TTNergy MPS-V MAX

Contents

TTNergy Hybrid Solar Inverter User Manual

Models: MPS-V MAX 7.2KW, MPS-V MAX 8.2KW, MPS-V MAX 10.2KW

1. Introduction

This manual provides essential information for the safe and efficient operation of your TTNergy MPS-V MAX series hybrid solar inverter. The MPS-V MAX series combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings and easy access to operational data.

The inverter is designed for both on-grid and off-grid applications, offering flexibility for various solar power system setups. It supports dual output and includes advanced features like a built-in anti-dust kit and smart battery charge design.

2. Key Features

  • Pure sine wave output.
  • Output power factor 1.0.
  • WIFI & GPRS connectivity for iOS and Android monitoring.
  • Capable of running without a battery.
  • One-click restoration to factory settings.
  • Built-in Lithium battery automatic activation.
  • High PV input voltage range (90~500VDC).
  • Built-in anti-dust kit for harsh environments.
  • Smart battery charge design to optimize battery life.
  • Dual output capability.
  • Intuitive touch button interface.
  • Built-in 160A (for 7.2KW/8.2KW models) or 180A (for 10.2KW model) MPPT solar charger.
Overview of TTNergy Hybrid Solar Inverter features including RGB lights, MPPT charging, LCD display, and WiFi/GPRS connectivity.
Figure 2.1: Overview of Inverter Features

3. Setup and Installation

Proper installation is crucial for the safety and performance of your inverter. It is recommended that installation be performed by a qualified professional.

3.1 Basic System Architecture

The inverter integrates into a solar power system that can include solar panels, a utility grid connection, a generator, a battery bank, and various home loads. The system can be monitored via a cloud platform, web interface, or mobile application.

Diagram showing the basic system architecture of the hybrid solar inverter connected to solar panels, utility grid, generator, battery, and home loads, with monitoring via WiFi/GPRS module.
Figure 3.1: Basic System Architecture

3.2 Connection Ports

The rear panel of the inverter provides all necessary connection points for AC input, main AC output, secondary AC output, PV inputs, battery connections, and communication ports.

Rear panel of the inverter showing connection terminals for AC IN (L, N, Ground), MAIN OUT (L, N), SECOND OUT (L, N), PV1+ and PV1-, PV2+ and PV2-, COMM port (Ethernet), and POS+ and NEG- for battery connections.
Figure 3.2: Rear Panel Connections
  • AC IN: Connect to the utility grid or generator.
  • MAIN OUT: Primary AC output for critical loads.
  • SECOND OUT: Secondary AC output for non-critical loads (available in battery mode).
  • PV1+, PV1-, PV2+, PV2-: Connect to solar panel arrays. The inverter features dual MPPT inputs.
  • COMM: Ethernet port for communication, including WiFi/GPRS module connection.
  • POS+, NEG-: Connect to the battery bank.

3.3 System Operation Diagrams

The inverter supports various operational modes depending on whether a battery is connected and the availability of solar power, utility, or generator input. The diagrams below illustrate typical setups.

System diagrams illustrating operation without battery connected (solar power, generator, or utility directly powering home appliances) and operation with battery connected (solar power, generator, or utility charging battery and powering home appliances).
Figure 3.3: System Operation with and without Battery

4. Operating Instructions

4.1 LCD Display and Controls

The inverter is equipped with an LCD display and touch buttons for monitoring and configuration. The display provides real-time information on power generation, consumption, battery status, and more.

Close-up of the inverter's LCD display showing various power flow indicators, voltage, current, frequency, and energy readings.
Figure 4.1: LCD Display Interface

Use the touch buttons (typically Up, Down, Enter, and Escape/Menu) to navigate through the display menus and adjust settings such as battery charging current, AC/solar charger priority, and acceptable input voltage range.

4.2 RGB Lighting Modes

The inverter features RGB lighting that indicates its current working mode:

  • Red: Battery mode (inverter is drawing power from the battery).
  • Blue: Utility mode (inverter is drawing power from the utility grid).
  • Purple: PV mode (inverter is primarily drawing power from solar panels).
Three inverters showing different RGB light colors: Purple for PV Mode, Red for Battery Mode, and Blue for Utility Mode.
Figure 4.2: RGB Lighting for Working Modes

4.3 Remote Monitoring

The inverter supports remote monitoring via a WiFi/GPRS module, allowing you to track system performance and status from your iOS or Android device using a dedicated mobile application.

Diagram showing the inverter connected to a WiFi/GPRS module, which then connects to the internet for monitoring via a web interface or a mobile app on a smartphone.
Figure 4.3: Remote Monitoring via Mobile App

4.4 Product Overview Video

Video 4.1: A brief overview of the TTNergy Hybrid Solar Inverter, showcasing its design, LCD display, and connection ports.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.

  • Visual Inspection: Periodically inspect the inverter for any signs of damage, loose connections, or corrosion.
  • Cleanliness: Keep the inverter's ventilation openings clear of dust and debris. The built-in anti-dust kit helps in reducing dust accumulation in harsh environments, but regular cleaning of external surfaces is still recommended.
  • Battery Health: The smart battery charge design helps optimize battery life. However, it is advisable to monitor battery performance and follow the battery manufacturer's maintenance guidelines.
  • Firmware Updates: Check for any available firmware updates through the monitoring application or manufacturer's website to ensure your inverter has the latest features and bug fixes.

6. Troubleshooting

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For detailed error codes and specific solutions, please consult the full product manual or contact technical support.

  • No Power Output: Check all AC and DC connections. Ensure solar panels are receiving adequate sunlight and batteries are charged. Verify circuit breakers are not tripped.
  • Inverter Not Turning On: Confirm battery connections are secure and battery voltage is within the acceptable range. Check the main power switch.
  • Error Codes on LCD: Note down any error codes displayed on the LCD and refer to the detailed manual for their meaning and recommended actions.
  • Communication Issues: Ensure the WiFi/GPRS module is correctly installed and connected. Check network connectivity and router settings.

7. Specifications

Feature MPS-V MAX 7.2KW MPS-V MAX 8.2KW MPS-V MAX 10.2KW
Phase1-phase
Maximum PV Input Power7200W8200W10200W
Rated Output Power7200W/7200VA8200W/8200VA10200W/10200VA
Maximum Solar Charging Current160A160A180A
GRID-TIE OPERATION - PV Input (DC)
Nominal DC Voltage/Maximum DC Voltage360VDC/500VDC
Start-up Voltage/Initial Feeding Voltage90VDC/120VDC
MPPT Voltage Range90VDC~450VDC
Number of MPPT Trackers/Maximum Input Current1/27A
GRID-TIE OPERATION - Grid Output (AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range195.5~253VAC
Nominal Output Current31.3A35.6A44.3A
Power Factor>0.99
Feed-in Grid Frequency Range49~51±1Hz
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)98%
TWO LOAD OUTPUT POWER
Full Load7200W8200W10200W
Maximum Main Load7200W8200W10200W
Maximum Second Load (battery mode)2400W2733W3400W
Main Load Cut Off Voltage44VDC
Main Load Return Voltage48VDC
OFF-GRID OPERATION - AC Input
AC Start-up Voltage/Auto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC or 170-280VAC
Maximum AC Input Current40A40A50A
Nominal operating frequency50/60Hz
Surge power14400W16400W20400W
OFF-GRID OPERATION - PV Input (DC)
Maximum DC Voltage500VDC
MPPT Voltage Range90VDC~450VDC
Number of MPPT Trackers/Maximum Input Current1/27A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage48VDC
Output WaveformPure sine wave
Efficiency (DC to AC)94%
BATTERY & CHARGER
Nominal DC Voltage48VDC
Maximum Solar Charging Current160A160A180A
Maximum AC Charging Current140A140A160A
Dimensions (H x W x D)468 x 295 x 140 mm
Weight14.5 kg

8. User Tips

  • Battery Capacity Matching: The correct matching of battery capacity is crucial. It should be determined based on the specific usage requirements of your loads and application scenarios. Incorrect sizing can lead to insufficient power or wasted generation. Refer to the detailed manual or consult technical support for recommendations.
  • Environmental Considerations: While the inverter has a built-in anti-dust kit, ensure it is installed in a well-ventilated area to prevent overheating and maintain optimal performance.

9. Warranty and Support

9.1 Warranty Period

This TTNergy Hybrid Solar Inverter comes with a twelve (12) month warranty period from the date of purchase.

9.2 Technical Support

For technical assistance, troubleshooting, or any inquiries regarding your inverter, please contact TTNergy support. You may reach Felix from China for product information or support at WHATS +86 13786139874.

© 2024 TTNergy. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.