CNCEST LM149

Contents

Electric Gate Opener LM149 Electronic Lock

User Manual

Model: LM149 | Brand: CNCEST

Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Electric Gate Opener LM149 Electronic Lock. Designed for enhanced security and convenience, this lock features robust Q235 steel construction, IP44 protection, and dual unlocking methods. Please read this manual thoroughly before use to ensure proper functionality and longevity of the product.

Specifications

Feature Detail
Model LM149
Material Q235 Steel
Process Electrostatic Spraying
Color Black
Assembly Required No
Power Supply Wired
Control Mode Access Control System / Key
Locking Method Collision / Power-Off
Unlock Time 1 second
Working Voltage 24V
Power 60W
Working Current 2.5A
Protection Level IP44
Working Temperature -20~60℃ / -4~140℉
Power Cord Length 5m / 16.4ft
Installation Holes Spacing 50mm / 2in
Lock Size (L*W*H) 32*7.5*11.5CM (105*219.2*50mm / 4.1*8.6*2in)
Throw Length 32CM
Net Weight 1.7kg / 3.75lbs

Package Contents

  • 1 * Electric Gate Lock
  • 1 * Lock Receiver
  • 2 * Keys
  • 1 * English Manual

Setup and Installation

The LM149 Electric Gate Lock is designed for straightforward installation. While assembly is not required, proper mounting and wiring are crucial for optimal performance and security.

  1. Compatibility Check: Ensure your existing gate opener system has a DC 24V output signal for electric lock terminals. This product is compatible with most third-party door openers for double doors and single swing doors, including models like BI-WWHYYR-2729 and HG-WWHYYR-4770. Note: This product is not compatible with DC12V door-opening systems.
  2. Mounting Location: Choose a suitable location on your gate and gate post for the lock and receiver. The installation holes spacing is 50mm (2in). Consider the 16.4-foot power cord length for flexible placement.
  3. Secure Mounting: Mount the electric gate lock and its receiver securely using appropriate hardware (not included, typically provided with the gate opener system or purchased separately). Ensure the lock and receiver align perfectly for smooth operation.
  4. Wiring: Connect the lock to your gate opener's control board according to the instructions provided with your gate opener system, ensuring the 24V DC output is used. The power cord is 16.4 feet long to provide ample operation space.
  5. Initial Test: After installation, perform a test run to ensure the lock engages and disengages correctly with your access control system and the provided spare keys.
Electric gate lock installed on a gate, highlighting high security, easy to lock, simple installation, and easy to clean.

Figure 1: Electric gate lock installed, emphasizing key features like security and ease of installation.

Image showing the lock and receiver components, with examples of different gate types it can be used with (sliding, swing, car).

Figure 2: Components of the lock and receiver, illustrating compatibility with various gate types.

Operating Instructions

The LM149 Electronic Lock offers reliable and flexible operation for your gate security.

Locking Mechanism:

  • Automatic Locking: The lock is designed to engage with minimal force upon gate closure, ensuring it locks effectively without requiring manual intervention. This collision/power-off locking method helps prevent accidental unlocking.

Unlocking Methods:

  • Access Control System: Integrate the lock with your existing gate opener's access control system. The lock will disengage in approximately 1 second when a valid signal is received from your remote control or other access device.
  • Spare Keys: In case of power outages or access control system failure, use one of the two provided spare keys to manually unlock the gate. This ensures continuous access even under unforeseen circumstances.
Electric gate lock illustrating two unlocking methods: Access Control System and Spare Keys.

Figure 3: The two primary unlocking methods for the LM149 lock.

Woman using a key to unlock a gate, demonstrating one of the unlocking methods.

Figure 4: Manual unlocking using a spare key.

Maintenance

Regular maintenance ensures the longevity and optimal performance of your LM149 Electronic Lock.

  • Cleaning: The lock's smooth, electrostatic-sprayed Q235 steel surface is easy to clean. Simply use a soft cloth to wipe away dust and debris. Avoid abrasive cleaners or solvents that could damage the finish.
  • Inspection: Periodically inspect the lock and receiver for any signs of wear, damage, or misalignment. Ensure all mounting hardware is secure.
  • Lubrication: If the locking mechanism feels stiff, apply a small amount of silicone-based lubricant to the moving parts of the lock tongue and keyhole. Avoid oil-based lubricants that can attract dirt.
  • Environmental Protection: The IP44 protection level and robust Q235 steel with electrostatic spraying provide excellent resistance to corrosion and harsh weather conditions, including temperatures from -4°F to 140°F. No special winterization or summerization is typically required beyond routine cleaning.
Electric gate lock overview, highlighting Q235 Steel, High Hardness, IP44 Protection Level, and Corrosion Prevention.

Figure 5: The durable Q235 steel construction with IP44 protection ensures long-lasting performance.

Image showing 'More Details' with 'Smooth Edges' and '16.4FT Power Cord'.

Figure 6: Smooth edges reduce risk during handling and cleaning.

Troubleshooting

If you encounter issues with your LM149 Electronic Lock, refer to the following common problems and solutions:

  • Lock Not Engaging/Disengaging:
    • Check power supply: Ensure the lock is receiving a stable 24V DC power supply from your gate opener system.
    • Verify wiring: Inspect all electrical connections for looseness or damage.
    • Check alignment: Ensure the lock and receiver are perfectly aligned. Misalignment can prevent proper engagement.
    • Test with key: If using the access control system, try unlocking with a spare key to rule out system issues.
  • Lock Stiff or Slow to Respond:
    • Clean and lubricate: Clean any debris from the locking mechanism and apply a silicone-based lubricant as described in the Maintenance section.
    • Check for obstructions: Ensure no physical obstructions are impeding the lock's movement.
  • Power Outage:
    • Use spare keys: The lock is designed with two unlocking methods, including manual key access, specifically to address power outages or access system failures.
  • Incompatibility with Gate Opener:
    • Ensure your gate opener provides a 24V DC output signal for electric locks. This product is not compatible with 12V DC systems.

User Tips

  • Always keep your spare keys in a safe, accessible location, but not directly on the gate or near the lock, to ensure access during power outages or system malfunctions.
  • Regularly check the alignment of the lock and receiver. Even slight shifts over time can affect performance.
  • For optimal security, ensure the lock is integrated with a reliable 24V DC gate opener system.

Warranty and Support

For any questions, technical support, or warranty inquiries regarding your LM149 Electric Gate Opener Electronic Lock, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific contact details.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.