KKMOON 20A Electronic Load

Contents

KKMOON MDL150 Multifunction Electronic Load User Manual

Model: 20A Electronic Load

1. Introduction

The KKMOON MDL150 is a versatile and high-precision electronic load designed for various testing scenarios. Featuring a 2.4-inch color screen, it supports three sophisticated operation modes: Constant Current (CC), Constant Power (CP), and Constant Resistance (CR). This device provides highly accurate measurements, comprehensive safety protections, efficient cooling, and external temperature measurement capabilities. This manual will guide you through the setup, operation, and maintenance of your MDL150 electronic load.

2. Package Contents

Please verify that all items are present in your package:

  • 1 x MDL150 Electronic Load Unit
  • 1 x Temperature Test Wire
  • 1 x Power Adapter
Electronic load with included accessories: power adapter and temperature test wire.
Figure 2.1: Electronic load with included accessories: power adapter and temperature test wire.

3. Setup Instructions

Follow these steps to set up your MDL150 Electronic Load:

  1. Power Connection: Connect the provided power adapter to the 12VDC input port on the electronic load. Ensure the adapter is plugged into a suitable power outlet.
  2. Load Wiring: The device supports a four-wire system (A+V+V - A -) and is downward compatible with a two-wire system. Connect your load to the appropriate terminals.
  3. External Temperature Sensor (Optional): To measure external temperatures, connect an NTC 3950 10K 1% temperature sensor to the designated NTC sensor port. This allows the device to measure and display temperatures between 0 and 100°C.
Front view of the electronic load with power adapter and temperature sensor connected.
Figure 3.1: Front view of the electronic load with power adapter and temperature sensor connected.

4. Operating Modes

The MDL150 offers three primary operating modes for diverse testing requirements:

  • Constant Current (CC) Mode: Maintains a constant current draw from the power source.
  • Constant Power (CP) Mode: Maintains a constant power dissipation.
  • Constant Resistance (CR) Mode: Maintains a constant resistance value.

You can set and adjust parameters such as overvoltage, overcurrent, and overpower protection values to ensure custom operation within specified limits.

Close-up of the 2.4-inch color screen displaying various parameters and mode settings (Constant Current, Constant Power, Constant Resistance).
Figure 4.1: Display showing Multifunctional Modes & Customization options.

5. Measurement and Calibration

The MDL150 provides highly accurate measurements for voltage, current, and power. It features:

  • Open Calibration: For precise voltage and current readings.
  • Zeroing Load Calibration: Ensures accurate readings and improved reliability over time.
Detailed view of the electronic load's display, highlighting high-precision measurement capabilities and safety protection icons.
Figure 5.1: Display showing High-Precise Measurement & Calibration features.

6. Safety Features

The device incorporates comprehensive safety mechanisms to protect both the unit and the tested components:

  • Overvoltage Protection: Adjustable threshold up to 150V.
  • Overcurrent Protection: Prevents excessive current draw.
  • Overpower Protection: Safeguards against exceeding the maximum power rating.
  • Overtemperature Protection: Triggers when internal temperature exceeds 75°C.
  • Low-Voltage Limit: Adjustable setting to prevent over-discharge.
  • Discharge Time Limit: Supports a maximum of 99 hours and 59 minutes.

7. Cooling and External Temperature Measurement

The MDL150 is equipped with an intelligent cooling system:

  • Efficient Cooling: A programmable fan automatically activates when the internal temperature reaches ≥ 40°C or the current exceeds 3A, ensuring stable operation under heavy loads.
  • External Temperature Measurement: Connect an NTC temperature sensor to measure and display temperatures between 0 and 100°C, adding to its functionality and versatility.
Rear view of the electronic load showing the intelligent cooling fan and external temperature sensor port.
Figure 7.1: Rear view showing the intelligent cooling fan and external temperature measurement port.

8. User Interface and Settings

The 2.4-inch color screen provides a clear and intuitive user experience:

  • Clear Visualization: Displays data and settings clearly.
  • Brightness Adjustment: Customize screen brightness for optimal viewing.
  • Screen Sleep Settings: Configure screen sleep and standby modes.
  • Language Switching: Supports switching between English and Chinese interfaces.
  • Data Management: Ability to reset accumulated data and restore factory settings.
Electronic load in a typical usage environment, emphasizing its user-friendly design and clear 2.4-inch display.
Figure 8.1: User-Friendly Design & Enhanced Usability with 2.4-inch color screen.

9. Maintenance

To ensure the longevity and accuracy of your MDL150 Electronic Load:

  • Regular Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth.
  • Data Reset: Periodically reset accumulated data as needed for new test cycles.
  • Calibration: Utilize the voltage and current open calibration features to maintain measurement accuracy.
  • Factory Reset: If encountering persistent issues or for a fresh start, the device supports restoring factory settings.
  • Storage: Store the device in a dry, cool environment away from direct sunlight and extreme temperatures.

10. Troubleshooting

If you encounter issues with your MDL150 Electronic Load, consider the following:

  • Device Not Powering On: Ensure the 12VDC power adapter is correctly connected and functioning. Check the power outlet.
  • No Load Detected: Verify that the load is correctly wired to the A+V+V - A - terminals. Check for loose connections or damaged wires.
  • Inaccurate Readings: Perform voltage and current open calibration. Ensure no-load zeroing is correctly applied.
  • Over-Protection Triggered: Check the set thresholds for overvoltage, overcurrent, overpower, and overtemperature. Reduce the load or adjust settings if necessary. Ensure adequate cooling.
  • Fan Not Running: The fan activates automatically when the internal temperature reaches ≥ 40°C or current exceeds 3A. If these conditions are met and the fan is still not running, contact support.
  • Screen Issues: Adjust screen brightness. If the screen is unresponsive, try a factory reset.

11. Specifications

FeatureSpecification
NameElectronic Load
MaterialMetal
Working Voltage12VDC
Load Voltage (U)0-150VDC
Load Current (I)0-20A
Load Power (P)0-150W (max. 60W above 120V)
Power FormulaP = U × I ≤ 150W
Wiring MethodA+V+V - A - (four-wire system, compatible with two-wire)
Electricity Metering Upper Limit99999.9Wh
Capacity Measurement Upper Limit99999.9Ah
Accumulated Timing Rangesddd: hh: mm: ss (day: hour: minute: second)
Working ModesConstant Current (CC), Constant Power (CP), Constant Resistance (CR)
Overvoltage ProtectionSupport (adjustable up to 150V)
Overcurrent ProtectionSupport
Overpower ProtectionSupport
Overtemperature ProtectionTriggers when internal temperature exceeds 75℃
Voltage Limited DischargeSupport (defaults to no limit, adjustable)
Limited Time DischargeSupport (max 99 hours 59 minutes)
Cooling MethodProgrammable fan (auto-runs when internal temp ≥ 40℃ or current > 3A)
External Temperature MeasurementConnect NTC 3950 10K 1% sensor (0-100℃)
Interface LanguageChinese/English switching
Accumulated Data ResetSupport
Voltage/Current No-Load ZeroingSupport
Voltage Open CalibrationSupport
Current Open CalibrationSupport
Screen Brightness AdjustmentSupport
Screen Sleep/Standby SettingsSupport
Restore Factory SettingsSupport
Item Size198 * 103 * 85mm / 7.80 * 4.06 * 3.35in
Item Weight933g / 2.06lb
Package Size216 * 110 * 145mm / 8.50 * 4.33 * 5.71in
Package Weight1010g / 2.23lb
Diagram illustrating the dimensions of the electronic load: 198mm (length), 103mm (height), 85mm (width).
Figure 11.1: Dimensions of the MDL150 Electronic Load.
Multiple angled views of the electronic load, showcasing its compact design and various ports.
Figure 11.2: Various views of the MDL150 Electronic Load.

12. User Tips

  • For critical measurements, allow the device to warm up for a few minutes to ensure stable operation.
  • Always double-check your wiring connections before applying power to prevent damage to the electronic load or the device under test.
  • Familiarize yourself with the over-protection settings to prevent accidental shutdowns during testing.
  • Utilize the language switching feature if English is not your preferred interface language.
  • Regularly check the cooling fan for any obstructions to ensure efficient heat dissipation.

13. Warranty and Support

The KKMOON MDL150 Electronic Load is certified with CE, indicating compliance with health, safety, and environmental protection standards for products sold within the European Economic Area.