1. Product Overview
The Dooya DM35EQL-8/17 is an electronic tubular motor designed for various rolling blinds. It features an integrated RF433 module and supports RS485 protocol for advanced control. This motor operates on 220V/230V at 50/60Hz and includes a 3-wire connection system.


2. Safety Information
- It is strictly prohibited to beat the motor during transport, storage, installation, and use.
- Minimize motor vibration during operation.
- Ensure the power is off before performing any installation or maintenance.
- This product complies with EU RoHS directives. Do not dispose of it as household waste. Please recycle it in accordance with local regulations for waste electrical and electronic equipment.
3. Installation
3.1. Crown and Drive Adapter Selection
The motor comes with a crown and drive adapter. The specific type provided depends on the rolling tube you intend to use. It is crucial to ensure compatibility with your tube's inner structure.
- Different rolling tubes, even with the same outer diameter, may have varying inner structures.
- You may need to modify the provided crown and drive adapter to fit your tube.
- Alternatively, you can use 3D printed adapters or source compatible parts locally.
- If your existing crown and drive adapter are in good condition and compatible, it is recommended to reuse them.

Crown and Drive Adapter Examples:
For 40mm Round Tube:

Crown and drive adapter for 40mm round tube. For 40mm Octagonal Tube:

Crown and drive adapter for 40mm octagonal tube. For 45mm Groove Tube:

Crown and drive adapter for 45mm groove tube. For 47mm Groove Tube:

Crown and drive adapter for 47mm groove tube. For 50mm Groove Tube:

Crown and drive adapter for 50mm groove tube. For 50mm Round Tube (Drive Adapter Only, No Crown Needed):

Drive adapter for 50mm round tube (no crown required).
3.2. Drive Adapter Installation
Follow these steps to install the drive adapter into the tubular motor and then into the rolling tube.

Warning: Forbidden to drill through the crown and inner gear wheel.
3.3. Bracket Installation
Mount the motor using appropriate brackets. Ensure secure fastening to prevent vibration and ensure proper operation.

3.4. Circuit Installation (Wiring)
Connect the motor to the power supply and RS485 interface according to the diagram below. Ensure the power is off before wiring.

- Blue wire: Neutral
- Brown wire: Live
- Green/Yellow wire: Earth
- Connect to an External RS485 Interface as needed.
4. Operation
4.1. Initial Setup and Pairing
This motor is an RS485 Electronic tubular motor with a built-in RF433 module. It can be controlled by RS485 or Dooya RF433 remote controllers (e.g., DC2700) or RF433 wall switches (e.g., DC1651).
Important: During settings, the time between two operations must be shorter than 6 seconds, otherwise it will exit the setting mode. If the motor has already been matched with a code, its memory will be cleared if you repeat the process.

- Switch off power for >10 seconds, then switch on. The motor will run for a hint.
- Press the setting button on the motor once. The motor will beep 3 times and run for a hint.
- Press the P2 button on the remote control once (motor beeps once).
- Press the P2 button on the remote control once again (motor beeps once).
- Press the P2 button on the remote control three times (motor beeps 3 times and runs for a hint).
- The setup is complete. The Up limit button controls the motor clockwise. The Down limit button controls the motor counter-clockwise.
4.2. Setting Up/Down Limit Positions
Note: It is invalid when the up limit and down limit are at the same location. After limit setting, with power and memory function, the motor will quit the setting limits status automatically into the match-code status 2 minutes later. The step-moving status allows for more precise adjustment.

- Set Up Limit Position:
- Press P2 button once (motor beeps once, runs for hint).
- Press Up button once (motor beeps 3 times, runs for hint).
- Adjust the blind to the desired up limit position using the remote.
- Press Stop button once (motor stops).
- The up limit is set.
- Set Down Limit Position:
- Press Down button once (motor runs for hint).
- Adjust the blind to the desired down limit position using the remote.
- Press Stop button five times (motor stops).
- The down limit is set.
4.3. Setting a Third Limit Position
After setting the up and down limits, you can set a third intermediate limit position.

- To Set the Third Limit Position:
- Ensure up and down limits are already set.
- Press Stop button once (motor stops).
- Press P2 button once (motor beeps once).
- Press Stop button once (motor beeps once).
- Press P2 button three times (motor beeps 3 times, runs for hint).
- The third limit position is set.
- To Cancel the Third Limit Position:
- Power on the motor. The roller blind will move to the third limit.
- Press P2 button once (motor beeps once).
- Press P2 button once again (motor beeps once).
- Press P2 button three times (motor beeps 3 times, runs for hint).
- The third limit position is cancelled.
4.4. Adding/Deleting Emitters (Remote Controls)

- To Add an Emitter:
- Using an already matched remote (Emitter 'a'): Press P2 button once (motor beeps once).
- Press P2 button on Emitter 'a' once again (motor beeps once).
- Using the new remote (Emitter 'b'): Press P2 button three times (motor beeps 3 times, runs for hint).
- Emitter 'b' is now added.
- To Delete All Emitters:
- Press P2 button once (motor beeps once).
- Press Stop button once (motor beeps once).
- Press P2 button three times (motor beeps 3 times, runs for hint).
- All emitters are deleted from the motor's memory.
4.5. Setting Up with RS485
For control via RS485 protocol, follow these steps to enable communication.

- Press the setting button on the motor for 1 second. The motor will beep 3 times and run for a hint.
- Send open or close commands from your RS485 equipment.
- The RS485 equipment light should go out, indicating successful setup.
4.6. Light Adjust Function
This function allows adjustment of illumination if supported by your blind system.

- To Activate Light Adjust Function:
- Press P2 button once (motor beeps once).
- Press Up button once (motor beeps once).
- Press Down button three times (motor beeps 3 times, runs for hint).
- The light adjust function is now active. Short presses on Up/Down buttons adjust illumination with a 'dit' move; long presses (over 2 seconds) adjust continually.
- To Close Light Adjust Function:
- Press P2 button once (motor beeps once).
- Press Up button once (motor beeps once).
- Press Down button three times (motor beeps 3 times, runs for hint).
- The light adjust function is now closed.
5. Specifications
| Feature | Specification |
|---|---|
| Model Number | DM35EQL/J016-8/17 (also DM35EQL-8/17) |
| Rated Torque | 8 N.m |
| Rated Power | 98 W |
| Running Speed | 17 r/min |
| Rated Current | 0.43 A |
| Power Supply Voltage | 220V/230V |
| Frequency | 50/60 Hz |
| Operation Time | S2 4min |
| Protection Grade | IP44 |
| Insulation Class | H |
| Motor Diameter | Φ35 mm |
| Communication Method | RS485 Protocol, RF433 Wireless |
| Control Range (Air) | 200 m |
| Control Range (Concrete Walls) | 35 m |
| Emission Frequency | 433.92 MHz |
| Max Channels | 20 (additional emitters needed for more) |
| Length | 498 mm |
| Weight | 1.54 kg (motor only) / 1.9 kg (package) |


6. Maintenance
To ensure the longevity and optimal performance of your Dooya tubular motor, consider the following general maintenance guidelines:
- Keep the motor and surrounding area clean and free from dust and debris.
- Avoid exposing the motor to excessive moisture or extreme temperatures.
- Regularly check the wiring for any signs of wear or damage.
- Ensure that the roller blind mechanism operates smoothly without obstruction, which could put undue strain on the motor.
- Do not attempt to lubricate internal components unless specifically instructed by the manufacturer.
7. Troubleshooting
If you encounter issues with your motor, consider these basic troubleshooting steps:
- Motor not responding: Check power supply. Ensure the remote control batteries are not depleted. Re-pair the remote control if necessary (refer to Section 4.1).
- Blind not moving to correct limits: Re-set the upper and lower limit positions (refer to Section 4.2). Ensure no physical obstructions are preventing the blind from reaching its limits.
- Motor making unusual noises: Check for any obstructions in the roller blind mechanism. Ensure the motor is securely mounted and not vibrating excessively.
- Remote control issues: Verify the remote is within the effective control range (200m in air, 35m with concrete walls). Ensure no strong interference sources are nearby.
If problems persist, contact customer support or a qualified technician.
8. User Tips
- For optimal performance and control, consider using official Dooya RF433 remote controllers or wall switches.
- When dealing with different tube types, carefully verify the inner structure to ensure the correct crown and drive adapter are used or modified.
- If you are comfortable with 3D printing, custom-made crown and drive adapters can be a viable solution for unique tube configurations.
9. Warranty and Support
This product has undergone EU conformity assessment and complies with the following directives:
- Low Voltage Directive 2014/35/EU (LVD)
- Electromagnetic Compatibility Directive 2014/30/EU (EMC)
- Restriction of Hazardous Substances Directive 2011/65/EU (RoHS)
- General Product Safety Regulation (GPSR)
The EU Declaration of Conformity (DoC) is issued, and technical documentation is kept by the EU Authorized Representative for inspection.
Manufacturer:
Name: Lumi United Technology Co., Ltd.
Address: 8th Floor, JinQi Wisdom Valley, No.1 Tangling Road, Liuxian Ave, Taoyuan Residential District, Nanshan District, Shenzhen, China
Tel: 86-18589043609
EU Authorized Representative:
Name: Sophie Bennett
Address: 9 rue du Bat d'Argent, 69001 Lyon, France
Tel: 33-774555006
Environmental Note:
This product complies with EU RoHS. Do not dispose of it as household waste. Please recycle it in accordance with local regulations for waste electrical and electronic equipment.