WITRN CC1 USB Voltage Current Meter Tester

Model: CC1 (Red Version)

Introduction

The WITRN CC1 is a compact yet powerful USB Voltage Current Meter Tester designed for precise measurement and monitoring of power delivery through Type-C connections. Featuring a digital color screen, it supports PD3.1 standards, allowing for voltage measurements up to 28V and peak currents of 10A. This device is ideal for testing chargers, cables, and devices to ensure optimal performance and diagnose potential issues.

WITRN CC1 USB Meter (Red Version)

Figure 1: WITRN CC1 USB Meter (Red Version)

Product Overview

The CC1 meter integrates advanced technology to provide comprehensive power monitoring capabilities. Its key features include:

  • High-Precision Measurement: Equipped with a 16-bit independent ADC (INA226) for accurate bidirectional current sampling.
  • Wide Compatibility: Supports PD3.1, PD2.0/3.0 QC4+ PPS, QC2.0/3.0/QC3+, AFC/FCP, and various domestic fast charging protocols.
  • Real-time Digital Display: A clear color screen shows voltage (U), current (I), and power (P) simultaneously.
  • Data Recording: Features an independent electronic hard disk (EEPROM) for offline storage of capacity records, including maximum, minimum, and average values during charging sessions.
  • High Voltage Passthrough: Built-in DC-DC step-down circuit ensures safe and direct passthrough of PD3.1 28V high voltage.
  • Cable Detection: Supports EPR/E-Marker cable detection and Emark cable detection.
WITRN CC1 Displaying Voltage, Current, Power

Figure 2: Real-time display of Voltage, Current, and Power

WITRN CC1 Data Recording Features (Max/Avg)

Figure 3: Data recording showing Max and Average values

Specifications (Model CC1)

Below are the detailed technical specifications for the WITRN CC1 USB Voltage Current Meter Tester:

WITRN USB Meter Model Comparison Table

Figure 4: WITRN USB Meter Model Comparison Table (CC1 column details)

Feature Specification (CC1)
CPURiscV 32bit
Screen Size0.96 inch full view
Resolution160*80 IPS
Operating SystemSingle task
UI ElementSolid font
Voltage RangePD3.1 4-36V
Current Range0-10A (Max)
StorageEEPROM
Main InterfacePD3.1 24P public (Type-C)
Auxiliary InterfaceType-C 24P public
HID Independent DiskYes
ADC ChipTI 16-bit high precision
Voltage/Current Resolution0.0001A/0.0001V
Upper Computer Software SupportNo
BluetoothNo
Fast Charge TriggerPD3.1 EPR 48V
EPR/E-Marker Cable DetectionYes
PD Protocol MonitoringSimple monitoring
QC2.0/3.0/QC3+Detect + Trigger
AFC/FCPDetect + Trigger
PD2.0/3.0 QC4+ PPSDetect + Trigger
V'/V0 F1*nChargeDetect + Trigger
Domestic Fast Charge1.0+2.0
V*C1.0+2.0
MTK PE1.1/2.0Detect
MI A/C 120WDirect pass, no trigger
MI A/C 120W ReverseDirect pass, no trigger
Built-in DC-DCYes
Protocol Monitoring Switch1 group
High Speed Waveform600KHz
Line Resistance MeasurementExternal adapter (e.g., UL004 Kelvin test kit)
Emark Cable DetectionYes
Package Dimensions (L x W x H)23 cm x 17 cm x 2 cm
Package Weight0.047 kg

Setup Instructions

Follow these steps to set up your WITRN CC1 USB Meter:

  1. Connect to Power Source: Insert the male Type-C connector of the WITRN CC1 into a compatible Type-C power adapter or power bank.
  2. Connect Device: Plug the Type-C charging cable of the device you wish to test (e.g., smartphone, laptop) into the female Type-C port on the WITRN CC1.
  3. Power On: The meter will automatically power on and display real-time voltage, current, and power readings once a connection is established and power flows through.

Operating Instructions

The WITRN CC1 is designed for straightforward operation:

Real-time Monitoring

Upon successful connection, the meter's color screen will immediately display the following parameters:

  • U (Voltage): The current voltage being supplied.
  • I (Current): The current draw of the connected device.
  • P (Power): The calculated power (Voltage x Current).

Data Recording and Analysis

The CC1 can record charging data for later review:

  • The device automatically records capacity data.
  • It can store maximum (MAX), minimum (MIN), and average (AVG) values for voltage, current, and power during a charging session.
  • Specific instructions for navigating recorded data or resetting values are typically handled via the two small buttons on the side of the device. Refer to the on-screen prompts for navigation.

Cable Resistance Measurement (with external adapter)

For advanced users, the CC1 can be used with an external adapter, such as the UL004 Kelvin test kit, to precisely measure the internal resistance of data cables. This helps in identifying high-quality cables that minimize power loss.

WITRN CC1 with UL004 Kelvin Test Kit for Cable Resistance

Figure 5: Cable resistance testing setup with UL004 Kelvin Test Kit

Maintenance

To ensure the longevity and accuracy of your WITRN CC1 USB Meter, please follow these maintenance guidelines:

  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Cleaning: Use a soft, dry, lint-free cloth to clean the screen and body. Avoid using abrasive cleaners or solvents.
  • Handling: Handle the device with care to prevent physical damage. Avoid dropping or subjecting it to strong impacts.
  • Connectivity: Ensure Type-C connectors are clean and free of debris before plugging them in to prevent poor contact or damage.

Troubleshooting

If you encounter issues with your WITRN CC1, refer to the following common problems and solutions:

Problem Possible Cause Solution
No display or device not powering on. No power from source, loose connection, or faulty cable. Ensure the power source is active. Check all Type-C connections for tightness. Try a different cable or power source.
Inaccurate or fluctuating readings. Poor quality cable, unstable power source, or high resistance in the connection. Use a known good quality Type-C cable. Ensure the power source is stable. Check for any physical damage to connectors.
Connected device not charging or charging slowly. Meter interference (unlikely), faulty cable, or incompatible fast charge protocol. Bypass the meter and connect the device directly to the charger to isolate the issue. Ensure your charger and device support the same fast charging protocols.
Data recording not working. Memory full or specific recording mode not activated. Check the device's on-screen menu for options to clear data or activate recording.

User Tips

  • Cable Quality Matters: For the most accurate readings and efficient charging, always use high-quality, certified Type-C cables. The CC1 can help you identify poor cables when used with a Kelvin test kit.
  • Monitor Over Time: Use the data recording feature to track charging behavior over an extended period. This can help identify intermittent issues with chargers, cables, or the device being charged.
  • Understand Fast Charging: Familiarize yourself with the fast charging protocols supported by your devices and chargers. The CC1 can help confirm if the correct protocol is being negotiated.
  • Environmental Factors: Extreme temperatures can affect battery charging and meter accuracy. Operate the meter within typical room temperatures for best results.

Warranty and Support

The WITRN CC1 USB Voltage Current Meter Tester is manufactured in Mainland China. For any technical support, warranty claims, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?