1. Introduction
This manual provides essential information for the safe and effective use of your SALORIE CPAP Heating Tube. This heated breathing circuit is designed to be used with ventilators that do not have a built-in heating function, providing warmth to the air delivered to the user. Please read this manual thoroughly before use and retain it for future reference.
2. Safety Information
Please observe the following safety precautions to prevent injury or damage to the device:
- The standard tensile force for heating the breathing circuit is within the range of 45 Newtons (N). Exceeding this value can easily damage the tube body.
- Do not apply additional heat to any part of the heated breathing circuit. This includes covering it with a quilt, using it in a neonatal incubator, or heating it under the heating head of a resuscitation table.
- When discontinuing the use of the ventilator, always turn off the power supply to the heating circuit first.
- Always consult with a healthcare professional before using any medical device, including this heating tube, to ensure it is appropriate for your specific medical condition.
3. Package Contents
Verify that all items are present in your package:
- 1 x SALORIE CPAP Heating Tube
- 1 x Power Adapter (Plug type may vary by region: EU, US, UK, AU)

Image: SALORIE CPAP Heating Tube and Power Adapter.
4. Setup Instructions
Follow these steps to properly set up your CPAP Heating Tube:
- Unpack the CPAP Heating Tube and power adapter from their packaging.
- Ensure your ventilator is turned off and unplugged from its power source before making any connections.
- Connect one end of the CPAP Heating Tube to the air outlet of your ventilator. Ensure a secure and airtight fit.
- Connect the other end of the CPAP Heating Tube to your CPAP mask or humidifier.
- Locate the power connector on the CPAP Heating Tube (usually near one end).
- Connect the small plug from the power adapter into the heating tube's power port.
- Plug the power adapter into a suitable electrical wall outlet.
- Verify all connections are secure and properly seated before powering on the ventilator.
Video: Demonstration of the CPAP Heating Tube's flexibility and power cable connection.

Image: Close-up of the tube's electrical connector pins.

Image: Close-up of the tube ends, illustrating the internal structure and connection points.

Image: The CPAP Heating Pipe, designed for ventilators without a built-in heating function.

Image: Power adapter with specifications (Model JRY024A1202000US, Input: 100-240V~50/60Hz 0.6A, Output: 12.0V === 2.0A).
5. Operating Instructions
Once the CPAP Heating Tube is properly connected and the power adapter is plugged in, you can begin using your ventilator. The heating tube will automatically warm the air passing through it to a comfortable temperature. This device operates at a fixed temperature and does not offer user-adjustable temperature settings.
6. Maintenance
Regular cleaning and inspection of your CPAP Heating Tube are crucial for hygiene and to ensure optimal performance and longevity of the product.
Cleaning:
- Disconnect the heating tube from the ventilator and unplug the power adapter from the wall outlet.
- Gently wash the interior and exterior of the tube with mild soap and warm, clean water. Avoid harsh chemicals or abrasive cleaners.
- Rinse the tube thoroughly with clean water to remove all soap residue.
- Allow the tube to air dry completely before re-connecting it to the ventilator or power supply. Do not use heat sources (like a hairdryer) to speed up drying.
Inspection:
- Regularly inspect the tube for any signs of wear, cracks, punctures, or damage.
- Check the power adapter and its cable for any fraying or damage.
- If any damage is found, discontinue use immediately and replace the affected component.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Tube is not heating | Power adapter not connected or faulty; Wall outlet not functional. | Check that the power adapter is securely connected to both the heating tube and a functional wall outlet. Inspect the adapter for damage. |
| Air leakage from connections | Tube ends not securely attached. | Ensure both ends of the heating tube are firmly and correctly attached to the ventilator/humidifier and mask. |
| Power adapter plug does not fit wall outlet | Regional plug incompatibility. | Use a suitable regional plug adapter. Ensure the adapter makes proper and secure electrical contact. |
| Tube does not fit ventilator port | Incompatibility with specific ventilator model (e.g., Philips Max). | Verify your ventilator's port size. This tube has a standard 22mm interface. Not all ventilators may be compatible. |
8. Specifications
| Feature | Detail |
|---|---|
| Brand Name | SALORIE |
| Model Number | CPAP Heating Tube |
| Item Type | Sleep & Snoring |
| Work Mode | CPAP |
| Material | Plastic |
| Pressure Range | 4-20 cmH2O (Note: This is typically a setting on the CPAP machine, not the tube itself.) |
| Application | Extraoral use |
| Electronic | No (refers to the tube itself, the heating element is electronic) |
| Batteries Included | No |
| Number of Pieces | One Unit |
| Pipe Interface Diameter | 2.2 cm (22 mm) |
| Package Length | 20 cm |
| Package Width | 10 cm |
| Package Height | 8 cm |
| Package Weight | 0.45 kg |
9. User Tips
- Some users have noted that the power adapter plug might be specific to certain regions (e.g., UK plug) and may require an adapter for other regions. Always ensure any adapter used makes good electrical contact.
- This heating tube provides a fixed temperature. If you require adjustable temperature, ensure your ventilator or humidifier has that functionality, or consider a different heated tubing solution.
- Always double-check the interface diameter (22mm) to ensure compatibility with your specific CPAP machine or mask before purchase and use.
10. Frequently Asked Questions (FAQ)
- Q: Does this tube have temperature adjustment?
- A: No, this CPAP heating tube operates at a fixed temperature and does not have user-adjustable temperature settings.
- Q: What is the diameter of the tube interface?
- A: The pipe interface diameter is 2.2 cm (22 mm).
- Q: Is this compatible with all CPAP machines?
- A: It is designed for ventilators without a heating function and has a standard 22mm interface. However, specific models (e.g., Philips Max) may have different interface requirements, so always verify compatibility with your device.
- Q: What should I do if the power plug doesn't fit my outlet?
- A: You may need a regional adapter. Ensure any adapter used provides a secure and proper electrical connection.
11. Warranty and Support
For warranty information or technical support, please refer to the seller's official store or contact their customer service directly. Keep your purchase receipt as proof of purchase.
You can also refer to the User manual (PDF) for additional details.