Sovol SH03 Filament Dryer 4 Spools

Contents

Sovol SH03 Filament Dryer 4 Spools Instruction Manual

Model: SH03 | Brand: Sovol

1. Introduction

The Sovol SH03 Filament Dryer is designed to effectively dry 3D printer filaments, preventing common printing issues such as clogging, bubbles, and poor layer adhesion caused by moisture. This device features dual independent heating chambers, an auto dehumidification system, and compatibility with various filament types, ensuring optimal printing results.

Sovol SH03 Filament Dryer with 4 spools
Figure 1: Sovol SH03 Filament Dryer with four spools of filament.

2. Safety Precautions

  • Read this manual carefully before operation.
  • Always disconnect the power supply when the device is not in use.
  • Avoid touching the shell near the air outlet during heating to prevent burns.
  • Do not allow children to operate the device without adult supervision.
  • Place the dryer on a flat, stable surface or platform to prevent it from falling.
  • If the power cord is damaged, it must be replaced by the manufacturer or its service agent to avoid hazards.
  • Do not place flammable or explosive materials inside the box.
  • The equipment circuit contains high-voltage parts. Do not attempt to disassemble or repair it yourself. If any abnormality occurs, contact customer support.
  • When the same parameters are set for both chambers simultaneously, slight differences in temperature display may occur.

3. Product Overview

The Sovol SH03 Filament Dryer features a user-friendly design with dual chambers and an intuitive control panel.

3.1 Components and Controls

Diagram of Sovol SH03 Filament Dryer components
Figure 2: Product diagram showing snap lock, screen, discharge hole, outlet, switch, and power cord interface.

The device includes:

  • Snap Lock: Secures the chamber covers.
  • Screen: Displays real-time monitoring data and settings.
  • Discharge Hole: For moisture release.
  • Outlet: Filament exit points.
  • Switch: Power on/off.
  • Power Cord Interface: For connecting the power supply.

3.2 Control Panel and Display

Sovol SH03 control panel and display explanation
Figure 3: Detailed view of the control panel and screen parameters.

The control panel features:

  • Buttons (from top to bottom): Chamber switching/Copy key, Setting selection key/Auto mode, Up, Down, Start/Pause.
  • Screen Parameters:
    • Relative Humidity: Displays the current humidity in the cavity.
    • Materials: Shows the selected consumable type.
    • Setting Temperature: Indicates the set temperature.
    • Current Temperature: Displays the real-time temperature in the cavity.
    • Time: Shows the countdown time.
    • Fan, Heating Module Working Status Icon: Indicates operational status.
    • Auto Mode Icon: Appears when Auto Mode is active.

4. Setup Instructions

4.1 Initial Power-Up

  1. Plug in the power cord of the drying box.
  2. Press the power switch located above the outlet to activate the drying box.

4.2 Loading Filament

  1. Open the top cover of the drying box.
  2. Place the filament spool(s) into the chamber(s). Ensure the filament is oriented correctly to avoid excessive friction with the filament hole.
  3. Close the top cover.
Diagram for installing PTFE tube and loading filament
Figure 4: Illustration of PTFE tube installation and proper filament loading to prevent feeding issues.

4.3 PTFE Tube Installation (Optional)

If filaments do not feed smoothly, you can install PTFE tubes:

  1. Remove the four sealing plugs from the top cover of the drying box.
  2. Install the Teflon tube to the air fitting.
  3. Insert the sharp end of the PTFE tube into the dry box cover by about 15mm.
  4. Pass the filaments through the Teflon tube from the inside.
  5. After use, remove and save the PTFE tubes for storage.

5. Operating Instructions

5.1 Basic Operation

  1. After connecting power and pressing the on/off button, the drying box automatically selects a chamber.
  2. Press the bottom Start/Pause button to begin drying with default parameters (e.g., PLA 50°C for 8 hours). Press again to pause.

5.2 Adjusting Parameters

  1. Switching Chambers: Short press the "Chamber switching/Copy key" (Chamber switching icon) to switch between inner chambers. Long press for 2 seconds to copy parameters from the current chamber to another.
  2. Selecting Parameters: Short press the "Setting selection key/Auto mode" (Setting selection icon) to cycle through parameters (e.g., Material, Setting Temperature, Time). The selected parameter will blink.
  3. Adjusting Values: Use the Up (Up arrow icon) and Down (Down arrow icon) keys to change the value of the blinking parameter.
  4. Confirming Settings: After adjusting, no operation is required. The system will automatically confirm settings if no input is detected for 10 seconds.

5.3 Auto Mode

Long press the "Setting selection key/Auto mode" (Setting selection icon) for 2 seconds to enter Auto Mode. The screen will display "AUTO".

  • In Auto Mode, the chamber monitors humidity. If below the set threshold, heating and fan stay off, and "--:--" appears.
  • If humidity exceeds the threshold, heating and fan activate with a 30-minute countdown, indicated by an icon.
  • The chamber continuously cycles between these states.
  • To exit Auto Mode, press and hold the "Setting selection key/Auto mode" until "AUTO" disappears.
Sovol SH03 Auto Moisture Removal and Auto Dry Mode
Figure 5: Explanation of Auto Moisture Removal and Auto Dry Mode functions.

The following table provides recommended drying temperatures and times for common filament types:

ConsumablesDrying TemperatureDrying Time
PLA50°C4-12h
PETG65°C4-8h
ABS80°C8-12h
TPU70°C4-8h
PVA50°C4-8h
ASA60°C8-12h
PA70°C≥12h
PP55°C4-8h
PC70°C8-12h
PET80°C8-12h

Note: When the drying box is working and the temperature inside the chamber reaches the preset target temperature, the intake and exhaust vents of the automatic dehumidifying module will open.

6. Maintenance and Care

6.1 Cleaning the Drying Box Interior

Remove residues from the chamber using a brush or a small vacuum cleaner (hoover).

6.2 Keeping the Workplace Clean

Ensure the area around the drying box is clean and free from dust and debris to prevent them from entering the drying chamber.

6.3 Desiccant Replacement

To replace the desiccant:

  1. Turn off the power and use your fingers to open the desiccant cover.
  2. Place new desiccant into the tank.
  3. Place the flap of the cover against its notch.
  4. Install the cover plate.
Diagram for desiccant replacement
Figure 6: Steps for replacing the desiccant in the drying box.

6.4 Environmental Precautions

Do not dispose of products as household waste. Follow local regulations for electronic waste disposal.

7. Troubleshooting

When an abnormality occurs, the drying box will sound a buzzer alarm and display an error code on the screen. The PTC heating block and fan will be shut down.

7.1 Exception Codes

  • F1: The fan rotates abnormally.
  • F2: Fan Disconnect.
  • H1: PTC heating block does not heat properly.
  • H2: PTC heating block heats uncontrollably.
  • N1: NTC thermistor short circuit.
  • N2: NTC thermistor is blocked.
  • A1: Intake Auto dehumidifying Module Malfunction.
  • A2: Exhaust vent Auto dehumidifying Module Malfunction.
  • G1: Temperature and humidity sensor reading abnormality.
  • G2: Temperature and humidity sensor communication abnormality.

Note: In the settings mode, press the "Chamber switching/Copy key" (Chamber switching icon) to select the chamber with the error code to eliminate the abnormal alarm status. If issues persist, contact customer support.

8. Specifications

ParameterValue
Input VoltageUS Regulations: 100-120V 60Hz; National Standard, British Standard, European Standard: 200-240V 50Hz
Rated Power400W
Filament Diameter1.75mm/2.85mm
Maximum Consumable CapacityPlace Two Rolls Of Consumables, Each Roll Is ≤70mm (Width) Or Place A Single Roll Of Consumables ≤150mm (Width)
Display Humidity Range0-99%
Display Temperature Range0-99°C
Work Temperature Range45°C-85°C
Machine Size (L*W*H)372mm * 288mm * 263mm
Equipment Weight3.4KG
Environmental Parameters5°C-40°C
Applicable FilamentPLA, ABS, PETG, TPU, PVA, ASA, PA, PP, PC, PET
Control MethodTouch
Assembly RequiredNo
Item ShapeRectangular

9. User Tips

  • The dual independent chambers allow for drying different filament types at different temperatures simultaneously, or one chamber for drying and another for sealed storage without power.
  • The dryer operates quietly, often quieter than other single-slot dryers.
  • The auto dehumidification system actively discharges moisture, which is a significant improvement over models that retain moisture.
  • Consider using longer PTFE tubes if you plan to print directly from the dryer, as the included ones are short.
  • While the unit is generally solid, some users report the lid latch can be tricky to close and button presses for auto mode may require multiple attempts.
  • The device heats up quickly, reaching 50°C in 4 minutes and 70°C in 12 minutes.
  • The power input voltage varies by region (100-120V 60Hz for US, 200-240V 50Hz for EU/UK). Ensure you have the correct version for your region.

10. Warranty and Support

For any abnormalities or issues not covered in the troubleshooting section, please contact Sovol customer support. You can find more information and contact details on the official website.

QR codes for Sovol Official User Group and Official Website
Figure 7: QR codes to join the Sovol Official User Group and visit the Official Website.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.