1. Introduction
The SYMIK Intelligent Charging Case & Power Bank Converter is a versatile accessory designed specifically for Insta360 X4 Air batteries. It functions as a multi-mode charger, power bank, and storage solution, featuring a high-definition LCD screen for detailed information and customizable settings.
Note: The charger is a SYMIK brand, and the battery is an original Insta360 X4 Air battery.

Figure 1.1: SYMIK Hub and two Insta360 X4 Air Batteries
2. Product Overview
The SYMIK Intelligent Charging Case offers advanced features for managing your Insta360 X4 Air batteries.

Figure 2.1: Key Features of the SYMIK Intelligent Charging Case
Key Features:
- Multi-Modes: Charger, Power Bank, Accumulation, Even Out.
- Fast Charging: Simultaneously charges two batteries.
- 1.47" LCD Screen: High-definition color screen displays detailed battery and charging information.
- 27W Total Power: Efficient power delivery.
- 12+ Options Settings Menu: Customizable parameters for advanced users.
- MicroSD Card Storage: Stores two MicroSD cards.
- Magnetic Flip Design: Secure closure for battery and card storage.
- Adjustable Charging Parameters: Fine-tune charging settings.
- Screen Wake-up: Screen can be activated without external power supply.

Figure 2.2: Intelligent Display and Hardcore Technology Modes
Hardcore Technology 5 Modes:
- Charger Mode: Standard battery charging.
- Power Bank Mode*: Discharges X4 Air batteries for output power to charge other devices. *This case itself does not have internal batteries.
- Accumulation Mode: Combines two partially charged batteries into one fully charged battery, eliminating mid-use battery swaps.
- Even Out Mode: Equalizes the State of Charge (SOC) across batteries for optimal storage and extended lifespan.
- Settings Mode: Access and customize device parameters.

Figure 2.3: Accumulation Mode and Even Out Mode Explained
3. Setup
3.1. Inserting Batteries and MicroSD Cards
The charging case features dedicated slots for two Insta360 X4 Air batteries and two MicroSD cards.
- Open the magnetic flip cover.
- Insert Insta360 X4 Air batteries into the battery slots, ensuring correct orientation.
- Insert MicroSD cards into the designated slots. Press to lock, press again to eject.

Figure 3.1: MicroSD Card Insertion and Ejection
3.2. Initial Charging
To charge the batteries within the SYMIK case:
- Connect the SYMIK charging case to a power source using a USB-C cable.
- The 1.47" LCD screen will display charging status, including voltage, wattage, and battery percentages.
- The green indicator light will be solid when charging is complete.

Figure 3.2: Bi-directional Charging Capability
Charging Time (with 9V/2A adapter):
- 0% to 80%: Approximately 35 minutes @ 12W
- 0% to 100%: Approximately 50 minutes @ 12W
For optimal fast charging, ensure you use a compatible 9V/2A (27W Max) USB-C power adapter.
4. Operation
4.1. Screen and Button Functions
The SYMIK charging case features a 1.47" LCD screen and a push button for interaction.

Figure 4.1: Waking Up the Screen Display
- Wake-up: The screen can be woken up by opening the lid, pressing the button, or inserting a battery.
- Navigation: Use the push button to navigate through menus and confirm selections.
- Real-time Display: The screen displays real-time battery power (charge/discharge), voltage, current, cycle counts, and cell temperature (Celsius/Fahrenheit).

Figure 4.2: Detailed Battery Data Display
4.2. Customizable Settings
The device offers over 12 customizable parameters through its settings menu.

Figure 4.3: Customizable Settings Menu (Firmware V3.01)
Example Settings:
- Brightness Nrm: Adjust screen brightness (e.g., 70%).
- Brightness Idle: Set brightness when idle (e.g., 20%).
- Auto Off Timer: Configure automatic screen off time (e.g., 30s).
- CHG A-Off Tmr: Charger auto-off timer (e.g., 16s).
- CHG Chrg Pwr: Set charging power (e.g., 8W).
- ACC Term SOC: Accumulation mode termination SOC (e.g., 95%).
- PBK Qut Volt: Power bank output voltage (e.g., 5.00V).
- PBK Term SOC: Power bank termination SOC (e.g., 10%).
- EVO Chrg Pwr: Even Out mode charging power (e.g., 8W).
- EVO SOC Rnge: Even Out mode SOC range (e.g., 20-80).
5. Maintenance
5.1. Temperature Protection
The SYMIK charging case features rigorous high and low temperature charging protection, monitoring battery temperature 600 times per hour.

Figure 5.1: Temperature Zoning and Charging Strategy
Temperature Zoning and Charging Strategy:
| Temperature Range | Charging Current | Safety Logic |
|---|---|---|
| Cold (0 - -10°C) | Do not charge | Low-temperature electrolyte solidification can easily cause short circuits. |
| Cool (0-10°C) | Reduce current (e.g., 30%) | Reduce battery wear and prevent lithium plating. |
| Normal (10-45°C) | Maximum current | Optimal charging range for highest efficiency. |
| Warm (45-60°C) | Reduce current (e.g., 80%-20%) | High-temperature lithium ions are active and prone to bulging. |
| Hot (>60°C) | Do not charge | High-temperature electrolyte decomposition poses a high risk of explosion. |
5.2. Cleaning and Care
- When foreign objects appear on the lens protector, it is recommended to use a lens pen, lens blower, lens cloth, or similar tools for cleaning.
- When foreign objects appear on the lens, it is recommended to use a lens pen, lens blower, lens cloth, or similar tools for cleaning.
- When foreign objects appear in the battery or battery compartment, please use a dry, soft cloth or paper for cleaning.
5.3. Battery Precautions
- Only use official batteries. Using non-official batteries may lead to battery accidents or device malfunctions, for which Insta360 will not be responsible.
- Use batteries within the temperature range of -20°C to 40°C. High temperatures can cause battery swelling, fire, or even explosion. At low temperatures, it is recommended to fully charge the battery at room temperature before use to extend battery life. After use, allow the battery to cool to room temperature before charging. Charging outside the 0°C to 40°C range may damage the battery.
- Long-term storage of depleted batteries can affect their performance.
- Recharge and discharge the battery approximately every 3 months to maintain battery activity.
6. Specifications

Figure 6.1: Product Specifications
| Feature | Detail |
|---|---|
| Operating Temperature | 32° to 104°F (0° to 40°C) |
| USB-C Input | 5V 3A; 9V 3A; (27W Max) |
| Charge Power (Per Channel) | Up to 20W adjustable |
| Power Bank Mode USB-C Output | 5V 2.1A (10.5W) |
| Charging Time at Room Temp* | 0% to 80% in 35min @ 12W 0% to 100% in 50min @ 12W |
| Product Size | 2.99*2.36*1.89 inch (76*60*48 mm) |
| Product Weight | 4.1 Ounces / 115 grams |
| Product Color | High Tech Gray |
7. Troubleshooting
7.1. Charging Issues
If your charger is not fast charging, ensure you are using a 9V/2A (27W Max) power adapter and official Insta360 X4 Air batteries. Check the USB-C cable for damage and ensure it is properly connected.
7.2. Screen Not Displaying Parameters
If the screen is not displaying parameters, try the following:
- Open the lid, press the button, or insert a battery to wake up the screen.
- Ensure batteries are correctly inserted and have some charge.
8. User Tips
- The SYMIK Intelligent Charging Case provides a convenient way to charge your Insta360 X4 Air batteries without needing to open the camera's charging port, reducing wear and tear on the camera.
- Utilize the 'Accumulation Mode' to combine partially charged batteries for extended shooting sessions, avoiding interruptions.
- The 'Even Out Mode' is excellent for long-term battery storage, helping to maintain battery health by balancing the charge levels.
9. Warranty and Support
For warranty claims, technical support, or service inquiries, please contact SYMIK customer service or visit the official website.
Contact Information:
- Web: www.insta360.com (for Insta360 related support)
- Email: service@insta360.com