Sako SUNON V

Sako 6.5kVA/6.2KW 48V MPPT Solar Hybrid Inverter User Manual

Model: SUNON V

Brand: Sako

1. Introduction

This manual provides essential information for the safe and efficient operation of your Sako 6.5kVA/6.2KW 48V MPPT Solar Hybrid Inverter. This advanced inverter is designed to manage power from solar panels, batteries, and the utility grid, providing a reliable and uninterrupted power supply for your home or application. It features a built-in 120A MPPT charge controller and pure sine wave output, capable of working with or without a battery.

Sako 6.5kVA/6.2KW 48V MPPT Solar Hybrid Inverter front view with key features highlighted

Figure 1: Front view of the Sako Hybrid Solar Inverter, highlighting features like 6200W 48V, 120A MPPT solar controller, 60-500VDC PV array voltage, ability to work without battery, BMS, and dual input.

2. Key Features

  • Built-in local WiFi for mobile monitoring (App is available).
  • OTG function for data event storage.
  • Optional RGB or movable LCD case design.
  • Reserved communication ports (RS485, CAN-BUS or RS232) for Battery Management System (BMS).
  • Battery independent design, allowing operation without a battery.
  • Battery equalization feature to extend battery life cycle.
  • Dual (Double) AC Output.
  • Enhanced power charging capabilities.
  • Built-in anti-dust kit for improved durability.
  • Hybrid functionality, capable of working as both off-grid and on-grid inverter.
Diagram illustrating main features of the Sako SUNON V Hybrid Solar Inverter

Figure 2: Diagram showing the main features of the SUNON V Hybrid Solar Inverter, including BMS, wide voltage range, dual smart & main load, work with/without battery, 120A max PV charging, hybrid (on/off grid), anti-dust kit, and Wifi monitor.

3. Setup and Installation

Proper installation is crucial for the safe and optimal performance of your inverter. It is recommended that installation be performed by a qualified electrician or solar professional.

3.1 Mounting

Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure sufficient clearance around the unit for proper airflow. The inverter is designed for wall mounting.

Sako inverter installed on a wall in a home setting

Figure 3: Example of the Sako inverter installed on a wall, demonstrating a typical home setup with an optional battery unit.

3.2 Electrical Connections

Refer to the connection ports on the rear of the inverter for wiring. Ensure all connections are secure and correctly polarized. Use appropriate gauge wiring for all connections to prevent overheating and ensure efficient power transfer.

  • PV Input: Connect your solar panel array to the PV IN+ and PV IN- terminals. The inverter supports a wide PV array voltage range of 60-500VDC.
  • Battery Connection: Connect your 48V battery bank to the designated battery terminals. The inverter supports BMS communication via RS485, CAN-BUS, or RS232 ports.
  • AC Input: Connect the utility grid AC power to the AC INPUT terminals. An input breaker is provided.
  • AC Output: Connect your loads to the Dual AC OUTPUT 1 and AC OUTPUT 2 terminals.
  • Communication Ports: Utilize USB, RS232, RS485 (BMS), WiFi, and Dry-contact ports for monitoring and advanced control.
Rear view of the Sako inverter showing all connection ports

Figure 4: Rear view of the Sako inverter, detailing connection points for NC C NO, USB, BMS, COM PORT, AC OUTPUT 1, AC OUTPUT 2, INPUT BREAKER, PV IN+, and PV IN-.

Warning: Incorrect wiring can cause damage to the inverter, batteries, and connected appliances, and poses a risk of electric shock. Always consult the full wiring diagram and safety guidelines before making any connections.

4. Operation

4.1 Powering On/Off

Once all connections are made and verified, switch on the input breaker. The inverter's LCD display will illuminate, showing system status and operational parameters.

4.2 LCD Display and Controls

The inverter features an intuitive LCD display and control buttons for monitoring and configuration. The display provides real-time information on PV input, AC output, battery status, and load. Use the navigation buttons to cycle through different screens and adjust settings.

Video 1: Demonstration of the inverter's LCD display showing real-time operational data, along with measurements of current and noise levels during operation.

4.3 Charging Modes

The inverter offers user-configurable AC/Solar Charging modes and Load Output modes to optimize power usage. You can select from four primary charging modes:

  1. Solar Charging: Prioritizes solar power for charging batteries and powering loads.
  2. Electricity Utility Priority: Prioritizes utility grid power.
  3. Solar Priority: Prioritizes solar power, using utility only when solar is insufficient.
  4. Hybrid Charging: Combines solar and utility power for optimal charging and load support.
Diagram showing the four charging modes of the Sako inverter

Figure 5: Illustration of the four user-configurable charging modes: Solar Charging, Electricity Utility Priority, Solar Priority, and Hybrid Charging.

4.4 Uninterrupted Power Supply (UPS)

The inverter is designed to provide 24/7 uninterrupted power supply. During the day, it charges batteries using solar power and supplies power to loads. During the night, it discharges the battery to power loads, seamlessly switching to utility power if the battery is depleted or solar input is unavailable.

Diagram illustrating 24/7 uninterrupted power supply with daytime charging and nighttime discharge

Figure 6: Diagram showing the inverter's capability for 24/7 uninterrupted power supply, with solar charging during the day and battery discharge at night.

4.5 Mobile Monitoring

Utilize the built-in WiFi and the available mobile application for remote monitoring of your inverter's performance and system status.

5. Maintenance

The Sako Hybrid Inverter is designed for minimal maintenance. However, regular checks can ensure its longevity and optimal performance.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Do not use liquid cleaners.
  • Ventilation: Ensure that the ventilation openings are clear of dust and debris to prevent overheating. The built-in anti-dust kit helps reduce dust accumulation.
  • Connections: Annually check all electrical connections for tightness and signs of corrosion.
  • Battery Health: If using batteries, monitor their health and ensure the battery equalization feature is active to extend their lifespan.

6. Troubleshooting

This section provides general guidance for common issues. For complex problems, please contact customer support.

  • No Power Output: Check input power from solar panels and utility grid. Verify battery connections and charge level. Ensure all breakers are in the ON position.
  • Inverter Overheating: Check for obstructions around ventilation openings. Ensure the ambient temperature is within the specified operating range.
  • Error Codes: Refer to the inverter's LCD display for specific error codes. Consult the detailed product manual (if available) or contact support with the error code for assistance.

7. Specifications

Below are the detailed technical specifications for the Sako SUNON V 6.5kVA/48V Hybrid Solar Inverter:

Technical parameter table for Sako SUNON V 6.5KVA/48V inverter

Figure 7: Part 1 of the detailed technical parameter table for the Sako SUNON V 6.5KVA/48V inverter.

Continuation of the technical parameter table for Sako SUNON V 6.5KVA/48V inverter

Figure 8: Part 2 of the detailed technical parameter table for the Sako SUNON V 6.5KVA/48V inverter.

ParameterValue
Model NumberSunon V
Rated Power6500VA/6200W
Output Voltage (V)48V
ApplicationHome
CertificationCE, RoHS
OriginMainland China
AC Output Voltage230 VAC ± 5%
Frequency50Hz/60Hz (Auto sensing)
Dimensions (D×W×H)583 × 380 × 214mm
Net Weight10.4 kg
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C
Humidity5%-95% RH (Non-condensing)
Communication InterfaceUSB/RS232/RS485(BMS)/WiFi/Dry-contact

8. User Tips

  • Noise Consideration: The inverter operates with a measured noise level of approximately 48-51 dB at a distance. Consider its placement in your home or installation area to minimize potential noise disturbance.
  • Battery-less Operation: This inverter can function without a battery, directly utilizing solar and/or grid power. Ensure your system configuration is set appropriately for this mode if you choose not to use a battery.
  • Monitoring App: Take advantage of the mobile monitoring app to keep track of your system's performance and energy generation/consumption from anywhere.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or authorized service center. Keep your purchase records handy when contacting support.

Related Documents - SUNON V

Preview SAKO Solar Inverters, Batteries, and Energy Storage Systems - Product Catalog
SAKO offers a comprehensive range of solar inverters (on-grid, off-grid, hybrid), LiFePO4 lithium batteries, and integrated energy storage systems for residential and commercial use. Discover detailed product specifications and solutions for renewable energy.
Preview SAKO Inverter Error 08 Troubleshooting Guide: Bus Voltage Too High
Troubleshooting guide for SAKO inverters (SUNSEE, SUNON, SUNON PLUS, SUNPOLO) experiencing Error Code 08, indicating high bus voltage. Provides step-by-step instructions to diagnose and resolve the issue, including circuit testing and component identification.
Preview SAKO Inverter Troubleshooting Guide: Error Code 05
Detailed troubleshooting steps for SAKO inverters encountering error code 05, which signifies output short-circuit or over-temperature issues. Includes circuit diagram descriptions and component identification.
Preview SAKO Solar Inverters, Batteries, and Energy Storage Systems | Product Catalog
Explore SAKO's comprehensive range of solar inverters, lithium batteries, and energy storage systems, designed for efficient and reliable power solutions. View technical specifications and product details.
Preview SAKO Inverter Error 52 Troubleshooting Guide: Low Bus Voltage
Comprehensive guide to troubleshooting error code 52 on SAKO inverters (SUNSEE, SUNON, SUNON PLUS, SUNPOLO), focusing on low bus voltage issues and component testing.
Preview Troubleshooting Error 07 for SAKO Inverters
Guide to troubleshooting error code 07 (Overload time out) for SAKO SUNSEE, SUNON, SUNON PLUS, and SUNPOLO inverters. Includes steps to test the output sampling circuit.