1. Introduction
This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Features
- Pure sine wave inverter
- Programmable supply priority for PV, battery or Grid
- High PV input voltage range (55~450VDC)
- Built-in Max 110A MPPT solar charge
- Compatible with lithium-ion battery
- Support BMS communication with Lithium battery
- Smart battery charge design to optimize battery life
- Overload, high temperature, inverter output short circuit protection
- Cold start function
- Intelligent fan speed adjustment
- WIFI (Optional)
Basic System Architecture
The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system: Generator or Utility, PV modules (option).
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
- CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- GROUNDING INSTRUCTIONS -This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Product Overview
The SUMRY Hybrid Solar Inverter features a clear LCD display, status indicators, and function buttons for easy operation and monitoring. Key components include AC input/output, PV input, battery input, and communication ports.

Components Description:
- LCD display
- Status Indicator
- Charging Indicator
- Fault Indicator
- Function buttons
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- RS-232/RS485 communication port
- Safety (Earth) ground
4. Installation
4.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package: The unit x 1, User manual x 1.
4.2 Preparation
Before connecting all wirings, please take off bottom cover by removing two screws.
4.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

4.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in below table as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size as below.
Recommended battery cable and terminal size:
| Model | Wire Size | Cable mm² | Ring Terminal D (mm) | Ring Terminal L (mm) | Torque Value |
|---|---|---|---|---|---|
| 3.8KW 24V | 1*3AWG | 22 | 6.4 | 33.2 | 2 Nm |
| 6.2KW 48V | 1*4AWG | 22 | 6.4 | 33.2 | 2 Nm |
Please follow below steps to implement battery connection:
- Assemble battery ring terminal based on recommended battery cable and terminal size.
- Connect all battery packs as units requires.

3. Insert the ring terminal of battery cable flatly into battery connector of inverter and make sure the bolts are tightened with torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charger is correctly connected and ring terminals are tightly screwed to the battery terminals.

WARNING: Shock Hazard Installation must be performed with care due to high battery voltage in series.
CAUTION!! Do not place anything between the flat part of the inverter terminal and the ring terminal. Otherwise, overheating may occur.
CAUTION!! Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
4.5 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is for 32A for 3.8KW, 50A for 6.2KW.
CAUTION!! There are two terminal blocks with “IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested cable requirement for AC wires:
| Model | Gauge | Torque Value |
|---|---|---|
| 3.8KW | 12 AWG | 1.2~ 1.6 Nm |
| 6.2KW | 8 AWG | 1.4~ 1.6Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
L→LINE (brown or black)
N→Neutral (blue)
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
4. Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
L→LINE (brown or black)
N→Neutral (blue)
5. Make sure the wires are securely connected.
CAUTION: Important Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are worked in parallel operation.
CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay function before installation. Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.
4.6 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested cable requirement for PV wires:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.8KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 3.8KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 450Vdc | 450Vdc |
| PV Array MPPT Voltage Range | 55Vdc~450Vdc | 55Vdc~450Vdc |
Take 250Wp PV module as an example. After considering above two parameters, the recommended module configurations are listed as below table.
| Solar Panel Spec. (reference) | SOLAR INPUT (Min in serial: 6 pcs, max. in serial: 12 pcs) | Q'ty of panels | Total input power |
|---|---|---|---|
| 250Wp, Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60 | 2 pcs in serial | 2 pcs | 500W |
| 6 pcs in serial | 6 pcs | 1500W | |
| 8 pcs in serial | 8 pcs | 2000W | |
| 12 pcs in serial | 12 pcs | 3000W | |
| 13 pcs in serial | 13 pcs | 3250W | |
| 8 pieces in serial and 2 sets in parallel | 16 pcs | 4000W | |
| 10 pieces in serial and 2 sets in parallel | 20 pcs | 5000W |
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.


3. Make sure the wires are securely connected.
4.7 Final Assembly
After connecting all wirings, put the bottom cover back by screwing two screws.
5. Operation
5.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
5.2 Operation and Display Panel
The operation and display panel, shown below, is on the front panel of the inverter. It includes three indicators, four function keys and an LCD display, indicating the operating status and input/output power information.

LED Indicator:
| LED Indicator | Color | State | Messages |
|---|---|---|---|
| AC/INV | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3 LCD Display Icons
The LCD display provides various icons to indicate input source, configuration, output information, and battery status.

Input Source Information:
| Icon | Function description |
|---|---|
| AC | Indicates the AC input. |
| PV | Indicates the PV input. |
| 888.8 | Indicate input voltage, input frequency, PV voltage, battery voltage and charger current. |
Configuration Program and Fault Information:
| Icon | Function description |
|---|---|
| 88 | Indicates the setting programs. |
| 88.8 | Indicates the warning and fault codes. |
| Warning: 88.8 (flashing) | Flashing with warning code. |
| Fault: 88.8 (lighting) | Lighting with fault code. |
Output Information:
| Icon | Function description |
|---|---|
| 888.8 | Indicate output voltage, output frequency, load percent, load in VA, load in Watt and discharging current. |
Battery Information:
| Icon | Function description |
|---|---|
| CHARGING | Indicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery mode and charging status in line mode. |
In AC mode, it will present battery charging status.
| Status | Battery voltage | LCD Display |
|---|---|---|
| Constant Current mode | <2V/cell | 4 bars will flash in turns. |
| 2 ~ 2.083V/cell | Bottom bar will be on and the other three bars will flash in turns. | |
| Constant Voltage mode | 2.083 ~ 2.167V/cell | Bottom two bars will be on and the other two bars will flash in turns. |
| > 2.167 V/cell | Bottom three bars will be on and the top bar will flash. | |
| Floating mode | Batteries are fully charged. | 4 bars will be on. |
In battery mode, it will present battery capacity.
| Load Percentage | Battery Voltage | LCD Display |
|---|---|---|
| Load >50% | < 1.717V/cell | |
| 1.717V/cell ~ 1.8V/cell | ||
| 1.8 ~ 1.883V/cell | ||
| > 1.883 V/cell | ||
| 50%> Load > 20% | < 1.817V/cell | |
| 1.817V/cell ~ 1.9V/cell | ||
| 1.9 ~ 1.983V/cell | ||
| > 1.983 | ||
| Load < 20% | < 1.867V/cell | |
| 1.867V/cell ~ 1.95V/cell | ||
| 1.95 ~ 2.033V/cell | ||
| > 2.033 |
Load Information:
| Icon | Function description |
|---|---|
| Overload | Indicates overload. |
| Load Level (0-100%) | Indicates the load level by 0-24%, 25-50%, 50-74% and 75-100%. |
Mode Operation Information:
| Icon | Function description |
|---|---|
| Mains connection | Indicates unit connects to the mains. |
| PV panel connection | Indicates unit connects to the PV panel. |
| BYPASS | Indicates load is supplied by utility power. |
| Utility charger | Indicates the utility charger circuit is working. |
| DC/AC inverter | Indicates the DC/AC inverter circuit is working. |
Mute Operation:
| Icon | Function description |
|---|---|
| Mute | Indicates unit alarm is disabled. |
5.4 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" button to select setting programs. And then, press "ENTER" button to confirm the selection or ESC button to exit.
Setting Programs:
| Program | Description | Selectable option |
|---|---|---|
| 00 | Exit setting mode | Escape (00 ESC) |
| 01 | Output source priority: To configure load power source priority |
|
| 02 | Maximum charging current: To configure total charging current for solar and utility chargers. (Max. charging current = utility charging current + solar charging current) | 10A, 20A, 30A, 40A, 50A, 60A, 70A, 80A (default), 90A, 100A, 110A |
| 03 | AC input voltage range |
|
| 04 | Power saving mode enable/disable |
|
| 05 | Battery type |
|
| 06 | Auto restart when overload occurs |
|
| 07 | Auto restart when over temperature occurs |
|
| 08 | Output voltage |
|
| 09 | Output frequency |
|
| 11 | Maximum utility charging current | 10A, 20A, 30A, 40A, 50A, 60A, 70A, 80A |
| 12 | Setting voltage point back to utility source when selecting "SBU priority" | Available options in 24V models: 22.0V, 22.5V, 23.0V (default), 23.5V, 24.0V, 24.5V, 25.0V, 25.5V. Available options in 48V models: 44V, 45V, 46V (default), 47V, 48V, 49V, 50V, 51V. |
| 13 | Setting voltage point back to battery mode when selecting "SBU priority" | Available options in 24V models: Battery fully charged, 24V, 24.5V, 25V, 25.5V, 26V, 26.5V, 27V (default), 27.5V, 28V, 28.5V, 29V. Available options in 48V models: Battery fully charged, 48V, 49V, 50V, 51V, 52V, 53V, 54V (default), 55V, 56V, 57V, 58V. |
| 16 | Charger source priority: To configure charger source priority |
|
| 18 | Alarm control |
|
| 19 | Auto return to default display screen |
|
| 20 | Backlight control |
|
| 22 | Beeps while primary source is interrupted |
|
| 23 | Overload bypass: When enabled, the unit will transfer to line mode if overload occurs in battery mode. |
|
| 25 | Record Fault code |
|
| 26 | Bulk charging voltage (C.V voltage) | 24V model default setting: 28.2V. 48V model default setting: 56.4V. If user-defined battery type is selected (program 05), setting range is from 24.0V to 29.2V for 24V model and 48.0V to 58.4V for 48V model. Increment of each click is 0.1V. 24V model default to 27.0V. |
| 27 | Floating charging voltage | 48V model default setting: 54.0V. If user-defined battery type is selected (program 05), setting range is from 24.0V to 29.2V for 24V model, 48.0V to 58.4V for 48V model. Increment of each click is 0.1V. |
| 29 | Low DC cut-off voltage | 24V model default setting: 21.0V. 48V model default setting: 42.0V. If user-defined battery type is selected (program 05), setting range is from 20.0V to 24.0V for 24V model, 40.0V to 48.0V for 48V model. Increment of each click is 0.1V. Low DC cut-off voltage will be fixed to setting value no matter what percentage of load is connected. |
| 31 | Solar power balance: When enabled, solar input power will be automatically adjusted according to connected load power |
|
| 33 | Battery equalization | If "Flooded" or "User-Defined" is selected in program 05, this program can be set up. |
| 34 | Battery equalization voltage | 3.8KW default setting: 29.2V. 6.0KW default setting: 58.4V. Setting range is from 24V to 29.5V (24V models) and 50V to 59V (48V models). Increment of each click is 0.1V. |
| 35 | Battery equalized time | 60min (default). Setting range is from 5min to 900min. Increment of each click is 5min. |
| 36 | Battery equalized timeout | 120min (default). Setting range is from 5min to 900 min. Increment of each click is 5 min. |
| 37 | Equalization interval | 30days (default). Setting range is from 0 to 90 days. Increment of each click is 1 day. |
| 39 | Equalization activated immediately |
|
5.5 Display Setting
The LCD display information will be switched in turns by pressing "UP" or "DOWN" key. The selectable information is switched as below order: input voltage, input frequency, PV voltage, MPPT charging current, MPPT charging power, battery voltage, output voltage, output frequency, load percentage, load in VA, load in Watt, DC discharging current, main CPU Version and second CPU Version.
Selectable information and LCD display:
| Selectable information | LCD display |
|---|---|
| Input voltage/Output voltage (Default Display Screen) | Input Voltage=230V, output voltage=230V |
| Input frequency | Input frequency=50Hz |
| PV voltage | PV voltage=360V |
| MPPT Charging current | Current ≥ 10A or Current < 10A |
| MPPT Charging power | MPPT charging power=500W |
| Battery voltage/ DC discharging current | Battery voltage=25.5V, discharging current=1A |
| Output frequency | Output frequency=50Hz |
| Load percentage | Load percent=70% |
| Load in VA | When connected load is lower than 1kVA, load in VA will present xxxVA. When load is larger than 1kVA, load in VA will present x.xkVA. |
| Load in Watt | When load is lower than 1kW, load in W will present xxxW. When load is larger than 1kW, load in W will present x.xkW. |
| Main CPU version checking | Main CPU version SR 26.00 |
5.6 Operating Mode Description
| Operation mode | Description | LCD display |
|---|---|---|
| Standby mode / Power saving mode | No output is supplied by the unit but it still can charge batteries. | Charging by utility and PV energy. Charging by utility. Charging by PV energy. No charging. |
| Fault mode | Errors are caused by inside circuit error or external reasons such as over temperature, output short circuited and so on. PV energy and utility can charge batteries. | Charging by utility and PV energy. Charging by utility. Charging by PV energy. No charging. |
| Line Mode | The unit will provide output power from the mains. It will also charge the battery at line mode. | Charging by utility and PV energy. Charging by utility. |
| Battery Mode | The unit will provide output power from battery and PV power. | Power from battery and PV energy. Power from battery only. |
5.7 Battery Equalization Description
Equalization function is added into charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize battery periodically.
How to Apply Equalization Function:
You must enable battery equalization function in monitoring LCD setting program 33 first. Then, you may apply this function in device by either one of following methods:
- Setting equalization interval in program 34.
- Active equalization immediately in program 39.
When to Equalize:
In float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter Equalize stage.
Equalize charging time and timeout:
In Equalize stage, the controller will supply power to charge battery as much as possible until battery voltage raises to battery equalization voltage. Then, constant-voltage regulation is applied to maintain battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until setting battery equalized time is arrived.
However, in Equalize stage, when battery equalized time is expired and battery voltage doesn't rise to battery equalization voltage point, the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage. If battery voltage is still lower than battery equalization voltage when battery equalized timeout setting is over, the charge controller will stop equalization and return to float stage.
6. Troubleshooting
6.1 Fault Reference Code:
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when inverter is off. | 01 |
| 02 | Over temperature | 02 |
| 03 | Battery voltage is too high | 03 |
| 04 | Battery voltage is too low | 04 |
| 05 | Output short circuited or over temperature is detected by internal converter components. | 05 |
| 06 | Output voltage is too high. | 06 |
| 07 | Overload time out | 07 |
| 08 | Bus voltage is too high | 08 |
| 09 | Bus soft start failed | 09 |
| 11 | Main relay failed | 11 |
| 51 | Over current or surge | 51 |
| 52 | Bus voltage is too low | 52 |
| 53 | Inverter soft start failed | 53 |
| 55 | Over DC voltage in AC output | 55 |
| 56 | Battery connection is open | 56 |
| 57 | Current sensor failed | 57 |
| 58 | Output voltage is too low | 58 |
6.2 Warning Indicator:
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is over-charged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 12 | Solar charger stops due to low battery. | 12 | |
| 13 | Solar charger stops due to high PV voltage. | 13 | |
| 14 | Solar charger stops due to overload. | 14 |
6.3 Troubleshooting Guide:
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Battery polarity is connected reversed. | 1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS→Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Buzzer beeps continuously and red LED lights up. | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 05 | Temperature of internal converter component is over 120°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 02 | Internal temperature of inverter component is over 100°C. | Return to repair center. | |
| Fault code 03 | Battery is over-charged. | Check if spec and quantity of batteries meet requirements. | |
| The battery voltage is too high. | Replace the fan. | ||
| Fault code 01 | Fan fault | 1. Reduce the connected load. 2. Return to repair center. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | Return to repair center. | |
| Fault code 08/09/53/57 | Internal components failed. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 51 | Over current or surge. | If the battery is connected well, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. | ||
| Fault code 56 | Battery is not connected well or fuse is burnt. |
7. Specifications
The SUMRY SP Series Hybrid Solar Inverter is available in various models, each with specific technical parameters to suit different power requirements. Below are the detailed specifications for Line Mode, Inverter Mode, Charge Mode, and General Specifications.

7.1 Line Mode Specifications:
| INVERTER MODEL | 3.8KW 24V | 6.2KW 48V |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
7.2 Inverter Mode Specifications:
| INVERTER MODEL | 3.8KW 24V | 6.2KW 48V |
|---|---|---|
| Rated Output Power | 4.2KVA/3.8KW | 7.0KVA/6.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 60Hz or 50Hz | |
| Peak Efficiency | 94% | |
| Overload Protection | 5s@≥150% load; 10s@110%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc |
| Low DC Warning Voltage @load < 20% | 22.0Vdc | 44.0Vdc |
| @20% ≤ load < 50% | 21.4Vdc | 42.8Vdc |
| @load ≥ 50% | 20.2Vdc | 40.4Vdc |
| Low DC Warning Return Voltage @load < 20% | 23.0Vdc | 46.0Vdc |
| @20% ≤ load < 50% | 22.4Vdc | 44.8Vdc |
| @load ≥ 50% | 21.2Vdc | 42.4Vdc |
| Low DC Cut-off Voltage @load < 20% | 21.0Vdc | 42.0Vdc |
| @20% ≤ load < 50% | 20.4Vdc | 40.8Vdc |
| @load ≥ 50% | 19.2Vdc | 38.4Vdc |
| High DC Recovery Voltage | 29Vdc | 58Vdc |
| High DC Cut-off Voltage | 31Vdc | 62Vdc |
| No Load Power Consumption | <25W | <50W |
| Saving Mode Power Consumption | <10W | <15W |
7.3 Charge Mode Specifications:
Utility Charging Mode:
| INVERTER MODEL | 3.8KW 24V | 6.2KW 48V |
|---|---|---|
| Charging Current (UPS) @Nominal Input Voltage | 80A | 80A |
| Bulk Charging Voltage (Flooded Battery) | 29.2 | 58.4 |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2 | 56.4 |
| Floating Charging Voltage | 27Vdc | 54Vdc |
| Charging Algorithm | 3-Step | |
Solar Charging Mode:
| INVERTER MODEL | 3.8KW 24V | 6.2KW 48V |
|---|---|---|
| Rated Power | 6000W | 6000W |
| PV Charge Current | 110A | 110A |
| Efficiency | 98.0% max. | |
| Max. PV Array Open Circuit Voltage | 450Vdc | |
| PV Array MPPT Voltage Range | 55-450Vdc | |
| Min battery voltage for PV charge | ||
| Standby Power Consumption | 2W | |
| Battery Voltage Accuracy | +/-0.3% | |
| PV Voltage Accuracy | +/-2V | |
| Charging Algorithm | 3-Step | |
7.4 General Specifications:
| INVERTER MODEL | 3.8KW 24V | 6.2KW 48V |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | 0°C to 55°C | |
| Storage temperature | -15°C~60°C | |
| Dimension (D*W*H), mm | 423.4*290.4*100.7(mm) | 423.4*290.4*115.7(mm) |
| Net Weight, kg | 6.8KG | 7.8KG |
8. User Tips
- Battery Requirement: The SUMRY SP Series Hybrid Solar Inverter requires a connected battery to operate. It cannot function without a battery.
- WIFI Monitoring: For remote monitoring, ensure you download the SmartESS app for iOS or Android using the provided QR codes.
- Inductive Loads: For running inductive loads for extended periods, it is recommended to use a pure sine wave inverter.
- Sizing: Ensure the inverter's power rating is higher than the appliance you intend to power (at least 10% to 20% more than the maximum load). If running multiple appliances simultaneously, refer to the total wattage.
9. Frequently Asked Questions (FAQ)
- Q: Does this inverter work without batteries?
- A: No, the SUMRY SP Series Hybrid Solar Inverter requires a battery to operate. It must run with a connected battery.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your local SUMRY dealer or authorized service center. Keep your purchase receipt and product serial number handy for all support requests.
A user manual in PDF format is available for download: User Manual (PDF)