1. Introduction
The KONNWEI KW341 is a versatile 6V, 12V, and 24V battery tester designed for cars, motorcycles, and trucks. It provides comprehensive analysis of battery health, cranking performance, and charging system efficiency. This manual will guide you through the setup, operation, and maintenance of your KW341 device.
2. Package Contents
Upon opening your KONNWEI KW341 package, you should find the following items:
- KONNWEI KW341 Battery Tester Unit
- User Manual
- USB Cable (for data printing and software upgrades)
- Color Box Packaging

3. Specifications
The KONNWEI KW341 is built with robust features and specifications to ensure accurate and reliable testing:
- Supported Voltage Systems: 6V, 12V, 24V
- Battery Test Range (CCA): 10-2000
- Supported Battery Standards: CCA, JIS (26A17-245H2), EN, DIN, SAE, IEC, BCI, CA, MCA, GB
- Electric Vehicle Test Range (Ah): 5-220Ah
- Display: 2.8-inch Color Screen
- Material: ABS
- Operating Temperature: -20°C to 70°C (-4°F to 158°F)
- Dimensions: Approximately 16.4 cm (6.46 in) H x 8.6 cm (3.39 in) W x 2.4 cm (0.94 in) D
- Clips: Pure Copper Clips for secure connection
- Interface: USB for data printing and upgrades
- Certifications: CE, FCC, RoHS
- Languages: Supports 12 languages including Chinese, Japanese, Korean, English, German, French, Russian, Spanish, Polish, Italian, Portuguese, Dutch.


4. Setup
The KW341 is designed for ease of use and does not require external power. It draws power directly from the battery under test.
4.1 Connecting the Tester
- Ensure the vehicle's ignition is off.
- Connect the red clamp to the positive (+) terminal of the battery.
- Connect the black clamp to the negative (-) terminal of the battery.
- The device will power on automatically.
Important: The KW341 features built-in reverse polarity protection. If connected incorrectly, the device will not operate, safeguarding both the battery and the tester from damage. Always ensure correct connections for proper functionality.

5. Operating Instructions
The KW341 offers various testing modes to diagnose battery and charging system issues.
5.1 General Navigation
Use the directional buttons (Up, Down, Left, Right) to navigate through the menu options on the 2.8-inch color screen. Press the 'OK' button to confirm a selection and 'ESC' to go back to the previous screen.
5.2 Battery Test
This test evaluates the overall health and charge status of your battery.
- From the main menu, select 'Battery Test'.
- Select the vehicle type (Motorcycle, Car, or Truck).
- Choose the battery location (In-Vehicle or Out-of-Vehicle), battery type (e.g., Regular Flooded, AGM Flat Plate, AGM Spiral, EFB, GEL, Lithium), and the appropriate battery standard (e.g., CCA, JIS, EN).
- Set the battery's rated capacity (e.g., 400A CCA).
- The tester will display the test results, including State of Health (SOH), State of Charge (SOC), Standard (STD) rating, Measured CCA, Voltage (V), and Resistance (R).
- To retrieve a detailed test report, press 'OK' again to generate a QR code. Scan this QR code with your smartphone to view the report.



5.3 Cranking Test
This test analyzes the starting performance of the battery.
- From the main menu, select 'Cranking Test'.
- Follow the on-screen prompts to start the engine.
- The tester will display the cranking time, maximum voltage, and minimum voltage during startup. It will also indicate if cranking is normal or low based on voltage thresholds.
| Battery System | Condition | Voltage |
|---|---|---|
| 12V | Normal | >7.5V |
| 12V | Bad | <7.5V |
| 24V | Normal | >15V |
| 24V | Bad | <15V |

5.4 Charging Test
This test evaluates the vehicle's charging system (alternator, rectifier, etc.).
- From the main menu, select 'Charging Test'.
- Start the engine and increase the RPM as prompted by the device.
- The tester will display loaded voltage, unloaded voltage, and ripple voltage. It will indicate if the charging is normal.

5.5 Waveform Analysis
The KW341 can display real-time voltage waveforms to help identify issues.
- From the main menu, select 'Waveform'.
- The device will display a real-time voltage waveform, allowing you to compare current voltage with minimum and maximum thresholds to identify anomalies.

5.6 Data Printing and Upgrades
The USB interface at the bottom of the machine allows you to plug in a USB cable and upgrade your device on the computer or print test data.
6. Maintenance
To ensure the longevity and optimal performance of your KONNWEI KW341, follow these maintenance guidelines:
- Cleaning: Wipe the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Storage: Store the tester in a dry, cool place away from direct sunlight and extreme temperatures.
- Temperature Range: The device is designed to operate in temperatures from -20°C to 70°C. Avoid prolonged exposure to temperatures outside this range.
- Cable Care: Handle the test cables and clamps with care. Do not pull on the cables to disconnect them.

7. Troubleshooting
If you encounter issues with your KW341, refer to the following common problems and solutions:
- Device does not power on: Ensure the clamps are correctly connected to the battery terminals (red to positive, black to negative). The device draws power directly from the battery. If the battery is completely dead, the tester may not power on.
- Incorrect readings: Double-check that the battery type and CCA rating entered into the device match your battery's specifications. Ensure the clamps have a clean, secure connection to the battery terminals.
- Error messages: Refer to the user manual's specific error code section (if available) or contact customer support.
7.1 Multiple Protections
The KW341 is equipped with several protection features to prevent damage to the device and the battery:
- Reverse Polarity Protection: Prevents damage if clamps are connected incorrectly.
- Over Temperature Protection: Shuts down or warns if the device overheats.
- Short Circuit Protection: Protects against accidental short circuits.
- Over Current Protection: Safeguards against excessive current flow.

8. User Tips
- For the most accurate battery test results, ensure the battery is fully charged and has rested for at least 30 minutes after charging or use.
- Always clean battery terminals before connecting the clamps to ensure good conductivity.
- Utilize the QR code feature to easily save and share test reports for record-keeping or professional consultation.
- Keep the user manual handy for quick reference to specific test procedures and error codes.
9. Warranty and Support
The KONNWEI KW341 comes with a 365-day free replacement warranty. For technical support, warranty claims, or further information, please refer to the contact details provided in your product packaging or visit the official KONNWEI website.