1. Introduction
The CNC YCQ4-100R 4P Dual Power Automatic Transfer Switch (ATS) is a micro household power switch designed to ensure continuous and reliable power supply. It automatically switches between a main power source and a standby power source (e.g., generator) when an abnormality is detected in the main supply.
This product is specifically designed for domestic track installation and is suitable for PZ30 distribution boxes. It operates on 50 or 60Hz rated 400V AC emergency power supply systems. The ATS features a solid structure, reliable conversion, easy installation, and long operational life. It is widely used in applications where power continuity is critical, offering both automatic and manual operation modes. The ATS is composed of a Transfer Switching Equipment (TSE) and a controller, complying with GB/T14048.11 and IEC60947-6-1 standards for low-voltage switching and control devices.
2. Product Features
- Fast Switching Speed: Achieves switching within 0.008 seconds (8ms) for minimal power interruption.
- Reliable Performance: Engineered for consistent and dependable operation.
- Solid Structure: Durable design for long-term use.
- Easy Installation and Maintenance: Designed for straightforward setup and upkeep.
- Dual Operation Modes: Supports both automatic and manual power transfer.
- Compliance: Meets IEC60947-6-1 and GB/T14048.11 standards.

3. Specifications
| Attribute | Value |
|---|---|
| Model Number | YCQ4-100R/4P |
| Type | Mini Automatic Transfer Switch |
| Poles Number | 4P |
| Rated Current (Ie) | 63A, 100A (selectable) |
| Rated Working Voltage | 220V AC |
| Insulation Voltage (Ui) | 690VAC |
| Impact-resistant Voltage | 8kV |
| Tse Class | PC (Can be manufactured withstood without short circuit current) |
| Frequency | 50/60Hz |
| Standard | IEC60947-6-1 |
| Certification | CE |
| Utilization Category | AC-33iB, AC-31B |
| Weight (4P) | 2.6 kg |
| Electrical Life | 2000 times |
| Manual Operation Life | 5000 times |
| Rated Short Circuit Current (Iq) | 50kA |
| Short Circuit Protection Device (Fuse) | RT16-00-63A |
| Rated Control Voltage (Us) | AC220/50Hz |
| Normal Working Conditions (Control Voltage) | 85-110% Us |
| Auxiliary Circuit | 2 relays, each with two sets of contact converter contact capacity: AC200V/50Hz le=5y |
| Conversion Time of Contactor | < 50ms |
| Operation Conversion Time | < 50ms |
| Return Conversion Time | < 50ms |
| Power Off Time | < 50ms |

4. Safety Information
WARNING: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel.
- Always disconnect power from both main and standby sources before installing or servicing the ATS.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not operate the switch if it appears damaged.
- Verify correct voltage and current ratings before connecting to any power source.
- Keep children and unauthorized personnel away from electrical installations.
5. Installation
The YCQ4-100R/4P ATS is designed for domestic track installation, typically within a PZ30 distribution box.
5.1 Mounting
- Mount the ATS securely onto a standard DIN rail within your distribution box.
- Ensure adequate clearance around the switch for ventilation and access to terminals.

5.2 Wiring Diagram
Refer to the wiring diagram below for proper connection of the main power (Source A), standby power (Source B), control lines, and load output.

Wiring Instructions:
- Source A (City Power) Connection: Connect the main power supply to the terminals labeled 'Source A' (R, S, T, N).
- Source B (Generator) Connection: Connect the standby power supply (e.g., generator) to the terminals labeled 'Source B' (R, S, T, N).
- Load Output: Connect your household load to the 'Load Output' terminals.
- Control Lines:
- Connect the 'Common Control Line' to the appropriate terminals for Source A and Source B.
- Connect the 'Standby Control Line' to the designated terminals for Source B.
- Ensure control wiring for Source A (NO C NC AR AN) and Source B (NO C NC BR BN) are correctly connected as per the diagram.
- Double-check all connections for tightness and correctness before applying power.
6. Operation
The YCQ4-100R/4P ATS offers both automatic and manual operation modes.

6.1 Automatic Mode
- Set the selector switch (red rotary knob) to the "Auto" position.
- In this mode, the ATS will continuously monitor the main power supply (Source A).
- If Source A fails or its voltage drops below acceptable levels, the switch will automatically transfer the load to the standby power supply (Source B).
- Once Source A is restored, the switch will automatically transfer the load back to Source A.
6.2 Manual Mode
- To operate the switch manually, set the selector switch (red rotary knob) to the "Manual" position.
- In manual mode, you can use the rotary knob to switch between Source A and Source B as needed.
- Important Note: Manual operation must be performed carefully. Ensure the switch is in the 'Manual' position before attempting to switch sources manually.
7. Maintenance
The YCQ4-100R/4P ATS is designed for low maintenance. However, regular checks can ensure optimal performance and longevity.
- Visual Inspection: Periodically inspect the switch for any signs of physical damage, loose connections, or overheating (discoloration).
- Terminal Tightness: Ensure all wiring terminals remain tight. Loose connections can cause resistance, heat, and potential failure.
- Dust and Debris: Keep the switch free from dust and debris, which can impede operation or cause overheating. Use a dry, soft cloth or compressed air for cleaning.
- Functional Test: Periodically test the automatic transfer function by simulating a main power failure (if safe to do so and with proper precautions).
- Professional Inspection: For complex issues or annual checks, it is recommended to have the unit inspected by a qualified electrician.
8. Troubleshooting
If you encounter issues with your ATS, consider the following common troubleshooting steps:
- No Power Transfer:
- Check if both main (Source A) and standby (Source B) power supplies are active and within their normal operating voltage range.
- Ensure the selector switch is in the "Auto" position for automatic transfer.
- Verify all control wiring connections are secure and correct according to the wiring diagram.
- Intermittent Operation:
- Inspect all power and control wiring for loose connections.
- Check for stable voltage from both power sources. Fluctuations might cause erratic behavior.
- Overheating:
- Ensure the switch is not overloaded beyond its rated current (63A or 100A).
- Check for proper ventilation around the unit.
- Tighten any loose power connections.
- Manual Operation Failure:
- Ensure the selector switch is firmly in the "Manual" position before attempting to switch sources manually.
- Do not force the rotary knob if it feels stuck; inspect for obstructions.
If the problem persists after these steps, contact qualified technical support.
9. User Tips
No specific user tips were available from reviews or Q&A for this product. Always follow the installation and operation guidelines provided in this manual.
10. Support and Contact
For technical assistance, warranty information, or further inquiries, please contact the manufacturer or your authorized dealer.
- Brand: CNC Electric
- Model: YCQ4-100R/4P
- Manufacturer: CNC Electric Group Co., Ltd.
Please have your product model number and any relevant details ready when contacting support.