1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of your new Shower Floor Drain Backflow Preventer. Designed to prevent water backflow and eliminate unpleasant odors, this device ensures a clean and hygienic bathroom environment. Please read all instructions carefully before use to ensure safe and effective performance.
2. Safety and Warnings
Important Safety Information
Read all instructions before use. Failure to follow these instructions may result in damage to the product or personal injury.
- ATTENTION: Not suitable for children under 3 years old.
- ATTENTION: Keep the device and its cord out of reach of children under 3 years old.
- ATTENTION: Keep away from children unless supervised by an adult.
- ATTENTION: Do not use this product for purposes other than its intended use.
- ATTENTION: Inspect the product before each use; do not use if damaged.
- ATTENTION: Follow installation and operation guidelines to avoid injury.
- ATTENTION: Do not expose to water or moisture.
- ATTENTION: Handle with care to avoid cuts or injuries.
3. Product Overview
The Shower Floor Drain Backflow Preventer is designed with a gravity-activated mechanism to ensure one-way water flow and prevent odors and pests from entering your living space. It is constructed from durable brass with a polished finish, ensuring longevity and rust resistance.
4. Specifications
| Feature | Description |
|---|---|
| Material | Brass (ABS raw material for internal components) |
| Finish Type | Polish |
| Special Feature | Rustproof, Anti-Odor, Backflow Prevention |
| Style | Modern |
| Application | Sink, Shower, Bathtub Drains |
| Installation Caliber | 33-39mm / 1.3-1.54 inches |
| Floor Drain Method | Deodorization Type (Magnetic force + gravity direct discharge) |
| Dimensions (Approximate) | Top Diameter: 42mm, Height: 33mm, Bottom Diameter: 32mm |
5. Setup and Installation
The backflow preventer is designed for easy, plug-and-play installation. Follow these steps:
- Measure the Drain Hole: Before installation, carefully measure the inner diameter of your floor drain hole. The installation caliber of this product is 33-39mm (1.3-1.54 inches).
- Select Appropriate Core: Select the appropriate inner core (backflow preventer) according to the size of the hole. Ensure it fits snugly.
- Insert into Drain: Gently insert the backflow preventer into the drain hole. It should slide in easily. Do not force it if it doesn't fit.
- Installation in PVC Pipeline: If installing into a PVC pipeline, ensure the outer diameter of the pipe is approximately 40mm (as shown in Figure 6). The preventer is designed to fit within this range.
6. Operating Instructions
The backflow preventer operates automatically based on water flow and gravity.
- Drainage: When water flows into the drain, the gravity-activated flap opens, allowing water to pass through quickly and efficiently. The straight row design ensures rapid discharge.
- Backflow Prevention & Odor Sealing: When there is no water drainage, the flap automatically closes and seals, preventing backflow of water, odors, and pests (like insects and viruses) from rising up through the pipes.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your backflow preventer.
- Cleaning: Use a soft cloth to gently clean the surface of the visible parts. Do not use abrasive materials or harsh chemicals, as these can damage the finish and material.
- Inspection: Periodically inspect the device for any signs of damage or wear. Ensure the flap mechanism moves freely and seals properly.
- Hair and Debris: The design features a large opening to minimize hair hanging and cleaning needs. However, if you notice reduced drainage, remove the preventer and clear any accumulated hair or debris from the drain and the device itself.
- Storage: If removed for any reason, keep the device in a dry and ventilated area. Avoid long-term exposure to moisture and water.
- General Care: Keep away from sharp objects, high temperatures, and corrosive liquids.
8. Troubleshooting
If you encounter issues with your backflow preventer, refer to the following common solutions:
- Reduced Drainage: If water is draining slowly, the most common cause is accumulated hair or debris. Remove the backflow preventer from the drain and thoroughly clean both the drain pipe and the device. Reinsert the preventer, ensuring it is seated correctly.
- Persistent Odors: If odors persist, ensure the backflow preventer is installed correctly and the sealing ring is intact and properly positioned. Check for any gaps around the device where odors might escape. If the issue continues, inspect the drain pipe for blockages or damage further down the line.
- Backflow Occurring: If water is backing up, remove the preventer and check the flap mechanism. Ensure it is not obstructed by debris, preventing it from closing fully. Clean the flap and its hinge area. If the flap is damaged, the unit may need replacement.
- Improper Fit: If the preventer does not fit securely or is too loose/tight, re-measure your drain's inner diameter. Ensure you have selected the correct size for your drain.
9. User Tips
- For optimal odor prevention, ensure the sealing ring is always in place and free of damage.
- Regularly check the drain for hair accumulation, especially in showers, to maintain efficient drainage.
- The simple design allows for quick removal and re-insertion for cleaning, making maintenance hassle-free.
10. Manufacturer Information and Support
For any questions or support regarding your product, please contact the manufacturer or authorized representative:
Manufacturer:
Jinhua Jinwei Network Technology Co., LtdBuilding 2, No. 303 Qianfang Avenue, Xianhua Street,
Pujiang County, Jinhua City, Zhejiang Province, 322299, China
Email: contact@162mail.com
Phone: +86 2156980706
EU Authorized Representative:
SUCCESS COURIER SLCALLE RIO TORMES NUM.1, PLANTA 1, DERECHA, OFICINA 3,
Fuenlabrada, Madrid, Spain 28947
Email: successservice2@hotmail.com
Phone: +34 91060265