1. Safety Rules and Precautions
Thank you for purchasing our transformer turns ratio tester. Before you use the instrument for the first time, in order to avoid possible electric shock or personal injury, please be sure to: read in detail and strictly observe the safety rules and precautions listed in this manual.
In any case, special attention should be paid to safety when using this instrument.
- The instrument is designed, manufactured and tested in accordance with IEC61010 safety specifications.
- In any case, special attention should be paid to safety when using this instrument.
- Notice the labeled text and symbols on the body of this instrument.
- Before use, it should be confirmed that the instrument and accessories are intact, and the insulation of the instrument and test line is not broken exposed,No broken wires to use.
- During measurement, it is strictly prohibited to touch the exposed conductors and the circuit being measured.
- Verify that the wire connection plugs are tightly inserted into the instrument connector.
- Do not measure in flammable locations, sparks may cause an explosion.
- Discontinue use of the instrument if metal is exposed due to breakage of the housing or test cable during use.
- Do not place and store the instrument for a long time in a hot and humid place or under direct sunlight.
- Pay attention to the measurement range specified for this instrument and the environment in which it is used.
- The use, disassembly, calibration, and maintenance of this instrument must be carried out by authorized and qualified personnel.
- If continued use poses a danger due to this instrument, stop using it and seal it immediately deposit, to be handled by an authorized and qualified body.
- The "!" safety warning symbols in the instrument and in the manual must be strictly followed by the user in this manual.Allow for safe operation.
2. Introduction
ES6030 transformer turns ratio tester adopts microprocessor technology for measurement calculation and automatic control, which can quickly and easily measure the actual transformer ratio and group. It is mainly used in the power industry to measure the transformer ratio and group, and at the same time, it is used by transformer manufacturers and distributors to measure the transformer parameters.
ES6030 transformer ratio tester consists of host, monitoring software, test line, communication line and so on. The host has a charging function without the need to find power on site, full-colour large-screen LCD display, the language can choose Chinese or English, at a glance, touch-screen operation is convenient and easy to use, the port anti-overload function, large-capacity storage of 500 groups of data. Upper computer software with historical data reading, access, save and other functions.


3. Specifications
| Feature | Description |
|---|---|
| Function | Ratio and group testing of three-phase transformers, single-phase transformers, PT and CT. Blind testing of three-phase transformers, ratio and group testing of Z-type transformers. |
| Specimen Type | Single phase transformer, three phase transformers, Z-type transformers, PT, CT |
| Ratio Range | 0.9~10000 |
| Overload Protection | Yes |
| Power Source | DC9.6V 3800mAh high capacity lithium battery |
| Charging Function | Yes |
| Display Mode | 5-inch touchscreen (854x480 dots) full-color LCD display |
| Interactive Mode | Touch screen / buttons |
| LCD Size (L x W) | 108 mm x 65 mm |
| Instrument Size (L x W x H) | 229 mm x 166 mm x 74 mm |
| Mobile APP | Yes, Bluetooth connection |
| Computer Connect | Yes, USB cable connection |
| Data Storage | 500 groups |
| Data Access | Data access function |
| Battery Voltage | Real-time display, indicates need for timely charging when low. |
| Automatic Switch Off | Settable for 1~30 minutes. |
| Power Dissipation (Standby) | Approx. 2W (100% brightness) |
| Power Dissipation (Measurement) | 12W Max |
| Weight (Instrument) | 1.5kg (including battery) |
| Weight (Test Cables) | 1.7kg |
| Working Temperature & Humidity | -10℃~40℃; below 70%rh |
| Storage Temperature & Humidity | -20℃~60℃; below 70%rh |
| Insulation Resistance | Above 10 MΩ (500V between circuit and housing) |
| Pressure Resistance | AC 3700V/rms (between circuit and enclosure) |
| Electromagnetic Property | IEC61010-4-3, ratio frequency≤1V/m |
| Safety Regulation | IEC61010-1, CAT III 600V, pollution class 2 |
3.1. Range and Accuracy
| Measure the ratio range | Resolution ratio | Accuracy |
|---|---|---|
| 0.9 ≤ TTR < 10 | 0.0001 | ±0.2% ±2dgt |
| 10 ≤ TTR < 100 | 0.001 | ±0.2% ±2dgt |
| 100 ≤ TTR < 1000 | 0.01 | ±0.2% ±2dgt |
| 1000 ≤ TTR < 2000 | 0.1 | ±0.2% ±2dgt |
| 2000 ≤ TTR < 10000 | 0.1 | ±0.5% ±2dgt |
| 10000 ≥ TTR | 1 | -- |

4. Instrument Structure

4.1. Keypad and Ports Overview
- HV side A phase
- HV side B phase
- HV side C phase
- AV side A phase
- AV side B phase
- AV side C phase
- USB PORT
- Power button
- Confirmation key
- Return key
- Test key
- Color screen
- Multi-function key
- Right button
- Left button
- Down button
- Upper button
- Charging port
5. Method of Operation
5.1. Switching On and Off
Pressing the red "power button" in the off state will turn the power on, and pressing the red "power button" in the on state will turn the power off.
5.2. Interface Overview
The main interface provides access to different test modes and settings.

5.3. Iconography and Controls
The device features both silicone keypad buttons and a touch screen for interaction. Below is a guide to the main icons and their functions.
| Icon | Name | Note |
|---|---|---|
| ▲ | Upper key | Select upwards |
| ▼ | Down key | Select downwards |
| ◀ | Left key | Select to the left |
| ▶ | Right key | Select to the right |
| Multiplex key | Equivalent to touching the bottom left button of the screen, including deleting, saving, sound, etc. | |
| ⏻ | Power button | Switching power supply |
| ⏎ | Confirm key | Conform or checked. |
| ↩ | Return key | Return to the previous screen |
| TEST | Test key | Start testing |
Touch Button Icons
| Icon | Name | Note |
|---|---|---|
| OK | Confirm key | Conform or checked. |
| ↩ | Return key | Return to the previous screen |
| ▲ | Upper key | Select upwards |
| ▼ | Down key | Select downwards |
| ◀ | Left key | Select to the left |
| ▶ | Right key | Select to the right |
| 🗑️ | Delete key | Delete all the test records. |
| Time | Time key | Enter the set time interface |
| 🔇 | Sound key | Set the buzzer switch. |
| 🔊 | Sound key | Set the buzzer switch. |
| Save | Save key | Save the test record |
| BLE | Bluetooth key | Set up Bluetooth on or off. |
| EN/CN | Language switching | Switch between Chinese and English |
| TEST | Test key | Start testing |
Other Icons
| Icon | Note |
|---|---|
| 🔆 | Using for adjusting the brightness of the backlight. |
| 🔋 | Battery level display |
| 🔌 | Charging status display |
| 블루투스 아이콘 | Bluetooth is displayed in the upper right corner of the large screen when it is switched on. |
| 🔍 | View test record |
5.4. Battery Level Check
1. After power on, if the upper right corner of the big screen shows the low battery voltage symbol, it means the battery power is insufficient, please charge it in time. The battery power is sufficient to ensure the accuracy of measurement.
2. The power consumption during the test is higher than standby, if the LCD shows low battery voltage symbol during the test, it means that the battery power is about to be insufficient, please fill up the power in time. In order to ensure the accuracy of the test.
3. The power is not enough to support the test will automatically shut down, please charge and then test.
5.5. Single-Phase Transformer Test
5.5.1. Wiring Methods

5.5.2. Test Operation
In the main interface, click on the "Single phase test" icon to enter the resistance test setup interface. You can adjust the specimen number, rated high voltage (HV), rated low voltage, tap spacing, and rated tap. After setting the parameters, click "TEST" or press the silicone button "TEST" to start the test. The test result will be displayed on the screen.
5.6. Three-Phase Transformer Test
5.6.1. Wiring Methods

5.6.2. Test Operations
For conventional three-phase transformers with recognizable nameplates, click the "three phase test" icon and then "normal test". If the nameplate is not recognizable, choose "three-phase blind test". For Z-Type Transformers, click the "Z-Type Test" icon.
Similar to single-phase testing, you can adjust specimen number, rated HV, rated low voltage, tap spacing, and rated tap. The LINK GROUP contains three parameters: High-voltage side coupling methods (D, Y, YN, ZN, and unknown for blind testing) and Low-voltage side linkage (d, y, yn, and unknown). The "Auto" option is available for 3-phase blind tests.
After setting parameters, click "TEST" to begin. The test result will be displayed.
5.7. Settings
From the main interface, click the "Set" icon to access system settings. Here you can adjust:
- Backlight: Drag the icon left or right to adjust brightness.
- Shutdown Time: Set auto-shutdown from 1 to 30 minutes. The tester will power off automatically after this period of inactivity.
- Sound: Toggle the buzzer sound on/off.
- Language: Switch between Simplified Chinese and English.
- Bluetooth: Toggle Bluetooth on/off. When on, the Bluetooth icon will appear in the upper right corner of the screen.
- Time Setting: Enter the time setting interface to adjust year, month, day, hour, and second. Click "OK" to update.
5.8. Data Management
5.8.1. Data Storage
In the test result interface, click "Save" to store the test results. The tester can save up to 500 sets of test results. If storage is full, clear old records from the access screen before saving new data.
5.8.2. Data Access/Deletion
From the main interface, click the "View" icon to enter the access interface. If no data is saved, it will prompt "No saved data!". Use the left and right buttons to navigate pages, and the up and down buttons to select records. You can also directly click a record on the screen to view it. To delete records, use the "Delete" icon.
5.9. APP and PC Upper Computer Operation
The ES6030 supports connection to both Android APP and PC software.
5.9.1. PC Connection Instructions
Install the USB driver and host computer software from the provided CD-ROM. After switching on the instrument, connect it to the PC using the accessory USB cable. The software will automatically search for and connect to the port. Once connected, you can check historical data, generate Excel reports, and perform other operations.
5.9.2. Android APP Connection Instructions
Ensure your mobile phone or tablet runs Android 5.0 or above and has the TTR Tester APP installed. In the "Settings" page of the instrument, click the Bluetooth icon to turn on Bluetooth. Then, turn on the APP, search for the "TTR Tester" Bluetooth device, and connect. This enables wireless control measurement and data browsing.
6. Troubleshooting
- Low Battery: If the low battery voltage symbol appears, charge the instrument immediately to ensure accurate measurements. The instrument may automatically shut down if the battery is too low during testing.
- Overload Protection: If an overload is detected during pre-test checking, the instrument will activate overload protection and prompt a warning. Switch off the instrument, ensure the test body is not charged, disconnect cables, and then restart.
- No Saved Data: If the "View" screen shows "No saved data!", it means no test results have been stored yet. Perform tests and save them.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the instrument. Do not use abrasive cleaners or solvents.
- Storage: Store the instrument in a cool, dry place, away from direct sunlight and extreme temperatures (-20℃ to 60℃, below 70%rh humidity).
- Battery Care: Charge the battery regularly, especially if the instrument will be stored for an extended period, to maintain battery health.
- Cable Inspection: Regularly inspect test cables for any signs of damage, such as cuts or exposed wires. Replace damaged cables immediately.
- Calibration: Calibration and maintenance should only be performed by authorized and qualified personnel.
8. User Tips
- The ES6030 TTR Tester is versatile and can be used for current transformers (CT) in addition to power transformers.
- Always ensure proper connection of test leads to avoid errors and ensure safety.
- Utilize the data storage feature to keep a record of your measurements for analysis and reporting.
- For complex setups or specific transformer types, refer to the detailed wiring diagrams provided in the manual.
9. Packing List
| Item | Quantity | Details |
|---|---|---|
| Instrument | 1 pcs | ES6030 TTR Turns Ratio Tester |
| Test line | 2 groups | Red/black, each 10 meters/group |
| CD | 1 pcs | Contains USB driver and PC software |
| Data cable | 1 pcs | Type-C, 1 meter |
| Charger | 1 pcs | 14.8V/1.5A |
| Introduction manual, warranty certification | 1 set | User manual and warranty documents |
| Parcel | 1 pcs | Carrying case for the instrument and accessories |

10. Warranty and Support
The contents of this user manual do not justify the use of the product for special purposes. We are not responsible for other damages caused by the use. The Company reserves the right to modify the contents of the user manual. In case of modification, no further notice will be given.
For support, please contact:
- Manufacturer: Guangzhou Zhengneng Electronic Technology Co., Ltd.
- Address: 4/F, No. 771, Guang Cong 8th Road, Changyao Ling Village, Zhongluotan Town, Baiyun District, Guangzhou, China
- Tel: 86-13564525088
- Email: harrybot@aliyun.com
- Company website: www.fuzrr.com