WITRN K2

Rate this product if you’ve used it
Contents

WITRN K2 USB Tester Instruction Manual

Model: K2

1. Introduction

The WITRN K2 is a versatile USB voltage and current meter designed for comprehensive testing of fast charging protocols, power delivery, and cable quality. Featuring a high-speed CPU, a vibrant IPS color screen, and advanced ADC sampling, the K2 provides precise measurements and detailed analysis for various USB-C devices and chargers.

WITRN K2 USB Tester displaying voltage, current, and power
Figure 1: Front view of the WITRN K2 USB Tester, showing real-time voltage, current, and power readings, along with PD3.1 140W indication.

2. Setup and Basic Operation

This section outlines the initial setup and basic functions of your WITRN K2 USB Tester.

2.1 Device Overview

Side view of WITRN K2 USB Tester showing USB HID and NTC ports
Figure 2: Side view of the K2 tester, highlighting the USB HID port for PC connection and the NTC port for external temperature sensing.

The K2 features a 1.54-inch color IPS LCD screen and multiple buttons for navigation. It includes a USB-C male connector for input and a USB-C female port for output, supporting high current direct pass.

2.2 Powering On and Initial Display

  1. Connect the K2's USB-C male connector to a power source (e.g., charger, power bank).
  2. The device should power on automatically, displaying real-time voltage, current, and power readings.
  3. If the screen does not light up, ensure the USB-C data plug is correctly inserted. For the K2 female socket, try flipping it over and plugging it in again.

2.3 Button Functions

Diagram of WITRN K2 interfaces and buttons
Figure 3: Illustration of the K2's interfaces and button layout. Buttons include Back/Exit, Switch/Adjust/Select-, Confirm/Execute/Save/Enter, and Switch/Adjust/Select+.
  • Lightning Button: Activates PD function and turns on the screen.
  • OK Button: Turns on the screen (Note: PD is not supported when turning on with OK button; use the lightning button for PD functions).
  • Navigation Buttons: Used for switching between menus, adjusting settings, and selecting options.

3. Operating Instructions

The K2 offers a range of measurement and detection capabilities.

3.1 Fast Charging Protocol Detection and Decoy

WITRN K2 performing automatic fast charging protocol detection
Figure 4: The K2 displaying detected fast charging protocols from a connected power supply, organized in a new color block arrangement for easy viewing.
  • Connect the K2 between your charger and device.
  • Navigate to the protocol detection menu using the navigation buttons.
  • The K2 will automatically detect and display supported fast charging protocols (e.g., QC, VOOC, PD, FCP, SCP, VIVI, Samsung, MI-PD).
  • The K2 supports PD3.1 with 28V EPR AVS deception, allowing testing of up to 48V/240W outputs.

3.2 E-Marker Data Cable Measurement

WITRN K2 measuring E-Marker data cable information
Figure 5: The K2 connected to a dual-head Type-C data cable, displaying E-Marker chip information such as USB version, power rating, and manufacturer details. A 5V power supply is required for this function.
  • Connect the data cable to be tested to the K2.
  • Ensure a 5V power supply is connected to the K2.
  • The K2 can read chip information from E-Marker cables, supporting Thunderbolt 3/4/5, USB4 EPR, and 50V 5A PD3.1 cables.

3.3 Virtual E-Marker Function

WITRN K2 demonstrating virtual E-Marker function for protocol detection
Figure 6: Comparison of protocol detection with and without the virtual E-Marker function. When enabled, the K2 can detect 100W 5A charging head protocols without needing a physical 5A E-marker data cable.
  • Enable the virtual E-Marker function in the K2's settings.
  • This allows for more convenient detection of charging head protocols, especially for 100W 5A chargers, without requiring a physical 5A E-marker data cable.

3.4 Data Cable Internal Resistance Detection

WITRN K2 displaying data cable internal resistance measurement
Figure 7: The K2 showing internal resistance measurement for a data cable, with quality indicators based on resistance values (G: Good < 80mΩ, A: Acceptable < 120mΩ, M: Moderate < 199mΩ, P: Poor > 200mΩ).
  • Connect the data cable to the K2 and initiate the internal resistance test.
  • The K2 will display the resistance and provide a quality assessment (Good, Acceptable, Moderate, Poor) based on predefined thresholds.

3.5 Battery Capacity and Charge/Discharge Efficiency

WITRN K2 displaying battery capacity and charge/discharge efficiency
Figure 8: The K2 showing calculated charge/discharge efficiency and recorded Wh/mAh capacity, allowing users to assess battery performance.
  • Use the K2 to record Wh capacity during device charging and discharging.
  • The device can convert Wh to mAh and calculate charge/discharge efficiency based on the ratio of discharge to charge capacity.

3.6 Ripple and Spectrum Analysis

WITRN K2 performing high-speed ripple frequency detection and spectrum analysis
Figure 9: The K2 displaying ripple and spectrum curves, used for detecting the output quality and stability of charging heads. Ripple values are categorized as Excellent (<30mV), Normal (30-120mV), High (120-200mV), and Very High (>200mV).
  • Connect a professional commercial load to the K2.
  • The K2 can detect the ripple frequency and spectral characteristics of charging heads and other output devices.
  • This function helps to intuitively assess the output stability and quality of the device.

3.7 PC Connection and Data Logging

WITRN K2 connected to a computer displaying real-time data curves
Figure 10: The K2 connected to a computer via its UID port, showing multi-curve observation of voltage, current, power, and temperature over time, with support for point data query and full-screen display.
  • Connect the K2 to a computer via its USB HID port (Type-C interface). The K2 uses a driver-free HID interface.
  • Use the dedicated PC software (host computer) to observe real-time curves of voltage, current, power, and temperature during charging.
  • The software also supports point data query at any time node and offline data storage.

4. Maintenance

  • Keep the device clean and dry. Avoid exposure to moisture or extreme temperatures.
  • Do not attempt to disassemble the device, as this will void any potential warranty.
  • Clean the screen and casing with a soft, dry cloth. Avoid abrasive cleaners.

5. Troubleshooting

Problem Possible Cause Solution
Screen does not light up. Incorrect USB-C connection or insufficient power. Ensure the USB-C male connector is fully inserted into the power source. If using the K2 female socket, try flipping the connector and plugging it in again. Press the lightning button to activate.
PD spoofing or protocol detection results in black screen/restarts. Device powered on using the OK button, or HID port used for power during protocol testing. Always activate the PD function by pressing the lightning button. Do not connect the HID port for power supply during protocol testing. Repeated restarts during protocol testing are normal.
HID interface connected to computer, but protocol not detected. The HID interface is for PC communication and firmware updates, not protocol detection. Protocol detection is performed by connecting the K2 in-line with the charging path. The HID interface is for PC software interaction and firmware upgrades only.
Inaccurate readings. Poor cable connection, faulty cable, or device malfunction. Ensure all connections are secure. Test with different cables and power sources. If the issue persists, contact support.

6. Specifications

Feature Detail
CPU ARM M4F 240MHz high-speed 32-bit with FPU hardware acceleration unit
Display 1.54-inch color IPS LCD screen, 240 x 240 resolution (wide-angle)
Core ADC 16-bit independent ADC chip (INA226 for 36V, INA237 for 48V models)
Voltage Measurement Range DC 3.3~48V (K2-237), DC 3.3~36V (K2-226)
Voltage Resolution 0.0001V
Current Measurement Range 6A (continuous), 10A (short-term peak, max 2 minutes)
Current Resolution 0.0001A (bidirectional)
Capacity Record 0~99999Ah, 0~99999Wh
High Speed Sampling 2MHz on-chip ADC
Main Interface 24P USB-C male/female socket direct connection
External Sensor NTC-20 ℃~+120 ℃ (TYPE-C interface special temperature probe)
Storage Medium EEPROM wear balance
Firmware Upgrade USB HID (driver-free)
Operating System RTOS + WIUI human-computer interaction system
Dimensions (excluding USB-C male connector) Approx. 36.0 x 33.7 x 9.3 mm
Comparison table of WITRN K2 and other models
Figure 11: Detailed comparison of K2 specifications with other WITRN models (U3, U3LP), highlighting CPU, display, ADC, OS, voltage/current ranges, and supported features.

7. User Tips

  • For PD function activation, always use the lightning button. The OK button only turns on the screen and does not support PD functions, which can lead to issues during protocol detection.
  • If the screen doesn't light up when using the K2 female socket with a Type-C data plug, try reversing the plug.
  • The HID interface is exclusively for connecting to a computer for data logging and firmware updates. It cannot be used for protocol detection or as a power source during protocol testing.
  • It is normal for the K2 to restart multiple times during fast charging protocol detection. This is part of its operational process.
  • While the K2 supports 10A short-term peak current, it is recommended for continuous operation not to exceed 6A to ensure device longevity.

8. Support

For technical assistance or further inquiries, please refer to the manufacturer's official support channels. Keep your unique VIP Code (Serial Number) ready when contacting support.