LEIRONG LP1500-DC

Contents

LEIRONG LP1500 DC Motor Peristaltic Pump User Manual

Model: LP1500-DC

Manufacturer: Lei Rong Fluid Tech (Shanghai) Co.,Ltd.

1. Introduction

The LEIRONG LP1500 DC Motor Peristaltic Pump is a compact and efficient fluid transfer solution designed for various applications requiring precise and stable liquid handling. This manual provides essential information for the safe and effective installation, operation, and maintenance of your LP1500 pump.

Key features include a transparent housing for visual monitoring, a low-noise brushed DC motor, multi-gear transmission for precise control, and a compact structure with a card slot design for easy tube replacement.

Front view of the LEIRONG LP1500 DC Motor Peristaltic Pump
Figure 1: Front view of the LP1500 Peristaltic Pump.

2. Safety Information

Please read and understand all safety instructions before operating the pump. Failure to follow these instructions may result in injury or damage to the product.

  • Ensure the power source matches the pump's voltage requirements (12V or 24V DC).
  • Do not operate the pump with damaged tubing or electrical components.
  • Avoid exposing the pump to extreme temperatures or corrosive environments unless specifically designed for such conditions.
  • Disconnect power before performing any maintenance or tube replacement.
  • Keep hands and loose clothing away from moving parts during operation.
  • This pump is designed for low-pressure applications. Do not exceed specified pressure limits.

3. Product Overview and Components

The LP1500 peristaltic pump features a robust design with several key components ensuring reliable performance.

Structural decomposition of the LP1500 pump showing internal components
Figure 2: Structural decomposition of the LP1500 Peristaltic Pump.

Key Features:

  • Transparent Housing: Allows for visible operation and a sleek appearance.
  • Brushed DC Motor: Provides low noise and stable performance.
  • Multi-Gear Transmission: Ensures precise control and balanced load.
  • Compact Structure: Features a slot design for easy tube replacement and secure positioning.
  • Dual-Bearing Support: Contributes to smooth operation and reduced vibration/noise.
  • Machined Rollers: Designed with a small gap to prevent damage to the pump tube during operation.
  • Precision Gears: Operate smoothly for consistent performance.
Detail of the card slot structure for stable pump tube
Figure 3: Card Slot Structure for stable pump tube installation.
Diagram showing machined rollers inside the pump
Figure 4: Machined Rollers ensuring smooth operation and tube longevity.
Internal view of the DC motor with service life and voltage details
Figure 5: DC Motor with 1000H service life and 12V/24V voltage options.
Diagram illustrating precision gears for smooth operation
Figure 6: Precision Gears for smooth and stable operation.

4. Model Definition

The LP1500 model number provides information about its configuration:

Diagram explaining the LP1500 model number breakdown
Figure 7: LP1500 Model Definition.
  • LP1500: Base model designation.
  • D24 / D12: Indicates the DC Motor voltage (D24 for 24V, D12 for 12V).
  • S64 / S79 / N64 / N79: Specifies the pump tube type and size.
    • S: Silicone Tube
    • N: Norprene Tube
    • 64: ID 6.4mm × OD 9.6mm
    • 79: ID 7.9mm × OD 11.1mm
  • A: Denotes the installation mode (Type A).

5. Installation

The LP1500 pump is designed for easy integration. Refer to the following diagrams for installation dimensions and method.

Detailed installation method diagram for Type A
Figure 8: Installation Method (Type A) with dimensions and opening size.

Installation Steps (Type A):

  1. Prepare an opening with the specified dimensions (refer to Figure 8, "Opening size A"). The opening diameter is Ø50mm with three M3 screw holes.
  2. Mount the pump unit into the prepared opening, ensuring the motor is positioned correctly.
  3. Secure the pump using appropriate screws through the mounting holes.
  4. Connect the inlet and outlet tubing to the pump's ports.
  5. Connect the DC motor to the appropriate power supply (12V or 24V DC) according to the pump's voltage specification.

6. Operation

The LP1500 peristaltic pump operates by compressing and releasing the pump tube, creating a flow of liquid. The liquid only touches the inside of the pump tube, ensuring cleanliness and hygiene.

Diagram showing clean and hygienic liquid transfer where liquid only touches the pump tube
Figure 9: Clean and hygienic operation, liquid touches only the pump tube.

Starting the Pump:

  1. Ensure all connections (power, inlet, outlet tubing) are secure.
  2. Apply power to the DC motor.
  3. The pump will begin to operate, transferring liquid.

Flow Rate Control:

The LP1500 supports Fullspeed or PWM (Pulse Width Modulation) speed regulation for controlling the flow rate. Consult your system's control interface for adjusting the motor speed.

Video 1: Demonstration of the LP1500 Peristaltic Pump in operation.

7. Maintenance

Regular maintenance, especially pump tube replacement, is crucial for optimal performance and longevity of your LP1500 pump.

Pump Tube Replacement Procedure:

Step-by-step guide for changing the pump tube
Figure 10: Pump Tube Change Procedure.
  1. Unscrew: Unscrew the three screws on the pump casing to remove the cover.
  2. Remove Assembly: Carefully take out the pump pipe assembly from the pump head.
  3. Install New Tube: Fix one joint of the new pump tube into the card slot. Turn the synchronous disk to guide the pump pipe into position, then clamp the other joint securely.
  4. Reassemble: Install the pump cover and tighten the three screws to complete the tube change.

The service life of the pump tube varies depending on operating conditions, pipeline pressure, and liquid corrosiveness. Regular inspection of the tube for wear and tear is recommended.

8. Troubleshooting

If you encounter issues with your LP1500 pump, consider the following common troubleshooting steps:

  • No Flow or Reduced Flow:
    • Check power supply and connections.
    • Inspect pump tube for kinks, blockages, or excessive wear. Replace if necessary.
    • Ensure inlet and outlet tubing are not obstructed.
    • Verify correct tube installation in the card slot.
  • Unusual Noise or Vibration:
    • Check for loose screws on the pump casing.
    • Inspect pump tube for proper seating and ensure it's not rubbing against internal components.
    • Ensure the pump is securely mounted.
  • Leakage:
    • Inspect pump tube for cracks or punctures. Replace immediately if damaged.
    • Ensure all tube connections are tight and secure.

For persistent issues, contact customer support or refer to the full user manual PDF.

9. Specifications

Detailed technical specifications for the LEIRONG LP1500 DC Motor Peristaltic Pump:

Feature Specification
Model NumberLP1500-DC
StructurePeristaltic Pump, Reduction gear
Power SourceElectric
Motor TypeDC motor with feedback control
Voltage12V / 24V
Power (W)36W
PressureLow Pressure
Flow Rate Range≤1600 ml/min
Control ModeFullspeed / PWM speed regulation
Gear BoxIndependent research and development of long life
MaterialPA66+PC
Roller3-roller
Noise≤60dB
Lifetime≥1000H
Weight350g
Product Dimensions (L x W x H)123.4mm x 70.4mm x 84.2mm
Package Dimensions (L x W x H)23cm x 13cm x 15cm
CertificationCE, RoHS, ISO9001
OriginChina Mainland

Flow Rate by Tube Type (Reference Data):

Tube Material Tube Species ID×OD (mm) Flow Rate (12V/3A, ml/min) Flow Rate (24V/1.5A, ml/min) Tube Lifetime
Silicone S64 6.4×9.6 1180 1180 <200h
S79 7.9×11.1 1600 1600 <200h
Norprene N64 6.4×9.6 960 960 ≥1000h
N79 7.9×11.1 1400 1400 ≥1000h

Note: Flow rate data is for reference only, obtained from water tests at room temperature (20°C) and atmospheric pressure. Actual flow rates may vary depending on liquid properties, pressure, and pipeline length. The service life of the pump tube may vary depending on the operating conditions, pipeline pressure, and liquid corrosiveness.

10. User Tips

  • Tube Material Selection: Consider the chemical compatibility and required lifetime when choosing between Silicone and Norprene tubes. Norprene offers longer life and better chemical resistance for certain applications, while Silicone is generally lower cost.
  • Regular Cleaning: For applications involving food or sensitive liquids, ensure regular cleaning of the pump tube and connections to maintain hygiene.
  • Optimal Performance: To achieve the specified flow rates, ensure your power supply can deliver the required voltage and current (e.g., 12V/3A or 24V/1.5A).

11. Warranty and Support

LEIRONG provides 1 year of technical service for the LP1500 DC Motor Peristaltic Pump.

For further detailed information, technical assistance, or warranty claims, please refer to the official user manual PDF available at: LP1500 User Manual (PDF).

You may also contact Lei Rong Fluid Tech (Shanghai) Co.,Ltd. directly for support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.