1. Introduction
Thank you for choosing the SUNSUN JDP Series DC Water Pump. This intelligent frequency conversion pump is designed for efficient and quiet operation in various aquatic environments, including marine reef aquariums, freshwater aquariums, and ponds. Its DC-24V low voltage design ensures safety, while the intelligent controller allows for precise flow and power adjustments. This manual provides essential information for the safe installation, operation, and maintenance of your JDP water pump.

2. Safety Information
- Always disconnect the power supply before performing any maintenance or installation.
- The pump operates on DC-24V low voltage for enhanced safety. Ensure the power adapter is correctly connected and rated for 100-240V input.
- Do not operate the pump dry. Ensure it is fully submerged in water during operation (for submersible use).
- Keep the power adapter and controller away from water to prevent electrical hazards.
- Regularly inspect the power cord and connections for any damage. Do not use if damaged.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

3. Package Contents
Please check the package to ensure all components are present and undamaged:
- SUNSUN JDP Series Water Pump
- Intelligent Controller (DC-24V)
- Power Adapter (100-240V input)
- Various Outlet Adapters (e.g., 30mm, 40mm, 50mm for JDP-18000; 20mm, 25mm, 30mm, 32mm for JDP-6000; 25mm, 30mm, 32mm, 40mm, 45mm for JDP-10000)
- Wire Connectors

4. Specifications
The JDP series offers various models with different performance characteristics:

For the JDP-18000 model:
- Dimensions: 230 x 120 x 150 mm
- Power: 40 - 160 W
- Lift: 2.8 - 6.8 m
- Flow: 10000 - 18000 L/h
- Power Supply: DC-24V (via 100-240V AC adapter)

General Features:
- Pure copper motor with three-phase brushless and non-inductive drive control technology for long-lasting, stable, and safe operation.
- Efficient mute design ensures quiet operation even at high speeds.
- Removable mesh cover effectively filters foreign matter and prevents small fish from being inhaled.
- Damping foot pads reduce vibration and noise.
5. Setup and Installation
5.1. Component Connection
- Connect the water pump to the intelligent controller using the provided cable. Ensure the connection is secure.
- Connect the power adapter to the intelligent controller.
- Plug the power adapter into a suitable 100-240V AC power outlet.


5.2. Outlet Installation
Select the appropriate outlet adapter (e.g., 30mm, 40mm, 50mm) for your tubing and securely attach it to the pump's outlet.

5.3. Amphibious Use
The JDP pump can be used both submerged and externally (amphibious). For amphibious use, remove the water filter cover and install the appropriate joint directly to the pump's inlet.

6. Operating Instructions
The intelligent controller provides easy adjustment of pump power and features a feeding mode.

- Power On/Off: After connecting the power, press the power button (
) to turn the water pump on or off. If the pump is not used for a long time, it is recommended to turn off the power. - Adjust Pump Power: Tap the "+" or "-" buttons to adjust the pump's power. The controller typically offers 5 speed/power adjustments.
- Feeding Function:
- Press the "||" button once for a 15-minute feeding pause. The 15min indicator light will illuminate.
- Press the "||" button again to enter a 60-minute feeding pause. The 60min indicator light will illuminate.
- During the feeding function, the pump stops running. After 15 or 60 minutes, the pump will automatically resume operation.
- You can also press the "||" button again to manually resume pump operation before the timer expires.

7. Maintenance
- Regular Cleaning: Periodically clean the pump, especially the impeller and the mesh cover, to prevent blockages and maintain optimal performance.
- Mesh Cover: The removable mesh cover should be cleaned regularly to ensure effective filtration and prevent debris buildup.
- Impeller Inspection: Check the impeller for any signs of wear or damage. A damaged impeller can lead to reduced performance or increased noise.
- Damping Foot Pads: Ensure the damping foot pads are intact and properly positioned to continue reducing vibration and noise.
- Always disconnect power before cleaning or performing any maintenance.

8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power supply; Loose connections; Damaged adapter/controller. | Check power outlet; Ensure all cables are securely connected; Inspect adapter and controller for damage. |
| Reduced water flow | Clogged mesh cover or impeller; Blockage in tubing; Pump operating at low power setting. | Clean mesh cover and impeller; Check tubing for obstructions; Increase pump power using the controller. |
| Excessive noise/vibration | Debris in impeller; Worn impeller; Improper seating of pump; Damaged damping foot pads. | Clean impeller; Replace impeller if worn; Ensure pump is securely placed; Check damping foot pads. |
| Pump stops intermittently | Feeding mode activated; Overheating protection. | Check controller for active feeding mode; Ensure adequate water circulation for cooling. |
9. User Tips
No specific user tips were available from provided reviews or Q&A. However, general best practices include:
- Always test the pump in a separate container of water before placing it in your main aquarium or pond.
- Consider the head height and flow rate requirements of your setup when choosing the pump model and power setting.
- For optimal performance and longevity, ensure the pump is not exposed to extreme temperatures or direct sunlight.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.