SKE PH21-3.6K

Contents

SKE PH21-3.6K Smart Solar Inverter User Manual

Comprehensive guide for installation, operation, and maintenance of your SKE PH21-3.6K Smart Solar Inverter.

1. Product Overview

The SKE PH21-3.6K Smart Solar Inverter is a versatile off-grid power inverter designed to provide reliable power for various applications. It integrates an MPPT (Maximum Power Point Tracking) solar charger, ensuring efficient energy harvesting from solar panels. This inverter is suitable for both personal computer loads and home appliances, offering a pure sine wave output for sensitive electronics.

Front view of the SKE PH21-3.6K Smart Solar Inverter

Figure 1: Front view of the SKE PH21-3.6K Smart Solar Inverter.

SKE Hybrid Solar Inverter PH21 1.2KW-6.2KW overview with key features

Figure 2: Overview of SKE PH21 Hybrid Solar Inverter series, highlighting key features like Rated Power, Surge Power, Efficiency, and MPPT Solar Charger Type.

2. Safety Information

Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

  • Ensure proper grounding of the inverter.
  • Do not disassemble the inverter. Refer servicing to qualified personnel.
  • Keep away from flammable materials and liquids.
  • Install in a well-ventilated area, away from direct sunlight and heat sources.
  • Ensure all connections are tight and correct before powering on.

3. Package Contents

Upon unpacking, please ensure all items are present and undamaged. If anything is missing or damaged, contact your supplier immediately.

  • SKE PH21-3.6K Smart Solar Inverter Unit
  • User Manual
  • Communication Cables (USB/RS232)
  • Mounting Hardware (if applicable)

4. Product Appearance and Components

Familiarize yourself with the inverter's external features and connection points.

Appearance Instructions with labeled components

Figure 3: Front, side, and bottom views of the inverter with labeled components.

Controls and Indicators:

  1. LCD Display: Shows system status, operating parameters, and error codes.
  2. Status Indicator: LED light indicating the inverter's operational status.
  3. Charging Indicator: LED light indicating battery charging status.
  4. Fault Indicator: LED light illuminating in case of a system fault.
  5. Function Buttons: Used for navigating the LCD menu and setting parameters.
  6. Power On/Off Switch: Main switch to turn the inverter on or off.

Connection Ports:

Rear view of the SKE inverter with connection ports

Figure 4: Rear view showing AC Input, AC Output, PV Input, and Battery Input terminals.

Side view of the SKE inverter with communication port

Figure 5: Side view showing the communication port.

  1. AC Input: Terminal for connecting to the utility grid or a generator.
  2. AC Output: Terminal for connecting to household appliances or other loads.
  3. PV Input: Terminals for connecting solar panels.
  4. Battery Input: Terminals for connecting the battery bank.
  5. Circuit Breaker: Provides overcurrent protection.
  6. USB Communication Port: For data communication with a computer.
  7. RS-232 Communication Port: For data communication with a computer or other devices.

5. Installation

5.1 Mounting the Inverter

Choose a suitable location for mounting the inverter. It should be:

  • Indoors, protected from direct sunlight, rain, and excessive dust.
  • In a well-ventilated area to ensure proper heat dissipation.
  • Mounted vertically on a sturdy surface.
  • Accessible for connections and maintenance.

5.2 Wiring Diagram

The following diagram illustrates a typical system connection for the SKE PH21-3.6K Smart Solar Inverter.

Inverter System Connection Diagram

Figure 6: Inverter System Connection Diagram showing solar panels, inverter, battery, and application loads.

5.3 Connection Steps

  1. Battery Connection: Connect the 24 VDC battery bank to the Battery Input terminals (10). Ensure correct polarity (positive to positive, negative to negative).
  2. Solar Panel Connection: Connect your solar panels to the PV Input terminals (9). Ensure the total PV array open circuit voltage and power are within the inverter's specifications (Max PV Array Open Circuit Voltage: 500V, Max PV Array Power: 4000W, MPP Output Voltage Range: 60-450V).
  3. AC Output Connection: Connect your AC loads (e.g., home appliances, computers) to the AC Output terminals (8).
  4. AC Input Connection (Optional): If using a utility grid or generator as a backup, connect it to the AC Input terminals (7).
  5. Communication Connections: Connect the USB (12) or RS-232 (13) communication cables to a computer for monitoring and configuration, if desired.

Important: Always ensure all power sources are disconnected before making any wiring connections. Double-check all polarities and connections before powering on the system.

6. Operation

6.1 Powering On the Inverter

After completing all connections and verifying their correctness, switch the Power On/Off Switch (6) to the 'ON' position. The inverter will perform a self-test, and the LCD display (1) will light up, showing the current system status.

6.2 LCD Display and Function Buttons

The LCD display provides real-time information about the inverter's operation, including input/output voltage, battery status, charging current, and any fault conditions. Use the Function Buttons (5) to navigate through the display menus and adjust settings as needed. Refer to the on-screen prompts for specific menu options.

6.3 Operating Modes

The inverter features auto-sensing frequency (50Hz/60Hz) and selectable voltage ranges for different applications:

  • For Personal Computers: 170-280VAC input voltage range.
  • For Home Appliances: 90-280VAC input voltage range.

These settings can typically be configured via the LCD display menu.

7. Specifications

Detailed technical specifications for the SKE PH21-3.6K Smart Solar Inverter:

FeatureSpecification (PH21-3.6K)
ModelPH21-3.6K
Rated Power3600W
Input Voltage230 VAC
Selectable Voltage Range170-280VAC (For Personal Computers); 90-280VAC (For Home Appliances)
Frequency Range50 Hz/60 Hz (Auto sensing)
AC Voltage Regulation (Batt. Mode)230VAC±5%
Surge Power6000VA
Inverter Efficiency (Max)93%
Transfer Time10 ms (For Personal Computers); 20 ms (For Home Appliances)
WaveformPure sine wave
Battery Voltage24 VDC
Floating Charge Voltage27 VDC
Overcharge Protection29.2 VDC
Solar Charger TypeMPPT
Maximum PV Array Open Circuit Voltage500V
Maximum PV Array Power4000 W
MPP Output Voltage Range60-450V
Maximum Solar Charge Current80 A
Maximum AC Charge Current80 A
Maximum Charge Current80 A
Humidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature0℃ to 50℃
Storage Temperature-15℃ to 60℃
Dimension (DxWxH)334*309*109 mm
Net Weight8.3 kg
Output Current13A
Output Frequency50Hz/60Hz±0.1Hz
Output TypeSingle Phase
ApplicationSolar Power System Home
ProtectionShort Circuit, Overload, Overvolt
Communication InterfaceUSB/RS232

8. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SKE PH21-3.6K Smart Solar Inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Connections: Annually check all electrical connections (battery, solar panels, AC input/output) for tightness and corrosion. Tighten any loose connections.
  • Environment: Ensure the operating environment remains within the specified temperature and humidity ranges.
  • Battery Health: Monitor your battery bank's health and perform maintenance as recommended by the battery manufacturer.

9. Troubleshooting

If the inverter is not functioning correctly, check the Fault Indicator (4) and the LCD display (1) for error codes. Below are some general troubleshooting tips:

  • No Power Output: Check battery connections, solar panel input, and AC input (if used). Ensure the power switch is ON.
  • Low Power Output: Verify solar panel efficiency, battery charge level, and load requirements.
  • Fault Indicator On: Consult the LCD display for specific error codes and refer to the detailed troubleshooting section in the full manual (if available) or contact support. Common faults include overload, overvoltage, or short circuit.
  • Inverter Overheating: Ensure adequate ventilation around the unit and that the ambient temperature is within the operating range.

10. Warranty and Support

The SKE PH21-3.6K Smart Solar Inverter typically comes with a 12-24 month warranty from the date of delivery. During the warranty period, if a quality problem arises, parts will be provided for free. Beyond the warranty period, assistance and support will still be offered, with spare parts available at cost price.

For technical support, warranty claims, or service inquiries, please contact your original point of purchase or the manufacturer's authorized service center. Provide your model number (PH21-3.6K) and a detailed description of the issue.

11. User Tips

  • Optimize Solar Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to maximize energy harvest.
  • Monitor Battery Health: Regularly check your battery's charge level and overall health to prevent premature degradation and ensure consistent power supply.
  • Load Management: Be mindful of the total power consumption of your connected appliances to avoid overloading the inverter, especially during peak usage.
  • Regular Inspections: Periodically inspect all wiring and connections for any signs of wear, damage, or corrosion to maintain system efficiency and safety.
  • Firmware Updates: If available, keep the inverter's firmware updated to benefit from performance improvements and new features.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.