1. Product Overview

The LEIRONG LP500 DC Motor Micro Peristaltic Pump is a compact and efficient pump designed for precise fluid delivery. It features a transparent housing for visible operation, a low-noise brushed DC motor, and a multi-gear transmission for stable and balanced load. The pump's design ensures that the liquid only comes into contact with the pump tube, maintaining hygiene and preventing contamination. It is suitable for various applications including aquarium circulation, beverage filling, water quality sampling, and ice cream makers.

Front view of the LP500 DC Motor Micro Peristaltic Pump
Figure 1: LP500 DC Motor Micro Peristaltic Pump (Front View)
Video 1: LP500 Peristaltic Pump in operation, demonstrating fluid transfer and internal mechanism.

2. Specifications

2.1 General Specifications

  • Brand Name: LEIRONG
  • Model Number: LP500-DC
  • Structure: Peristaltic Pump, Reduction gear
  • Theory: Rotary Pump
  • Power Source: Electric (DC Motor)
  • Pressure: Low Pressure
  • Application: Delivery
  • Standard or Nonstandard: Standard
  • Certification: CE, RoHS, ISO9001
  • Origin: China Mainland
  • High-concerned chemical: None
  • Batteries: Not included
  • Motor Service Life: ≥1000H
  • Reduction Ratio: 1:8
  • Patent: Utility model

2.2 Dimensions

Product size diagram showing height, width, and length of the LP500 pump.
Figure 2: Product Dimensions
LP500 Pump Dimensions (Approximate)
Measurement Value
Length (including motor) 120.8 mm
Pump Head Height 43.7 mm
Total Height (with connections) 72.7 mm
Width 53.9 mm
Motor Diameter Ø 39.6 mm

2.3 Flow Rate Parameters

The LP500 pump offers various tube material and species options, each with different flow rates and characteristics. The data below is for reference only, obtained from LEIRONG's laboratory under specific conditions (water test at 20°C, atmospheric pressure, ambient temperature 0–50℃, relative humidity <80%). Actual flow rates may vary depending on liquid properties, pipeline pressure, and length.

LP500 Peristaltic Pump Flow Rates (ml/min)
Tube Materials Tube Species ID×OD 12V/3A Flow (ml/min) 24V/1.5A Flow (ml/min)
Silicone tube S40 4×7.2 450 450
S48 4.8×8 600 600
Norprene tube N40 4×7.2 400 400
N48 4.8×8 500 500

Tube Life: Norprene tubes offer a life of ≥1000h, while Silicone tubes have a life of <200h under continuous operation at 430r/min and 20°C with water. Slower rotational speeds generally extend tube life.

3. Setup and Installation

3.1 Model Interpretation

The LP500 model designation follows a specific format: LP500 - DXX TXX A

  • 1. Motor (DXX):
    • D12: 12V DC Motor
    • D24: 24V DC Motor
  • 2. Tube (TXX):
    • S: Silicone Tube (e.g., S40, S48)
    • N: Norprene Tube (e.g., N40, N48)
  • 3. Installation Mode (A):
    • A: Standard Installation Mode (as shown in diagrams)
Diagram explaining the LP500 model definition: motor type, tube type, and installation mode.
Figure 3: LP500 Model Definition Breakdown

3.2 Mounting the Pump

The LP500 pump is designed for easy integration. Refer to the installation diagrams for precise mounting dimensions and procedures.

Side view of the LP500 pump, showing the motor and mounting points.
Figure 4: LP500 Pump Side View with Mounting Points
Another side view of the LP500 pump, highlighting the motor and overall structure.
Figure 5: LP500 Pump Side View
Diagram showing the LP500 pump installed through a panel, with liquid being conveyed.
Figure 6: Type A Installation Diagram

For detailed mounting hole dimensions, please refer to the 'Opening size(A)' diagram in the PDF manual (page 4).

4. Operating Instructions

The LP500 peristaltic pump operates by compressing and relaxing a flexible tube, pushing fluid through. This design ensures that the fluid never touches the pump mechanism, only the inside of the tube, making it ideal for hygienic applications.

4.1 Key Features in Operation

  • Bidirectional Conveying: The pump can move fluid in both directions, offering flexibility in application.
  • Clean and Hygienic: As liquid only contacts the pump tube, cross-contamination is minimized, making it suitable for sensitive fluids.
  • Low Noise Operation: The brushed DC motor and precision gears are designed for quiet performance.
  • Stable Output: Dual-bearing support and multi-gear transmission ensure smooth operation and stable fluid output.
Internal view of the pump showing rollers compressing the tube for bidirectional conveying.
Figure 7: Bidirectional Conveying Mechanism
Close-up of the pump's precision gears, indicating smooth operation.
Figure 8: Precision Gears for Smooth Operation

5. Maintenance

5.1 Pump Tube Replacement Procedure

The pump tube is a consumable part and will need periodic replacement depending on usage and fluid type. The LP500 features a compact structure with a slot design for easy tube replacement.

  1. Loosen Screws and Remove Cover: Loosen the fixing screws on the pump cover and carefully remove the transparent pump cover.
  2. Take Out Pump Pipe Assembly: Gently remove the old pump pipe assembly from its position.
  3. Install New Tube: Fix one joint of the new tube in the card slot, turn the synchronous disk to guide the tube, and then clamp the other joint securely. The guide wheel design helps prevent pipe displacement.
  4. Reinstall Cover: Install the pump cover back and tighten the screws to complete the tube change.
Four-step diagram illustrating the procedure for changing the pump tube: loosening screws, removing assembly, installing new tube, and reinstalling cover.
Figure 9: Tube Change Procedure

Ensure the correct tube material and size are used for replacement, matching your application's requirements (refer to Section 2.3 for tube specifications).

6. Troubleshooting

This section provides general guidance for common issues. For persistent problems, please contact customer support.

  • No Flow or Reduced Flow:
    • Check power supply and connections.
    • Inspect the pump tube for kinks, blockages, or wear. Replace if necessary.
    • Ensure the fluid source is not empty and there are no air bubbles in the line.
    • Verify the motor is running.
  • Unusual Noise:
    • Check for foreign objects near the pump head or motor.
    • Ensure the pump is securely mounted and not vibrating against a surface.
    • Inspect the pump tube for proper installation and wear.
  • Leakage:
    • Verify all tube connections are tight and secure.
    • Inspect the pump tube for cracks or punctures. Replace if damaged.
    • Ensure the pump cover is properly installed and screws are tightened.

7. User Tips

  • Tube Selection: Always choose the appropriate pump tube material (Silicone or Norprene) based on the chemical compatibility and required service life for your specific application. Norprene offers longer life and better chemical resistance for certain fluids.
  • Regular Inspection: Periodically inspect the pump tube for signs of wear, discoloration, or hardening, especially if used with corrosive liquids or at high speeds.
  • Optimal Performance: For consistent flow rates, ensure the pump is operated within the suggested working conditions (ambient temperature 0–50℃, relative humidity <80%).
  • Customization: Remember that the pump tube material, flow rate, and control method can be customized to meet specific needs. Contact LEIRONG for custom solutions.

8. Warranty and Support

LEIRONG Fluid Tech (Shanghai) Co.,Ltd. provides technical support for its products. For any inquiries, technical assistance, or warranty claims, please use the contact information below.

  • Contact Person: Alex
  • Telephone/WeChat: 15316363092
  • E-mail: 15316363092@163.com
  • Company: Lei Rong Fluid Tech (Shanghai) Co.,Ltd.
  • Website: www.lrfluid.com

The company is committed to continuous development of products and providing fluid solutions, with a focus on quality and customer satisfaction.

© 2023 Lei Rong Fluid Tech (Shanghai) Co.,Ltd. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.