TZONE RD07-4G

Rate this product if you’ve used it
Contents

TZONE RD07-4G LoRa Gateway and Sensor Temperature Humidity Controller User Manual

Model: RD07-4G

1. Product Overview

The TZONE RD07-4G LoRa Gateway is a robust industrial IoT device designed for comprehensive temperature and humidity monitoring solutions. It acts as a central hub, collecting data from various LoRa sensors and transmitting it via 4G to a cloud platform for real-time monitoring, data analysis, and alarm notifications. This gateway supports a wide range of applications, from smart buildings and homes to industrial environments requiring precise environmental control.

Front view of the TZONE RD07-4G LoRa Gateway with two antennas connected.

Figure 1: Front view of the TZONE RD07-4G LoRa Gateway with two antennas connected. The front panel shows Power, NET, and RF indicator lights.

Side view of the TZONE RD07-4G LoRa Gateway, highlighting the heat sink fins and antenna connections.

Figure 2: Side view of the TZONE RD07-4G LoRa Gateway, highlighting the heat sink fins and antenna connections.

TZONE RD07-4G LoRa Gateway alongside two types of LoRa temperature and humidity sensors.

Figure 3: TZONE RD07-4G LoRa Gateway shown with compatible LoRa temperature and humidity sensors.

2. Specifications

Attribute Value
Product Name TZONE IOT Device 4G LoRa Gateway And Sensors Temperature Humidity Controller
Model Number RD07 4G
Modulation LoRa
Interface 4G/RS485/Modbus - RTU
RF Frequency 433/470/868/915MHz (optional)
Working Temperature Condition -20°C ~ +60°C
Working Humidity Condition 5%RH ~ 95%RH (non-condensing)
Maximum Range in Open Area 5KM
Inner Lithium Battery Built-in 3.7V/850mAh (rechargeable)
Power Supply DC12V
Transmit Interval 10sec ~ 6000sec (user definable)
Sensitivity of Receiving -148dBm
Low Voltage Alarm Yes (user definable)
Temperature Alarm Yes (user definable)

Key Features:

  • Adopting latest 4G technology for reliable data transmission.
  • Maximum 5km long distance measurement in open areas for LoRa sensors.
  • Backup battery for emergency use, ensuring continuous operation.
  • Capable of recognizing up to 100 sensor tags simultaneously.
  • Easy configuration via USB or SMS.

3. Setup Guide

Follow these steps to set up your TZONE RD07-4G LoRa Gateway:

  1. Mounting: Securely mount the gateway in a suitable location, preferably central to your LoRa sensors and with good 4G signal reception. The device features mounting brackets for easy installation.
  2. Antenna Connection: Connect the provided antennas to the RF ports on the gateway. Ensure they are tightened securely to optimize signal strength.
  3. Power Connection: Connect the DC12V power supply to the designated power input terminal on the gateway. The terminal block also includes GND connections.
    Close-up of the TZONE RD07-4G LoRa Gateway's terminal block, showing connections for RS485-B, RS485-A, GND, OUTPUT, GND, and 12V power input.

    Figure 4: Terminal block connections for RS485, Output, and 12V power.

  4. Sensor Connection (Optional): If using RS485/Modbus-RTU sensors, connect them to the RS485-A and RS485-B terminals. Ensure correct polarity.
  5. SIM Card Installation: Insert a valid 4G SIM card into the designated slot (if applicable and not pre-installed). Ensure the SIM card is active and has data services.
  6. Initial Configuration: The gateway can be configured via USB or SMS. Refer to the detailed configuration guide for setting up network parameters, LoRa sensor pairing, data transmission intervals (10sec to 6000sec), and alarm thresholds (low voltage, temperature).
  7. System Overview: The system operates by LoRa sensors transmitting data wirelessly to the gateway, which then uses its 4G connectivity to send this data to a cloud platform. Users can access data and receive email alarms from the cloud.
    Diagram illustrating the data flow: LoRa Sensors transmit data to the LoRa Gateway, which then sends it via 4G to a cloud platform for data viewing and email alarms.

    Figure 5: Data flow diagram from LoRa sensors to cloud platform.

4. Operating Instructions

Once the gateway is set up and configured, it will automatically begin collecting data from paired LoRa sensors and transmitting it to the cloud platform. The Power, NET, and RF indicator lights on the front panel provide status information:

  • Power LED: Indicates power status. (Typically solid green when powered on).
  • NET LED: Indicates 4G network connectivity status. (Refer to specific LED patterns in the full manual for detailed status).
  • RF LED: Indicates LoRa radio frequency activity. (Flashes when receiving data from sensors).

Data can be accessed and visualized through the dedicated cloud platform. Alarm notifications (e.g., for temperature excursions or low battery voltage) will be sent via email as configured during setup.

Applications:

The TZONE RD07-4G LoRa Gateway is suitable for a variety of temperature monitoring applications, including:

  • Cold Rooms
  • Fruits and Vegetables Refrigeration
  • Refrigerated Storage of Food
  • Cold Medicine Storage
  • General Warehouse Monitoring
Application diagram showing the LoRa temperature monitoring solution used in various environments like cold rooms, refrigerated warehouses for fruits/vegetables, medical fridges, and cold medicine storage.

Figure 6: Typical application scenarios for the LoRa temperature monitoring solution.

5. Maintenance

To ensure optimal performance and longevity of your RD07-4G LoRa Gateway, consider the following maintenance guidelines:

  • Cleaning: Periodically clean the exterior of the device with a soft, dry cloth. Avoid using harsh chemicals or abrasive materials.
  • Connection Check: Regularly inspect all cable connections (power, antennas, RS485) to ensure they are secure and free from damage.
  • Battery Health: The gateway has a built-in rechargeable 3.7V/850mAh lithium battery. Ensure the device is connected to its DC12V power supply to keep the battery charged. The battery acts as a backup during power outages.
  • Firmware Updates: Check the manufacturer's website periodically for any available firmware updates. Follow the provided instructions carefully for any update procedures.
  • Environmental Conditions: Ensure the gateway operates within its specified working temperature (-20°C ~ +60°C) and humidity (5%RH ~ 95%RH non-condensing) conditions.

6. Troubleshooting

If you encounter issues with your RD07-4G LoRa Gateway, refer to the following common troubleshooting steps:

  • No Power:
    • Check if the DC12V power adapter is correctly connected and receiving power.
    • Verify the power cable is not damaged.
    • Ensure the Power LED is illuminated.
  • No 4G Network Connectivity (NET LED off or flashing incorrectly):
    • Ensure the 4G antennas are securely attached.
    • Check if the SIM card is correctly inserted and active with a data plan.
    • Verify 4G signal strength in the installation location. Try relocating the gateway if signal is weak.
    • Confirm 4G network settings are correctly configured via USB/SMS.
  • No LoRa Sensor Data (RF LED not flashing or no data on platform):
    • Ensure LoRa antennas are securely attached.
    • Verify LoRa sensors are powered on and within the 5KM open area range of the gateway.
    • Check if LoRa sensors are correctly paired and configured with the gateway.
    • Confirm the RF Frequency setting matches your sensors.
  • Incorrect Readings or Alarms:
    • Verify sensor calibration if possible.
    • Check configured alarm thresholds (low voltage, temperature) on the platform or via configuration.
    • Ensure sensors are placed in appropriate locations for accurate readings.
  • Configuration Issues:
    • Double-check all parameters entered during USB/SMS configuration.
    • Ensure the correct software/tool is used for USB configuration.

7. Warranty and Support

The TZONE RD07-4G LoRa Gateway comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use. For technical support, troubleshooting assistance, or warranty claims, please contact your vendor or the manufacturer's customer service. Please have your model number (RD07-4G) and purchase details ready when contacting support.

The product also supports OEM and ODM customization, indicating flexibility for specific project requirements.

8. User Tips

While no specific user reviews or Q&A were provided, general tips for using IoT gateways and sensors include:

  • Optimal Placement: For best LoRa range, place the gateway in an elevated position, away from large metal objects or thick walls that can obstruct signals.
  • Antenna Orientation: Experiment with antenna orientation to achieve the best signal reception for both LoRa and 4G networks.
  • Regular Monitoring: Regularly check the cloud platform for data consistency and system health to proactively identify any potential issues.
  • Security: Ensure your cloud platform account is secured with strong passwords and two-factor authentication if available.

© 2023 TZONE. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?