and versatility. Featuring a thin, lightweight body and a full multi-touch screen, these devices integrate an oscilloscope, multimeter, signal generator, and spectrum analyzer into a single unit. The unique hanging design enhances usability, while the anti-fall and shock-resistant construction ensures durability. Equipped with a large-capacity battery and fast-charging support, the TO1000 series is built for extended use in various environments.

Video: Hantek TO1000 Series Product Overview, highlighting its thin design, multi-functionality, and robust build.

2. Setup

2.1 Unboxing and Package Contents

Carefully unpack your Hantek TO1000 series oscilloscope and verify all components are present. The standard package typically includes:

  • Hantek TO1000 Series Host Unit
  • Oscilloscope Probe(s) (Quantity varies by model: one for two-channel series, two for four-channel series)
  • Multimeter Probe (for TO1000C/D Series)
  • 18W Adapter
  • Type-C Charging Cable
  • Instrument Package (Carrying Case)
Hantek TO1254D Oscilloscope with all included accessories: carrying case, charger, Type-C cable, multimeter probes, and oscilloscope probes.

Image: Complete package contents for the Hantek TO1000 series oscilloscope.

2.2 Charging the Device

Before initial use, ensure the device is fully charged. The TO1000 series features a built-in 10000mAh removable lithium battery and supports fast charging via its Type-C port.

  1. Connect the provided 18W adapter to a power outlet.
  2. Connect the Type-C charging cable to the adapter and the Type-C port on the side of the oscilloscope.
  3. The device will indicate charging status on the screen. A full charge provides long-lasting battery life, with standby time up to half a year.
18W adapter and Type-C charging cable for the Hantek oscilloscope.

Image: The 18W adapter and Type-C charging cable.

Side view of the Hantek oscilloscope showing the Type-C charging port with '9V2A Fast Charging' text.

Image: The Type-C charging port, supporting 9V2A fast charging.

Rear view of the Hantek oscilloscope with the battery compartment open, showing four 18650 batteries.

Image: Battery compartment for 4x 18650 batteries, providing 10000mAh capacity.

2.3 Initial Power On

Press and hold the power button to turn on the device. The multi-touch screen will display the main menu, offering various functions such as Oscilloscope (OSC), Digital Multimeter (DMM), Arbitrary Function Generator (AFG), File Browser, Settings, and Pictures.

Hantek oscilloscope main screen showing icons for OSC, DMM, AFG, File Browser, Settings, and Pictures.

Image: Main menu interface of the Hantek TO1000 series.

3. Operating Instructions

The Hantek TO1000 series features a multi-touch screen for intuitive operation. Navigate through functions and adjust settings by tapping and swiping.

3.1 Oscilloscope (OSC) Mode

The oscilloscope function allows for waveform visualization and analysis with up to 4 channels, a maximum bandwidth of 250MHz, a sampling rate of 1GS/s, and an 8M storage depth.

  1. Connect Probes: Connect the oscilloscope probes to the BNC connectors on the device (CH1, CH2, CH3, CH4). Ensure proper grounding.
  2. Select OSC Mode: Tap the 'OSC' icon on the main menu.
  3. Adjust Settings: Use the touch screen to adjust vertical scale (V/div), horizontal scale (s/div), trigger type (edge, slope, pulse width, video, timeout), and trigger level.
  4. Waveform Display: Observe the waveforms on the screen. The device supports up to 42 measurement functions for detailed analysis.
  5. One-Key Waveform Storage: Utilize the one-key storage feature for quick saving of waveforms.
Oscilloscope display showing multiple waveforms in different colors.

Image: Multi-channel waveform display in Oscilloscope mode.

Oscilloscope probe with a user's guide.

Image: Oscilloscope probe, essential for waveform acquisition.

Top view of the Hantek oscilloscope showing BNC connectors for channels CH1-CH4 and AFG output.

Image: BNC input connectors for oscilloscope channels and AFG output.

A finger interacting with the oscilloscope touch screen, zooming in on a waveform.

Image: Touch screen interaction for zooming and adjusting waveforms.

3.2 Digital Multimeter (DMM) Mode

The DMM function provides high-precision measurements for various electrical parameters, including data recording and trend analysis.

  1. Connect Probes: Connect the multimeter probes to the dedicated input terminals (V/Ω/C, COM, mA, A) on the side of the device.
  2. Select DMM Mode: Tap the 'DMM' icon on the main menu.
  3. Select Measurement Type: Choose between AC/DC voltage, current, resistance, capacitance, diode, or continuity test.
  4. Perform Measurement: Apply the probes to the circuit or component under test. Readings will be displayed on the screen.
  5. Data Recording: The multimeter can record data changes over time, generating trend graphs or allowing data export for further analysis.
Multimeter display showing voltage readings and trend graph.

Image: Digital Multimeter display showing voltage measurement and data recording features.

Red and black multimeter probes.

Image: Multimeter probes for various measurements.

Side view of the Hantek oscilloscope showing multimeter input terminals for V/Ω/C, COM, mA, and A.

Image: Multimeter input terminals on the side of the device.

3.3 Arbitrary Function Generator (AFG) Mode

The AFG function allows you to generate various waveforms with a maximum output frequency of 25MHz.

  1. Connect Output: Connect the AFG output (BNC connector) to the circuit where the signal is needed.
  2. Select AFG Mode: Tap the 'AFG' icon on the main menu.
  3. Select Waveform: Choose from a variety of built-in arbitrary waveforms (e.g., sine, square, triangle).
  4. Adjust Parameters: Set frequency, amplitude, offset, and phase using the touch screen controls. The device supports AM/FM modulation.
Signal generator display showing settings for frequency, amplitude, offset, and phase for a sine wave.

Image: Arbitrary Function Generator display with waveform selection and parameter settings.

Hantek oscilloscope connected to a circuit via the signal generator output.

Image: Example connection for the signal generator function.

3.4 Other Functions

The device also includes a File Browser for managing saved data, a Settings menu for device configuration, and a Pictures viewer.

4. Maintenance

4.1 General Care

  • Keep the device clean and free from dust and moisture. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures or direct sunlight.
  • The anti-fall and shock-resistant design provides durability, but avoid unnecessary drops or impacts.
Hantek oscilloscope with its kickstand extended, showing its robust design.

Image: The device's kickstand and robust casing for protection.

Hantek oscilloscope mounted on a vertical surface using its hanging design.

Image: The unique hanging design for hands-free operation.

4.2 Battery Care

  • For long-term storage, ensure the battery is charged to approximately 50-70% to prolong its lifespan.
  • Avoid completely draining the battery frequently.
  • Use only the provided or approved 18W Type-C charger.

5. Troubleshooting

If you encounter issues with your Hantek TO1000 series oscilloscope, consider the following basic troubleshooting steps:

  • Device not powering on: Ensure the battery is sufficiently charged. Connect the charger and try again.
  • No waveform displayed in OSC mode: Check that probes are correctly connected to both the device and the circuit under test. Verify trigger settings and vertical/horizontal scales are appropriate for the signal.
  • Incorrect multimeter readings: Ensure multimeter probes are correctly inserted into the appropriate terminals for the selected measurement type (e.g., voltage, current, resistance).
  • Touch screen unresponsive: Try restarting the device. If the issue persists, contact customer support.

6. Specifications

6.1 Model Overview

Hantek TO1000 Series Model Comparison
ModelOscilloscope ChannelBandwidthSampling RateStorage DepthSignal Source (AFG)Multimeter
TO1154D4 CH150 MHz1GSa/S8M25MHzYes
TO1204D4 CH200 MHz1GSa/S8M25MHzYes
TO1254D4 CH250 MHz1GSa/S8M25MHzYes
TO11122 CH110 MHz250MSa/S8M--
TO1112C2 CH110 MHz250MSa/S8M-Yes
TO1112D2 CH110 MHz250MSa/S8M25MHzYes
Table comparing Hantek TO1000 series models by oscilloscope channels, bandwidth, sampling rate, storage depth, signal source, and multimeter functionality.

Image: Model comparison table for Hantek TO1000 series.

6.2 Detailed Specifications

Detailed Specifications for TO1000 Series (1G Sampling) and TO1112 Series (250M Sampling)
CategoryTO1000 Series (1G Sampling)TO1112 Series (250M Sampling)
Horizontal Scale Range2ns/div~100s/div (1, 2, 5 sequence)2ns/div~100s/div (1, 2, 5 sequence)
Incremental Time Measurement Accuracy (Full Bandwidth)Single, "Sampling" modeSingle, "Sampling" mode
± (1 sampling interval +100ppm × reading +0.6ns)± (1 sampling interval +100ppm × reading +0.6ns)
>16 times on average>16 times on average
± (1 sampling interval +100ppm × reading +0.4ns)± (1 sampling interval +100ppm × reading +0.4ns)
Sampling intervalseconds/grid ÷200seconds/grid ÷200
Vertical
A/D Converter8-bit resolution, each channel sampled simultaneously8-bit resolution, each channel sampled simultaneously
Vertical Scale Range2mV/div~10V/div at input BNC10mV/div~10V/div at input BNC
Vertical Resolution8bit8bit
Vertical Sensitivity Range2mV/div~10V/div10mV/div~10V/div
Offset Range±1V (2mV/div~100mV/div)±1Vmax (100mV/div)
±10V (200mV/div~1V/div)±10Vmax (1V/div)
±50V (2V/div~10V/div)±50Vmax (10V/div)
Dynamic Range±5div (8bit)±5div (8bit)
Optional Analog Bandwidth Limitation, Typical20MHz, Each channel is independently selectable20MHz, Each channel is independently selectable
DC Gain Accuracy±3% FullScale±3% FullScale
Isolation Between Channels40dB, DC to the maximum rated bandwidth of each model40dB, DC to the maximum rated bandwidth of each model
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Acquisition
Sampling Rate Range1GSa/s250MSa/s
Acquisition ModesNormal, Average, Peak, High resolutionNormal, Average, Peak, High resolution
Waveform Interpolation(sinx)/x(sinx)/x
Detailed specifications table for Hantek TO1000 series, covering horizontal, vertical, and acquisition parameters.

Image: Detailed specifications for Horizontal, Vertical, and Acquisition settings.

Detailed Specifications (Continued)
CategoryTO1000 Series (1G Sampling)TO1112 Series (250M Sampling)
Trigger System
Trigger ModeAuto, Normal, SingleAuto, Normal, Single
Trigger TypeEdge, Pulse Width, Video, Slope, Timeout, Window, Pattern, Interval, Under Runt, UART, LIN, CAN, SPI, IICEdge, Pulse Width, Video, Slope, Timeout, Window, Pattern, Interval, Under Runt, UART, LIN, CAN, SPI, IIC
Measurement
Cursor MeasurementΔV, ΔT, 1/ΔT
Auto MeasurementPeriod, Frequency, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle, Peak-to-Peak, Amplitude, Max, Min, Top, Base, Mean, Cycle Mean, RMS, Cycle RMS, Overshoot, Preshoot, Vmax, Vmin, Vavg, Vrms, Vp-p, Vtop, Vbase, Vmid, Vovs, Vpre, Vfall, Vrise, Vdelay, Vfreq, Vperiod, Vwidth, Vduty, Vphase, Varea, VcycleArea, VpulseCount, VedgeCount, VdelayA->B, VdelayA->B, VphaseA->B, VphaseA->B
Display
Display Type5.0 - 6.9 Inches, 640*480 Pixels
Power Supply
Battery IncludedYes
IS Battery DemountableNo
Environment
OriginMainland China
CertificationCE
High-concerned chemicalNone
Mechanical
Package Dimensions (L x W x H)20cm x 12cm x 6cm
Package Weight1.9 kg
Detailed specifications table for Hantek TO1000 series, covering trigger system, measurement, display, power supply, environment, and mechanical parameters.

Image: Detailed specifications for Trigger, Measurement, Display, Power Supply, Environment, and Mechanical aspects.

7. User Tips

  • Portability: Take advantage of the device's thin body, light weight, and unique hanging design to free your hands during work. It's designed to be easily carried and used on the go.
  • Quick Waveform Capture: Use the one-key waveform storage feature for convenient and quick saving of important measurement data.
  • Universal Charging: The Type-C charging interface is compatible with many mobile phone chargers, allowing you to share charging equipment for convenience.
  • Durability: The anti-fall and shock-resistant corners provide added protection, making the device robust for various working conditions.

8. Warranty and Support

8.1 Warranty Information

This product typically comes with a 1-year after-sales service from the date of purchase. This service covers manufacturing defects and ensures the product is in working order. For specific warranty claims, please refer to your purchase documentation.

8.2 Customer Support

For technical assistance, troubleshooting, or any questions regarding your Hantek TO1000 series oscilloscope, please contact the seller or manufacturer's customer support. Ensure you have your product model and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.