This manual provides detailed instructions for the installation, operation, and maintenance of your MOES Tuya Access Control System Door Station Intercom (Models TPD01 and TPD02). Please read this manual thoroughly before using the device to ensure correct usage and to prevent damage or injury.
2. Package Contents
Please verify that all the following items are included in your package:

Figure 2.1: Included components for TPD01/TPD02
For Model TPD01 (Surface Mounting):
- Door Station *1
- Rain Hood (Optional) *1
- Rear Cover *1
- Screw Set *1
- Wiring Cover *1
- Sealing Plug of Wiring Port *1
- Junction Pressing Plate *1
- Wrench *1
- Screw Fixing Seat *2
- Manual *1
For Model TPD02 (Flush Mounting):
- Door Station *1
- Mounting Bracket *2
- Decorative Panel *1
- Screw Set *1
- Wiring Cover *1
- Sealing Plug of Wiring Port *1
- Flush Mounting Box *1
- Junction Pressing Plate *1
- Wrench *1
- Screw Fixing Seat *2
- Manual *1
Note: If your package includes a 10.1-Inch Center Control Panel (EU or US version), it will be listed as 'TPD01-10.1-Inch EU' or 'TPD01-10.1-Inch US' kit, which includes the TPD01 kit plus the respective control panel.
3. Product Overview

Figure 3.1: MOES Tuya Door Station Intercom
Front and Back Panel Functions

Figure 3.2: Front and Back Panel Functions
- LED light
- Card reader area
- Call button
- Camera
- Microphone
- Calling indicator light (1st indicator: turns on when call button is pressed)
- Talking indicator light (2nd indicator: turns on when call is picked up or Door Station is monitored)
- Unlocking indicator light (3rd indicator: turns on for 3s when door is opened)
- Phototransistor
- Speaker
Relay Outputs: Supports 2 relay outputs.
4. System Configuration & Diagram
The MOES Tuya Access Control System integrates various components to provide a comprehensive smart intercom and access solution.

Figure 4.1: Access Control System Diagram
4.1 Network (PoE)
The standard RJ45 interface connects the door station with a master station, indoor monitor, or other network equipment via a network switch. The Power over Ethernet (PoE) power supply equipment should comply with IEEE 802.3at (PoE plus), with an output power not less than 30W and output voltage not less than 50V.
4.2 Power
The power interface of the door station connects with 12V DC power.
4.3 Exit/Door-detector/Fire Fighting Linkage
Connect the door station to an exit button, door detector, or fire fighting linkage system as per the wiring diagram on the back panel.
4.4 RS485/Switching Value Output
This interface enables connection to equipment with an RS485 interface. Connect to the lock module (an independent power supply is necessary for the lock).
Wiring Table for RS485/Switching Value Output
| Pin | Function |
|---|---|
| 485+ | RS485 equipment |
| 485- | RS485 equipment |
| NC1 | Normally closed port of relay |
| COM1 | Common port of relay |
| NO1 | Normally open port of relay |
| NC2 | Normally closed port of relay |
| COM2 | Common port of relay |
| NO2 | Normally open port of relay |
Warning:
- When connecting to an inductive load device such as a relay or electromagnetic lock, it is recommended to use a diode 1A/400V (included in the accessories) in anti-parallel with the load device to absorb inductive load voltage peaks. This protects the intercom.
- The load current of the relay cannot be greater than 2A.
4.5 Card Reader Interface
The interface can be connected to one IC/ID card reader or be used for reading information from the built-in card reader. The door station can only be connected to one card reader or management device at a time.
Note: Wiring requires an integrator who knows weak current to operate.
5. Installation
Proper installation is crucial for the optimal performance and longevity of your door station. Follow these guidelines carefully.
5.1 Camera Height Suggestion

Figure 5.1: Recommended Camera Installation Height
For optimal facial recognition and video clarity, the camera should be installed 1450mm to 1550mm (approximately 57 to 61 inches) above the ground. This height allows the camera to capture human faces effectively.
5.2 Mounting Types
The door station supports both surface mounting (TPD01) and flush mounting (TPD02).
5.2.1 TPD01 Surface Mounting (with/without 86/118 Mounting Box)
Follow the diagrams provided in the original manual for detailed steps on surface mounting, including options for using an 86-type or 118-type mounting box and an optional rain hood.

Figure 5.2: TPD01 Surface Mounting Dimensions (168 x 88 x 34 mm)
5.2.2 TPD02 Flush Mounting
For flush mounting, use the provided flush mounting box and decorative panel. The hole-cutting dimension required is 98x199x42mm.

Figure 5.3: TPD02 Flush Mounting Installation
Refer to the original PDF manual for detailed step-by-step diagrams for each mounting type.
6. Basic Operation
6.1 Call and Monitor
6.1.1 Call Indoor Monitor
In standby mode, press the call button on the Door Station to call the Indoor Monitor. Press the button again during a call to end it. If the call fails or the Indoor Monitor is busy, the Door Station will emit a beep sound.
6.1.2 Monitor Door Station
Click the 'Doors' icon on the Indoor Monitor's homepage to monitor the Door Station.

Figure 6.1: Two-way free talk functionality

Figure 6.2: Unlocking through the center control panel
Note: The Door Station and Tuya 10.1-inch center control panel must be in the same Local Area Network (LAN) to function together. The Door Station supports wired network, while the center control panel supports wired or wireless network. This function is available only through the Tuya 10.1-inch center control panel.
6.2 Card Management (Add/Delete Cards by Admin Card)
The system uses an Admin Card to manage other access cards (IC/ID cards).
Video 6.1: Demonstration of adding and deleting access cards using the master card.
6.2.1 Add Other Cards
- Tap the Admin Card once on the card reader area.
- Immediately tap the other cards you wish to add. These cards can now be used to open the door.
- Tap the Admin Card again to finish the adding process.
6.2.2 Delete Other Cards One by One
- Tap the Admin Card twice on the card reader area.
- Immediately tap the other cards you wish to delete. These cards will be removed from the system.
- Tap the Admin Card again to finish the deleting process.
6.2.3 Delete All Other Cards
Tap the Admin Card five times on the card reader area. All other cards (except the Admin Card) will be deleted from the system.

Figure 6.3: Unlocking by IC cards
Tips: The Admin Card is solely for managing other cards and cannot be used to open the door itself.
7. Features
7.1 Clear Night Vision with LED Lights

Figure 7.1: Clear Night Vision
At night, the integrated LED light beads automatically illuminate, providing a clearer image through the 2MP HD camera, ensuring round-the-clock security.
7.2 Tamper Alarm

Figure 7.2: Tamper Alarm
The door station is equipped with a tamper alarm feature to detect unauthorized attempts to remove or damage the unit, enhancing security.
7.3 Applicable Door Lock Types

Figure 7.3: Compatible Door Lock Types
The system is designed to work with a variety of electronic door lock types, offering flexibility for different installation scenarios.
8. Maintenance
8.1 Clean Device Surface
Clean the device surfaces with a soft cloth dipped in some water, and then gently rub the surface with a dry cloth. Do not use chemical products such as diluent, gasoline, alcohol, insect-resist agents, opacifying agent, or insecticide, as these might damage the paint layer or the case.
9. Troubleshooting
- No Power/Device Not Responding: Ensure the power supply (PoE or DC 12V/2A) is correctly connected and providing adequate power. Check all wiring connections.
- Cannot Add/Delete Cards: Ensure you are using the correct Admin Card and following the steps precisely (single tap for add mode, double tap for delete mode, five taps for deleting all cards). Remember the Admin Card cannot open the door.
- Intercom Call Issues: Verify that the Door Station and Indoor Monitor are properly connected to the same LAN. Check network cables and router/switch status.
- Poor Video Quality/Night Vision: Ensure the camera lens is clean and free from obstructions. Check for adequate lighting in night mode (LEDs should activate).
- Abnormal Sound, Smell, or Fume: Immediately unplug the power cord and contact customer service. Do not attempt to repair the device yourself.
- Device Not Working After Long Storage: If the device has not been used for a long time, ensure the adapter and memory card are properly reinserted and the device is powered on correctly.
10. Specifications
| Attribute | Value |
|---|---|
| Model Number | AC-TPD01 |
| Origin | Mainland China |
| Certification | CE |
| System | Linux |
| RAM | 64 MB |
| ROM | 128 MB |
| Front Panel | Aluminum |
| Power Supply | PoE (802.3af) or DC 12V/2A |
| Standby Power | 1.5 W |
| Rated Power | 3.5 W |
| Camera | 2MP, CMOS |
| Indicator Light | 3 |
| Wiegand Port | Support |
| Ethernet Port | 1 x RJ45, 10/100 Mbps adaptive |
| Door Entry | IC (13.56MHz) & ID (125kHz) card |
| Reset Button | 1 |
| RS485 Port | 1 |
| Relay Out | 2 |
| Input | 2 |
| IP / IK Rating | IP65 / IK08 |
| Installation | Surface Mounting |
| Surface Mounting DIM | 168 x 88 x 34 mm |
| Working Temperature | -40℃ to +55℃ |
| Storage Temperature | -40℃ to +70℃ |
| Working Humidity | 10% to 90% (non-condensing) |
11. User Tips
- For optimal performance, ensure your Door Station and any connected indoor control panels are on a stable and reliable network connection.
- Regularly clean the camera lens and card reader area to ensure clear video and reliable card recognition.
- Keep your Admin Card in a secure location, as it is essential for managing other access cards.
- If you experience any issues, always refer to the troubleshooting section before attempting complex solutions.
12. Safety Instructions
To protect yourself, others, and your device from harm, please read the following information before using the device:
12.1 Installation Environment
- Do not install the device in high-temperature or moist environments.
- Avoid areas close to strong magnetic fields (e.g., electric generators, transformers, magnets).
- Do not place the device near heating products (e.g., electric heaters) or fluid containers.
- Do not expose the device to direct sunlight or heat sources, which may cause discoloration or deformation.
- Do not install the device in an unstable position to prevent falling, which could cause property loss or personal injury.
12.2 Guard Against Electric Shock, Fire, and Explosion
- Do not use damaged power cords, plugs, or loose outlets.
- Do not touch the power cord with wet hands or unplug it by pulling the cord.
- Do not bend or damage the power cord.
- Do not touch the device with wet hands.
- Do not allow the power supply to slip or impact the device.
- Do not use a power supply not approved by the manufacturer.
- Prevent liquids, such as water, from entering the device.
12.3 Other Tips
- Do not expose the device to chemical products (diluent, gasoline, alcohol, insect-resist agents, opacifying agent, insecticide) to prevent damage to the paint or case.
- Do not knock on the device with hard objects.
- Do not press the screen surface excessively; overexertion might cause damage.
- Be careful when standing up from the area under the device.
- Do not disassemble, repair, or modify the device without authorization. Unauthorized modifications are not covered under warranty. Contact customer service for repairs.
- If there is abnormal sound, smell, or fume, unplug the power cord immediately and contact customer service.
- When storing the device for a long time, remove the adapter and memory card and store them in a dry environment.
- When moving, provide this manual to the new tenant for proper device usage.
13. FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
14. User Manual (PDF)
A detailed user manual in PDF format is available for download. This document provides comprehensive information and diagrams for advanced configurations and troubleshooting.