1. Introduction
This manual provides detailed instructions for the VOTOL EM70 Intelligent Vector Controller, designed for use with PMSM QS120 V3 Mid Drive Motors or 2000W Hub Motors. The controller supports 60V and 72V DC systems, with a peak current of 70A and phase current of 230A, suitable for motors ranging from 1000W to 2500W.
The VOTOL EM70 controller is compatible with QS motors without issue. For other motor brands, parameter adjustments may be required. The controller comes with default functions including Hall Plug, Reverse, Low Brake 0V, Throttle (0-5V), High Brake 12V, Ignition, One-line Wire, Program Port, Three Speed, Sport Mode, Parking, Anti-Theft, Regen Charge, and Flux Weaken Current.
Please note that there are two main settings for the controller: one for mid-drive motors and one for hub motors. Ensure you select the appropriate setting based on your motor type.
Video: A 360-degree view of the VOTOL EM70 controller, showcasing its physical design and various ports.
2. Specifications
| Feature | Specification |
|---|---|
| Model | EM-70 Intelligent Vector Controller |
| Available Battery Voltage | 48V-72V |
| Rated DC Current | 43A |
| Boost DC Current | 70A |
| Peak Phase Current | 230A |
| Max. Power | 4900W |
| MOSFETs Detail | 18 FET |
| Matched Motor Rated Power | 1KW-2.5KW |
| Max. Efficiency | 93% |
| Degree of Waterproof | IP67 |
| Flux Weakening Ratio | 150% |
| Certification | CE, CCC |
| Working Communication | Hall Sensor |
| Net Weight | 1150g |
| Size | 218mm x 124mm x 52mm |
| Programmable | Yes, via PC |
| Origin | Mainland China |
| Speed Signal | One-lin(YXT) & Hall speed signal |

Image: Technical drawing of the VOTOL EM70 controller with dimensions (221mm x 127mm x 53mm).
3. Package Contents
The package includes the following items:
- 1 x EM-70 Controller with Function Harness
- 1 x USB Cable

Image: The VOTOL EM70 controller, function harness, and USB cable included in the package.
4. Setup and Connection
4.1 USB Driver Installation
This section details the installation of the USB driver required for connecting the controller to your computer for programming.
- Download Driver: Download the "USB-to-serial-win 10-20150814" file and decompress it.
- Select Driver: Choose the appropriate driver for your computer. Windows 7 and 10 are supported. iOS and XP systems are not supported. For international PC systems, ensure all Chinese characters are removed from the file name if present.
- Connect USB Cable: After installation, connect the USB cable to the controller and your computer.
- Update Driver (if needed): If the connection fails, right-click "My Computer" on your desktop, then click "Device Manager." Locate "Port (COM & LPT)" and identify the COM port with an exclamation mark (!). Right-click it and select "Update Software." Choose "Browse Computer to find out the drive software." Select "Prolific USB-to-Serial Comm Port Version: 3.3.2.102 [2008/9/24]." Click "Next" to complete the installation.
- Software Preparation (for older versions): For versions prior to 2018.7, copy the
TeeChart5.ocxfile to the root directory of your C: drive. Then, run the setup to register the file (allow installation if prompted by an intercept interface). - Run Software: Launch the
EM_V3 program downloadsoftware.
4.2 Controller Connection
Follow these steps to connect the controller to the programming software:
- Power On: Power on the controller, ensuring the ignition is closed.
- Create File: In the software, click "Creat File."
- Select Port: Click the "researching" button and select the serial port corresponding to your device (usually the last one in the list).
- Open Port: Click "open series port." The device status should display "connected."
- Connect Controller: Turn on the ignition, then click "connect" to the controller. It is recommended to click the "connect" button more than once to ensure a stable connection.
4.3 Bluetooth Connection (Optional)
If using a Bluetooth serial port connection module from VOLT company:
- Connect and power on the Bluetooth module.
- Pair with the Bluetooth serial port from your device list.
- Input the password "1234" to connect.
4.4 Wiring Diagram

Image: Detailed wiring diagram for various functions including Hall Sensor, Ignition, Throttle, High Brake, Speed Signal, Three Speed, Sport, Parking, Low Brake, Reverse, One Click Repair, Program Port, Alarm Power, and Anti-theft Motor Lock.

Image: Pinout diagrams for the 2*8, 2*4, and 2*3 interfaces, detailing the function of each pin (e.g., Ignition, UART-TX/RX, Reverse, Low Speed, GND, Sport, Low Brake, Throttle 5V, Speed, One Click Repair, Parking, One-Line, High Brake, Anti-Theft Power Supply, Anti-Theft Key Ignition, Wheel Signal, Anti-Theft Signal, HALL+, HALL-, HALL Signal A/B/C).
5. Operating Parameters
This section covers various parameter settings available through the programming software. A screenshot of the software interface is provided below for reference.

Image: Screenshot of the VOTOL EM-V3 Software Debugging interface, showing various settings tabs (Setting1, Setting2, Setting3, Display, Port Settings) and basic parameters like Model, Battery Voltage, Overvoltage, Undervoltage, Busbar Current, Phase Current, and external temperature protection settings.
5.1 Battery Voltage Adjustment
The voltage parameter can be freely selected within the hardware support range of the controller. Refer to the table below for recommended settings based on controller model:
| Controller Model | Voltage Range | Current Limit |
|---|---|---|
| EM-30S | 48-72V | ≤35A |
| 84V | ≤30A | |
| EM-50 | 48-72V | ≤50A |
| 84V | ≤55A | |
| 96V | ≤45A | |
| 108V | ≤45A | |
| EM-100 | 48-60V | ≤100A |
| 72V | ≤100A | |
| 96V | ≤100A | |
| EM-150 | 48-60V | ≤150A |
| 72V | ≤180A | |
| 96V | ≤120A |
Warning: Adjusting the voltage parameter without proper hardware support will damage the controller.
5.2 Controller Under-voltage and Soft Under-voltage Adjustment
- Under Voltage Value: This is the threshold for hardware under-voltage protection. Set this based on your battery's under-voltage value.
- Soft Under-voltage: Generally set to the under-voltage value plus 3V.
- Under-voltage Variation: This refers to the range of under-voltage recovery. For example, if overvoltage is 63V and under-voltage variation is 1V, the controller will recover at 64V. This parameter is generally unadjustable.
Note: It is not recommended to change the under-voltage value as it can easily damage the battery and lead to excessive discharge, reducing battery life.
5.3 Controller Battery Current and Phase Current Limited Adjustment
- Busbar Current (A): Set the battery current limit.
- Phase Current: Set the phase current limit.
Warning: Do not set values outside the specified range, as this will damage the controller.
The phase current limited value will restrict the motor's torque output. It is generally not recommended to adjust this from its full power output setting.
5.4 Throttle Voltage Adjustment
- Low Protection Value: Indicates a throttle error.
- Starting Voltage: The voltage at which the motor begins to run.
- End Voltage: The voltage at which the controller considers full throttle reached. It is recommended to set this 0.2V lower than the actual torque voltage.
- High Protection Value: If the voltage exceeds this value, a torque fault will be displayed.
5.5 Start Setting Adjustment (for tricycle gearbox only)
- Starting Torque: Used for gear combination.
- Combined Torque: The lifting force applied after gear clearance is combined.
- Upward Slope: Defines the upward slope of the motor torque.
- Downward Slope: Defines the downward slope of the motor torque.
5.6 Controller and Motor Temperature Protection Function Adjustment
- Start: When the temperature reaches this point, the controller enters temperature protection mode and limits motor torque.
- Over Temperature: At this point, the motor torque output is cut off.
- Recover: When the motor temperature drops below the protection value, you can re-twist the throttle, and the motor will regain power.
- Maximum: The maximum motor temperature is 150°C.
5.7 Parameters Setting for Sports Mode (S gear)
- Current-limiting Value for S gear: When the controller switches to S gear, the battery current increases, providing more power for climbing. Refer to the table in section 5.1 for current limits.
- Flux Weakening Value for S gear: In S gear, the motor enters a flux weakening condition, increasing speed. The range depends on motor characteristics.
| Motor Type | Flux Weakening Value |
|---|---|
| Wheel hub motor, magnet high lower than 35mm | ≤1500 |
| Wheel hub motor, magnet high lower than 50mm | ≤2300 |
| Mid drive motor, surface attached magnetic steel | ≤2300 |
| Mid drive motor, V magnet steel | ≤3000 |
Warning: Setting values outside the specified range can cause motor demagnetization and damage.
- Automatic Logout Enablers: Configure the logout time (e.g., 30 seconds after entering S gear sport mode) and recovery time.
5.8 Downhill Electric Brake Assist (HDC/HHC)
Enable the "HDC Enable" option to activate downhill electric brake assist. Set the minimum speed for the electric brake. If the vehicle speed falls below this minimum, the function will be inactive. A value of 400 typically corresponds to a speed of approximately 15 km/h (this may vary based on motor characteristics).
5.9 Speed Limit Setting
Adjust the controller's speed limit from 0 to 100 percent using the "Speed limited enable" and "Speed" settings.
5.10 Three Gear Setting
- Three Gear Ratio: The range is from 0% to 100%.
- Flux Weakening Adjust: Adjust the middle speed and high speed flux weakening.
- Three Speed Mode: Choose between button or switch control for three gears.
- Soft Start Enable: The soft start function has 16 grades. A lower value results in a softer start.
5.11 Motor Setting
- Motor Pole Pairs: Enter the correct number of motor pole pairs for accurate RPM acquisition.
- Motor Type (Middle Drive Motor): Select the correct motor magnet type for proper motor matching. Note that wheel hub motors are typically surface mount.
- Hall Phase Shift Angle: Adjust the Hall phase shift angle within the range of -180° to 180° for controller and motor phase alignment.
5.12 Speedometer Output
The controller supports two types of speedometer output: single-line speedometer and Hall speedometer. The choice depends on the vehicle's speedometer type. The single-line fixed agreement follows a new standard agreement.
5.13 Moving Assist and Cruising Function
- Move Assist Function: This function is enabled after checking. The speed of the transfer assist is set as a percentage of the motor base speed (default 10%). A moving assist torque value of 320 corresponds to approximately 9-10 N.m (varies by motor characteristics).
- Cruise Function: This function is enabled after checking. To enter cruise control mode, maintain a certain throttle angle for more than 8 seconds. Any operation (e.g., braking, twisting the throttle) will exit cruise mode.
5.14 Dual Voltage Adaptive Function
The controller supports automatic switching between dual voltage modes. Refer to the table below for voltage thresholds:
| Mode | Volt for switching to low volt mode | Volt for switching to high volt mode |
|---|---|---|
| 48-60V | <49V | >63.5V |
| 60-72V | <61V | >77V |
| 72-84V | <72V | >93.5V |
5.15 Reversing, EBS Setting, Low Brake Selection, Starting Safety Switch Function
- Reversing Speed Limit: Adjust the speed limit for reversing (0-100%). Do not exceed 30% to prevent accidents.
- EBS Ratio: Adjust the electronic brake force (0-100%).
- Low Brake Enable: Check to enable low brake functionality. When low brake is used, the original single-branch power-down function becomes a low-level brake.
- Safety Switch Function: Check to enable. When this function is active, you must press the safety switch before starting the vehicle.
6. Controller Status Display
The software provides a real-time display of the controller's working status, allowing you to monitor key parameters and identify potential issues. The display includes:
- RPM: Current motor revolutions per minute.
- Voltage: Current system voltage.
- Current: Current draw.
- Fault Code: Displays any active fault codes.
- Fault Display: Indicates specific fault types such as Hall Fault, Brake, Motor Hall, Undervoltage, Overvoltage, Overcurrent, Controller Failure, Out of Control, Overheating.
- Controller Temp: Internal controller temperature.
- External Temp: External temperature reading.
- Temp Coefficient: Temperature coefficient.
- Indicators: PRNDS, Low/Mid/Hige/Sport, R/P/Brake/ANT/SIDE/Reg/STAND.
6.1 Port Setting Interface
If you are matching with a Hall Type Display, select "IO" and "F", then choose "13: Hall" in the port setting interface.
7. Remote Operation (Software Update and Debugging)
This functionality is intended for software updates, current calibration, and remote operation, and should only be used under the guidance of a company engineer.
7.1 Software Update Procedure
- Click "opening file" in the software.
- Choose the desired ".bin" file for the update.
- Click "download." The file import is successful when the progress shows 100%.
7.2 Troubleshooting Communication Issues
If the controller fails to communicate with the software, you can attempt to re-flash the bottom program using the following steps:
- Close the ignition.
- Open the debugging software (upper computer) and open the serial port. Do not click "connect" yet.
- Open the ignition.
- Open the "CAN. Bin" file.
- The controller should now connect normally.
8. User Tips
- While the VOTOL controller is generally compatible with QS motors, other brands may require manual parameter adjustments for optimal performance.
- Most functional interfaces on the controller require modification and are not plug-and-play. Before making any modifications, carefully review the function lines on your original vehicle and the speedometer's communication signal.
- Assembling electric kits requires technical knowledge. If you lack experience, exercise caution when purchasing and installing, as man-made damage is not covered under warranty.
9. Troubleshooting
- Communication Failure: If the controller cannot communicate with the software, refer to section 7.2 for steps on re-flashing the bottom program. Ensure correct USB driver installation and proper connection of the USB cable.
- Incorrect Operation: Verify all wiring connections against the provided diagrams in section 4.4. Incorrect wiring can lead to malfunctions or damage.
- Fault Codes: If the controller displays a fault code, check the "Controller Status Display" section (Section 6) for potential causes and indicators.
- Controller Damage: Always ensure that voltage and current parameters are adjusted within the specified ranges to prevent damage to the controller or connected components. Refer to sections 5.1, 5.2, 5.3, 5.7 for parameter limits.
10. Support
For comprehensive instructions, advanced settings, and detailed diagrams, please refer to the official user manual in PDF format. You can access the PDF manual here.
For further assistance or technical support, please contact your vendor or refer to the official VOTOL support channels.