FUZRR ES6030 TTR

Contents

ES6030 TTR Turns Ratio Tester User Manual

Model: ES6030 TTR | Brand: FUZRR

1. Safety Rules and Precautions

Thank you for purchasing our transformer turns ratio tester. Before you use the instrument for the first time, in order to avoid possible electric shock or personal injury, please be sure to: read in detail and strictly observe the safety rules and precautions listed in this manual.

In any case, special attention should be paid to safety when using this instrument.

  • The instrument is designed, manufactured and tested in accordance with IEC61010 safety specifications.
  • In any case, special attention should be paid to safety when using this instrument.
  • Notice the labeled text and symbols on the body of this instrument.
  • Before use, it should be confirmed that the instrument and accessories are intact, and the insulation of the instrument and test line is not broken exposed,No broken wires to use.
  • During measurement, it is strictly prohibited to touch the exposed conductors and the circuit being measured.
  • Verify that the wire connection plugs are tightly inserted into the instrument connector.
  • Do not measure in flammable locations, sparks may cause an explosion.
  • Discontinue use of the instrument if metal is exposed due to breakage of the housing or test cable during use.
  • Do not place and store the instrument for a long time in a hot and humid place or under direct sunlight.
  • Pay attention to the measurement range specified for this instrument and the environment in which it is used.
  • The use, disassembly, calibration, and maintenance of this instrument must be carried out by authorized and qualified personnel.
  • If continued use poses a danger due to this instrument, stop using it and seal it immediately deposit, to be handled by an authorized and qualified body.
  • The "!" safety warning symbols in the instrument and in the manual must be strictly followed by the user in this manual.Allow for safe operation.

2. Introduction

ES6030 transformer turns ratio tester adopts microprocessor technology for measurement calculation and automatic control, which can quickly and easily measure the actual transformer ratio and group. It is mainly used in the power industry to measure the transformer ratio and group, and at the same time, it is used by transformer manufacturers and distributors to measure the transformer parameters.

ES6030 transformer ratio tester consists of host, monitoring software, test line, communication line and so on. The host has a charging function without the need to find power on site, full-colour large-screen LCD display, the language can choose Chinese or English, at a glance, touch-screen operation is convenient and easy to use, the port anti-overload function, large-capacity storage of 500 groups of data. Upper computer software with historical data reading, access, save and other functions.

ES6030 TTR Turns Ratio Tester connected to a three-phase transformer for testing.
ES6030 TTR Turns Ratio Tester connected to a three-phase transformer for testing.
Close-up view of the ES6030 TTR Turns Ratio Tester screen displaying test results and connections.
Close-up view of the ES6030 TTR Turns Ratio Tester screen displaying test results and connections.
Video demonstrating the user interface and operation of the ES6030 TTR Turns Ratio Tester, including setting parameters, running tests, and saving data.

3. Specifications

FeatureDescription
FunctionRatio and group testing of three-phase transformers, single-phase transformers, PT and CT. Blind testing of three-phase transformers, ratio and group testing of Z-type transformers.
Specimen TypeSingle phase transformer, three phase transformers, Z-type transformers, PT, CT
Ratio Range0.9~10000
Overload ProtectionYes
Power SourceDC9.6V 3800mAh high capacity lithium battery
Charging FunctionYes
Display Mode5-inch touchscreen (854x480 dots) full-color LCD display
Interactive ModeTouch screen / buttons
LCD Size (L x W)108 mm x 65 mm
Instrument Size (L x W x H)229 mm x 166 mm x 74 mm
Mobile APPYes, Bluetooth connection
Computer ConnectYes, USB cable connection
Data Storage500 groups
Data AccessData access function
Battery VoltageReal-time display, indicates need for timely charging when low.
Automatic Switch OffSettable for 1~30 minutes.
Power Dissipation (Standby)Approx. 2W (100% brightness)
Power Dissipation (Measurement)12W Max
Weight (Instrument)1.5kg (including battery)
Weight (Test Cables)1.7kg
Working Temperature & Humidity-10℃~40℃; below 70%rh
Storage Temperature & Humidity-20℃~60℃; below 70%rh
Insulation ResistanceAbove 10 MΩ (500V between circuit and housing)
Pressure ResistanceAC 3700V/rms (between circuit and enclosure)
Electromagnetic PropertyIEC61010-4-3, ratio frequency≤1V/m
Safety RegulationIEC61010-1, CAT III 600V, pollution class 2

3.1. Range and Accuracy

Measure the ratio rangeResolution ratioAccuracy
0.9 ≤ TTR < 100.0001±0.2% ±2dgt
10 ≤ TTR < 1000.001±0.2% ±2dgt
100 ≤ TTR < 10000.01±0.2% ±2dgt
1000 ≤ TTR < 20000.1±0.2% ±2dgt
2000 ≤ TTR < 100000.1±0.5% ±2dgt
10000 ≥ TTR1--
Calibration certificate for the ES6030 TTR Turns Ratio Tester.
Calibration certificate for the ES6030 TTR Turns Ratio Tester.

4. Instrument Structure

Diagram showing the structure of the ES6030 TTR Turns Ratio Tester with numbered parts.
Diagram showing the structure of the ES6030 TTR Turns Ratio Tester with numbered parts.

4.1. Keypad and Ports Overview

  1. HV side A phase
  2. HV side B phase
  3. HV side C phase
  4. AV side A phase
  5. AV side B phase
  6. AV side C phase
  7. USB PORT
  8. Power button
  9. Confirmation key
  10. Return key
  11. Test key
  12. Color screen
  13. Multi-function key
  14. Right button
  15. Left button
  16. Down button
  17. Upper button
  18. Charging port

5. Method of Operation

5.1. Switching On and Off

Pressing the red "power button" in the off state will turn the power on, and pressing the red "power button" in the on state will turn the power off.

5.2. Interface Overview

The main interface provides access to different test modes and settings.

Main interface of the ES6030 TTR Turns Ratio Tester showing options for Three phase, Single phase, Z-type tests, Set, View, and OPI.
Main interface of the ES6030 TTR Turns Ratio Tester showing options for Three phase, Single phase, Z-type tests, Set, View, and OPI.

5.3. Iconography and Controls

The device features both silicone keypad buttons and a touch screen for interaction. Below is a guide to the main icons and their functions.

IconNameNote
▲Upper keySelect upwards
▼Down keySelect downwards
◀Left keySelect to the left
▶Right keySelect to the right
Multiplex keyEquivalent to touching the bottom left button of the screen, including deleting, saving, sound, etc.
⏻Power buttonSwitching power supply
⏎Confirm keyConform or checked.
↩Return keyReturn to the previous screen
TESTTest keyStart testing

Touch Button Icons

IconNameNote
OKConfirm keyConform or checked.
↩Return keyReturn to the previous screen
▲Upper keySelect upwards
▼Down keySelect downwards
◀Left keySelect to the left
▶Right keySelect to the right
🗑️Delete keyDelete all the test records.
TimeTime keyEnter the set time interface
🔇Sound keySet the buzzer switch.
🔊Sound keySet the buzzer switch.
SaveSave keySave the test record
BLEBluetooth keySet up Bluetooth on or off.
EN/CNLanguage switchingSwitch between Chinese and English
TESTTest keyStart testing

Other Icons

IconNote
🔆Using for adjusting the brightness of the backlight.
🔋Battery level display
🔌Charging status display
블루투스 아이콘Bluetooth is displayed in the upper right corner of the large screen when it is switched on.
🔍View test record

5.4. Battery Level Check

1. After power on, if the upper right corner of the big screen shows the low battery voltage symbol, it means the battery power is insufficient, please charge it in time. The battery power is sufficient to ensure the accuracy of measurement.

2. The power consumption during the test is higher than standby, if the LCD shows low battery voltage symbol during the test, it means that the battery power is about to be insufficient, please fill up the power in time. In order to ensure the accuracy of the test.

3. The power is not enough to support the test will automatically shut down, please charge and then test.

5.5. Single-Phase Transformer Test

5.5.1. Wiring Methods

Wiring diagram for single-phase transformer test using ES6030 TTR Turns Ratio Tester.
Wiring diagram for single-phase transformer test using ES6030 TTR Turns Ratio Tester. Connect the two ports on the high-voltage side of the transformer to the tester's UA and UB terminals, and the two ports on the low-voltage side of the transformer to the tester's Ua and Ub terminals.

5.5.2. Test Operation

In the main interface, click on the "Single phase test" icon to enter the resistance test setup interface. You can adjust the specimen number, rated high voltage (HV), rated low voltage, tap spacing, and rated tap. After setting the parameters, click "TEST" or press the silicone button "TEST" to start the test. The test result will be displayed on the screen.

5.6. Three-Phase Transformer Test

5.6.1. Wiring Methods

Wiring diagram for three-phase transformer test using ES6030 TTR Turns Ratio Tester.
Wiring diagram for three-phase transformer test using ES6030 TTR Turns Ratio Tester. Connect the three ports (A, B, C) on the high-voltage side of the transformer to the tester's UA, UB, UC terminals, and the three ports (a, b, c) on the low-voltage side of the transformer to the tester's Ua, Ub, Uc terminals.

5.6.2. Test Operations

For conventional three-phase transformers with recognizable nameplates, click the "three phase test" icon and then "normal test". If the nameplate is not recognizable, choose "three-phase blind test". For Z-Type Transformers, click the "Z-Type Test" icon.

Similar to single-phase testing, you can adjust specimen number, rated HV, rated low voltage, tap spacing, and rated tap. The LINK GROUP contains three parameters: High-voltage side coupling methods (D, Y, YN, ZN, and unknown for blind testing) and Low-voltage side linkage (d, y, yn, and unknown). The "Auto" option is available for 3-phase blind tests.

After setting parameters, click "TEST" to begin. The test result will be displayed.

5.7. Settings

From the main interface, click the "Set" icon to access system settings. Here you can adjust:

  • Backlight: Drag the icon left or right to adjust brightness.
  • Shutdown Time: Set auto-shutdown from 1 to 30 minutes. The tester will power off automatically after this period of inactivity.
  • Sound: Toggle the buzzer sound on/off.
  • Language: Switch between Simplified Chinese and English.
  • Bluetooth: Toggle Bluetooth on/off. When on, the Bluetooth icon will appear in the upper right corner of the screen.
  • Time Setting: Enter the time setting interface to adjust year, month, day, hour, and second. Click "OK" to update.

5.8. Data Management

5.8.1. Data Storage

In the test result interface, click "Save" to store the test results. The tester can save up to 500 sets of test results. If storage is full, clear old records from the access screen before saving new data.

5.8.2. Data Access/Deletion

From the main interface, click the "View" icon to enter the access interface. If no data is saved, it will prompt "No saved data!". Use the left and right buttons to navigate pages, and the up and down buttons to select records. You can also directly click a record on the screen to view it. To delete records, use the "Delete" icon.

5.9. APP and PC Upper Computer Operation

The ES6030 supports connection to both Android APP and PC software.

5.9.1. PC Connection Instructions

Install the USB driver and host computer software from the provided CD-ROM. After switching on the instrument, connect it to the PC using the accessory USB cable. The software will automatically search for and connect to the port. Once connected, you can check historical data, generate Excel reports, and perform other operations.

5.9.2. Android APP Connection Instructions

Ensure your mobile phone or tablet runs Android 5.0 or above and has the TTR Tester APP installed. In the "Settings" page of the instrument, click the Bluetooth icon to turn on Bluetooth. Then, turn on the APP, search for the "TTR Tester" Bluetooth device, and connect. This enables wireless control measurement and data browsing.

6. Troubleshooting

  • Low Battery: If the low battery voltage symbol appears, charge the instrument immediately to ensure accurate measurements. The instrument may automatically shut down if the battery is too low during testing.
  • Overload Protection: If an overload is detected during pre-test checking, the instrument will activate overload protection and prompt a warning. Switch off the instrument, ensure the test body is not charged, disconnect cables, and then restart.
  • No Saved Data: If the "View" screen shows "No saved data!", it means no test results have been stored yet. Perform tests and save them.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the instrument. Do not use abrasive cleaners or solvents.
  • Storage: Store the instrument in a cool, dry place, away from direct sunlight and extreme temperatures (-20℃ to 60℃, below 70%rh humidity).
  • Battery Care: Charge the battery regularly, especially if the instrument will be stored for an extended period, to maintain battery health.
  • Cable Inspection: Regularly inspect test cables for any signs of damage, such as cuts or exposed wires. Replace damaged cables immediately.
  • Calibration: Calibration and maintenance should only be performed by authorized and qualified personnel.

8. User Tips

  • The ES6030 TTR Tester is versatile and can be used for current transformers (CT) in addition to power transformers.
  • Always ensure proper connection of test leads to avoid errors and ensure safety.
  • Utilize the data storage feature to keep a record of your measurements for analysis and reporting.
  • For complex setups or specific transformer types, refer to the detailed wiring diagrams provided in the manual.

9. Packing List

ItemQuantityDetails
Instrument1 pcsES6030 TTR Turns Ratio Tester
Test line2 groupsRed/black, each 10 meters/group
CD1 pcsContains USB driver and PC software
Data cable1 pcsType-C, 1 meter
Charger1 pcs14.8V/1.5A
Introduction manual, warranty certification1 setUser manual and warranty documents
Parcel1 pcsCarrying case for the instrument and accessories
Image showing the complete packing list contents of the ES6030 TTR Turns Ratio Tester, including the device, test leads, charger, USB cable, CD, manual, and carrying bag.
Image showing the complete packing list contents of the ES6030 TTR Turns Ratio Tester, including the device, test leads, charger, USB cable, CD, manual, and carrying bag.

10. Warranty and Support

The contents of this user manual do not justify the use of the product for special purposes. We are not responsible for other damages caused by the use. The Company reserves the right to modify the contents of the user manual. In case of modification, no further notice will be given.

For support, please contact:

  • Manufacturer: Guangzhou Zhengneng Electronic Technology Co., Ltd.
  • Address: 4/F, No. 771, Guang Cong 8th Road, Changyao Ling Village, Zhongluotan Town, Baiyun District, Guangzhou, China
  • Tel: 86-13564525088
  • Email: harrybot@aliyun.com
  • Company website: www.fuzrr.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.